HB PL-IRM0101-3

INFRARED REMOTE CONTROL RECEIVER MODULE
PL-IRM0101-3
REV: B / 0
Package Dimensions
NOTES :
1. All dimensions are in millimeters.
2. Tolerance is ± 0.25(0.010") unless otherwise specified
DRAWING NO.: DS-27-01-0001
DATE: 2004-08-31
Page: 1
INFRARED REMOTE CONTROL RECEIVER MODULE
PL-IRM0101-3
REV: B / 0
Description
A miniaturized receiver for infrared remote control and IR data transmission.
PIN diode and preamplifier are assembled on lead frame.
The epoxy package is designed as IR filter.
The demodulated output signal can directly be decoded by a microprocessor. The main benefit is the
operation with high data rates and long distances.
Features
Photo detector and preamplifier in one package
Internal band filter for PCM frequency
Internal shielding against electrical field disturbance
TTL and CMOS compatibility
Output active low
Small size package
Special Features
Supply voltage 5.5 V
Short settling time after power on
High envelope duty cycle can be received
Enhanced immunity against disturbance from energy saving lamps
Application
AV instruments such as Audio, TV, VCR, CD, DVD, MD etc.
Home appliances such as Air conditioner, Fan etc.
The other equipments with wireless remote control.
CATV set top boxes.
Multi-media Equipment.
Sensors and light barrier systems for long distances
DRAWING NO.: DS-27-01-0001
DATE: 2004-08-31
Page: 2
INFRARED REMOTE CONTROL RECEIVER MODULE
PL-IRM0101-3
REV: B / 0
Block Diagram
VS
IN
AGC
&FILTER
INPUT
OUT
us
DEMODULATOR
AGC/ATC&DIGITAL CONTROL
OSCILLATOR
GND
Application Circuit
IRM
cc
DD
4.7u
≥2.4K
uC
GND
GND
Transmit Signal (Carrier Frequency=fo)
IR Transmitter
Output Wave Form
μ
μ
Delay
VOH
Output Pulse
Of Device
Twl
Twh
DRAWING NO.: DS-27-01-0001
VOL
DATE: 2004-08-31
Page: 3
INFRARED REMOTE CONTROL RECEIVER MODULE
PL-IRM0101-3
REV: B / 0
Data Transmission Rate, Vs=5V
5000
4000
3000
(bit/s)
2000
1500
1000
0
25.0
45.0
35.0
55.0
fo(KHz)
65.0
75.0
85.0
Illustration Of Used Terms
600us
IN
1
600us
8
8
tDON
tDOFF
8
600us
600us
OUT
ENVELOPE1
ENVELOPE2
ENVELOPE23
27600us/DATA WORD
OUT
DATA WORD
TELEGRAM PAUSE
DATA WORD
t
27.6ms
Trep=62ms
DRAWING NO.: DS-27-01-0001
DATE: 2004-08-31
Page: 4
INFRARED REMOTE CONTROL RECEIVER MODULE
PL-IRM0101-3
REV: B / 0
Absolute Maximum Ratings : ( Ta = 25°C )
Symbol
Parameter
Ultra Condition
Unit
5.5
V
Vcc
Supply Voltage
Tstg
Storage Temperature Range
-25to 85
℃
Topr
Operating Temperature Range
-25to 85
℃
Tsol
Soldering Temperature
255(Max 5sec)
℃
Lead Soldering Temperature {1.6mm(0.063inch)From Body}250±5℃ For 3 Seconds.
Electro-Optical Characteristics : ( Ta = 25℃)
Symbol
Parameter
Condition
Min.
Typ.
4.5
5
Max.
Unit
Vcc
Supply Voltage
Icc
Current Consumption
λP
Peak Emission Wavelength
940
nm
fo
B.P.F Center Frequency
38
KHz
L
Arrival Distance
0°
35
m
±45°
8
m
Input signal=0
L-514EIR1C
Voh
H Level Output Voltage
Vol
L Level Output Voltage
Twh
H Level Output Pulse Width
Burst Wave=600μs
Twl
L Level Output Pulse Width
Period=1.2ms
Output Form
30cm Over The Axis
V
2.5
4.5
mA
V
0.1
0.5
V
500
600
700
μs
500
600
700
μs
Active Low Output
Note 1.Distance between emitter & detector specifies maximum distance that output
waveform satisfies the standard under the conditions below against the standard
transmitter.
Measuring place------Indoors without extreme reflection of light.
Ambient light source------Detecting surface illumination shall be 200±50Lux under ordinary
fluorescence lamp of no high frequency lighting.
Standard transmitter------Burst wave indicated shall be arranged to 50mVp-p under the measuring
circuit.
Note 2. (Electro-optical chrematistics) shall be satisfied after leaving 2 hours in the
normal temperature.
DRAWING NO.: DS-27-01-0001
DATE: 2004-08-31
Page: 5
INFRARED REMOTE CONTROL RECEIVER MODULE
PL-IRM0101-3
REV: B / 0
Eemin/Ee-Rel.Responsivity
po-Output Pulse Width(ms)
Typical Characteristics(Ta=25℃)
λ=940nm
optical test signal,fig1
f/fo-Relative Frequency
Ee-Irradiance(mW/㎡)
Pulse Diagram
Eemin-Threshold Irradiance(mW/㎡)
1
λ=940nm
optical test signal,fig3
Ee-Irradiance(mW/㎡)
λ=940nm
E-Ambient DC Irradiance(mW/㎡)
Pulse Diagram
10KHz
1KHz
100KHz
△Vsrms-AC Voltage on DC Supply Voltage(mV)
DRAWING NO.: DS-27-01-0001
4
Eemin-Threshold Irradiance(mW/㎡)
Eemin-Threshold Irradiance(mW/㎡)
2
f=fo±5%
△f(3dB)=fo/10
Tamb-Ambient Temperature(℃)
DATE: 2004-08-31
Page: 6
INFRARED REMOTE CONTROL RECEIVER MODULE
PL-IRM0101-3
REV: B / 0
Eemin-Threshold Irradiance(mW/㎡)
S(λ)rel-Relative Spectral Sensitivity
Typical Characteristics(Ta=25℃)
λ-Wavelength(nm)
MAX.Envelope Duty Cycle
Ee-Field Strength of Disturbance(KV/m)
Burst Length (number of cycles/burst)
DRAWING NO.: DS-27-01-0001
drel-Relative transmission Distance
DATE: 2004-08-31
Page: 7
INFRARED REMOTE CONTROL RECEIVER MODULE
PL-IRM0101-3
REV: B / 0
Operation Notes(Standard Condition)
IR CODE
IR Receiver PL-IRM0101-3
Best Application
Suitable
Grundig Code
@
Nec Code
@
Rc5 Code
@
Rc6 Code
@
Rcmm Code
@
Not Recommended
Rcs-80 Code
@
R-2000 Code
@
Rca Code
@
Sharp Code
@
Sony 12bit Code
@
Sony 15bit Code
@
Zenith Code
@
High Data Rate Code
Disturbance Suppression
Note:
@
@
@: Best For Application
Overview Of The Disturbance Suppression Behavior
Disturbance Lamp
IR Receiver PL-IRM0101-3
From Most Used Fluorescent
Lamps
(With Switched Supply)
Best Suppression
From Most Used Fluorescent
Lamps
(With Direct Line Supply)
Best Suppression
From Most Used Fluorescent
Lamps
(With Strong Ballast)
Possibility Of Disturbance Pulses
DRAWING NO.: DS-27-01-0001
DATE: 2004-08-31
Page: 8
INFRARED REMOTE CONTROL RECEIVER MODULE
PL-IRM0101-3
REV: B / 0
Static-Electricity Resistant Packaging
Cautions
1.
2.
3.
4.
5.
Store and use where there is no force causing transformation or change in quality.
Store and use where there is no corrosive gas or sea (salt) breeze.
Store and use where there is no extreme humidity.
Solder the lead-pin within the condition of ratings. After soldering do not add extra force.
Do not wash this device. Wipe the stains of diode side with a soft cloth. You can use the solvent,
ethyl alcohol or methyl alcohol or propylene only.
6. To prevent static electricity damage to the Pre-AMP make sure that the human body, the soldering
iron is connected to ground before using.
7. Put decoupling device between Vcc and GND for reduce the noise from power supply line.
8. The performance of remote-control system depends on environments condition and ability of
peripheral parts. Customer should evaluate the performance as total system in those conditions after
system up with components such as commander and this receiver module.
9. This device is not design to endure radioactive rays and heavily charged particles.
10. In case where any trouble or questions arise, all parties agree to make full discussion covering the
said problem.
DRAWING NO.: DS-27-01-0001
DATE: 2004-08-31
Page: 9
INFRARED REMOTE CONTROL RECEIVER MODULE
PL-IRM0101-3
REV: B / 0
Reliability Test Item And Condition
Test Items
Test Conditions
Failure Judgment Criteria
Samples (n)
Defectives(c)
High Temperature
+85℃ 240hrs
Storage
N=22
C=0
Low Temperature
-25℃ 240hrs
Storage
N=22
C=0
Temperature Cycle
-55℃--------+105℃
(10min)
(10min)
20cycles
High Temperature
85℃ 85%RH 240hrs
High Humidity
Soldering Heat
Performance test
requirement and
criteria given in page 6
should be satisfied.
N=22
C=0
N=22
C=0
N=22
C=0
255±5℃ 10s
Others:
The appearance and specifications of the product may be modified for improvement without notice.
DRAWING NO.: DS-27-01-0001
DATE: 2004-08-31
Page: 10