GULFSEMI SB180-E-41C

SB180-E-41C
SCHOTTKY BARRIER
RECTIFIER
VOLTAGE: 80V
CURRENT: 1.0A
FEATURE
DO-41
High current capability, Low forward voltage drop
Low power loss, high efficiency
High surge capability
High temperature soldering guaranteed
250°C /10sec/0.375" lead length at 5 lbs tension
Halogen Free
MECHANICAL DATA
Terminal: Plated axial leads solderable per
MIL-STD 202E, method 208C
Case: Molded with UL-94 Class V-0 Halogen Free Epoxy
Polarity: color band denotes cathode
Mounting position: any
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
(single-phase, half-wave, 60HZ, resistive or inductive load rating at 25°C, unless otherwise stated)
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC blocking Voltage
Maximum Average Forward Rectified Current 3/8" lead
length
Peak Forward Surge Current 8.3ms single half sinewave superimposed on rated load
Inrush Current with 10Ω and 20uF foil capacitor placed
in series to the DUT 10000 times, 10s between each
pulse
Tc=120℃
Maximum Forward Voltage at 1.0A DC
Maximum DC Reverse Current
Tc =25℃
at rated DC blocking voltage
Tc =100℃
Tc =120℃
Maximum Reverse Recovery Time(Note 1) Tc =25℃
Tc =120℃
Total power dissipatio
(Note2)
Typical Thermal Resistance
(Note 3)
(Note 4)
Storage and Operating Junction Temperature
SYMBOL
SB180-E-41C
units
Vrrm
Vrms
Vdc
80
56
80
1.0@ TL=100℃
0.5@ Tc=120℃
V
V
V
Ifsm
40.0
A
Ifsm-1
40min
A
Vf
0.84
0.5
1.5
4.0
V
If(av)
Ir
Trr
Ptot
Rth(ja)
Rth(jc)
Tj, Tstg
A
mA
2
5
840
50
30
-65 to +150
nS
mW
℃/W
℃
Note:
1.
2.
3.
4.
Rev.A1
Reverse Recovery Condition If =0.5A, Ir =1.0A, Irr =0.25A
Tc=25℃(according to calculations)
Thermal Resistance from Junction to Ambient at 0.5" lead length, vertical P.C. Board Mounted
Thermal Resistance from Junction to Case
www.gulfsemi.com
RATINGS AND CHARACTERISTIC CURVES SB180-E-41C
Rev.A1
www.gulfsemi.com
ESD CAPABILITY SB180-E-41C
1. According to 1.4601.442-01 test circuit, ESD Test of SB180-E at 80 Vdc passed with the
immunity capability of ±15KV
2. Description of test method & conditions
Setup:
Test voltages for DUT: max specified DC blocking voltage.
ESD test level for Contact discharge:
10 Impulses at each test level and output polarity.
Test level:±2,±4,±6,±8,±10,±12,±15KV
Test criteria:No faults are allowed.
Ambient temperature: 25℃
℃ Relative humidity : 55%
Specification: ESD Generator according to IEC 61000-4-2
( 1.4601.442-01 )
Rev.A1
www.gulfsemi.com