TI TLV2548MPWREP

TLV2548-EP
www.ti.com
SLAS668 – OCTOBER 2009
3.0-V TO 5.5-V, 12-BIT, 200-KSPS, 4-/8-CHANNEL, LOW-POWER SERIAL
ANALOG-TO-DIGITAL CONVERTER WITH AUTOPOWER-DOWN
Check for Samples: TLV2548-EP
FEATURES
1
•
•
•
•
•
•
•
•
•
•
•
•
Maximum Throughput 200-KSPS
Built-In Reference, Conversion Clock and
8x FIFO
Differential/Integral Nonlinearity Error: ±1.2
LSB
Signal-to-Noise and Distortion Ratio: 70 dB,
fi = 12 kHz
Spurious Free Dynamic Range: 75 dB,
fi = 12 kHz
SPI (CPOL = 0, CPHA = 0)/DSP-Compatible
Serial Interfaces With SCLK up to 20 MHz
Single Wide Range Supply 3.0 Vdc to 5.5 Vdc
Analog Input Range 0 V to Supply Voltage
With 500-kHz BW
Hardware Controlled and Programmable
Sampling Period
Low Operating Current (1.0 mA at 3.3 V,
2.0 mA at 5.5 V With External Ref, 1.7-mA at
3.3V, 2.4-mA at 5.5-V With Internal Ref)
Power Down: Software/Hardware
Power-Down Mode (1 μA Max, Ext Ref),
Autopower-Down Mode (1 μA, Ext Ref)
Programmable Auto-Channel Sweep
SUPPORTS DEFENSE, AEROSPACE,
AND MEDICAL APPLICATIONS
•
•
•
•
•
•
•
Controlled Baseline
One Assembly/Test Site
One Fabrication Site
Available in Military (–55°C/125°C)
Temperature Range (1)
Extended Product Life Cycle
Extended Product-Change Notification
Product Traceability
PW PACKAGE
(TOP VIEW)
SDO
SDI
SCLK
EOC/(INT)
VCC
A0
A1
A2
A3
A4
(1)
1
20
2
19
3
18
4
17
5
16
6
15
7
14
8
13
9
12
10
11
CS
REFP
REFM
FS
PWDN
GND
CSTART
A7
A6
A5
Custom temperature ranges available
DESCRIPTION
The TLV2548 is a high performance, 12-bit low-power, 3.86-μs, CMOS analog-to-digital converter (ADC) which
operates from a single 3.0-V to 5.5-V power supply. This device has three digital inputs and a 3-state output [chip
select (CS), serial input-output clock (SCLK), serial data input (SDI), and serial data output (SDO)] that provide a
direct 4-wire interface to the serial port of most popular host microprocessors (SPI interface). When interfaced
with a TI DSP, a frame sync (FS) signal is used to indicate the start of a serial data frame.
In addition to a high-speed A/D converter and versatile control capability, this device has an on-chip analog
multiplexer that can select any analog inputs or one of three internal self-test voltages. The sample-and-hold
function is automatically started after the fourth SCLK edge (normal sampling) or can be controlled by a special
pin, CSTART, to extend the sampling period (extended sampling). The normal sampling period can also be
programmed as short (12 SCLKs) or as long (24 SCLKs) to accommodate faster SCLK operation popular among
high-performance signal processors. The TLV2548 is designed to operate with very low power consumption. The
power-saving feature is further enhanced with software/hardware/autopower-down modes and programmable
conversion speeds. The conversion clock (OSC) and reference are built-in. The converter can use the external
SCLK as the source of the conversion clock to achieve higher (up to 2.8 μs when a 20-MHz SCLK is used)
conversion speed. Two different internal reference voltages are available. An optional external reference can also
be used to achieve maximum flexibility.
The TLV2548 is characterized for operation from –55°C to 125°C.
1
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas
Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of the Texas
Instruments standard warranty. Production processing does not
necessarily include testing of all parameters.
Copyright © 2009, Texas Instruments Incorporated
TLV2548-EP
SLAS668 – OCTOBER 2009
www.ti.com
FUNCTIONAL BLOCK DIAGRAM
VCC
4/2 V
Reference
REFP
REFM
Analog
MUX
A0
A1
A2
A3
A4
A5
A6
A7
FIFO
12 Bit × 8
S/H
Low Power
12-BIT
SAR ADC
OSC
INT
Command
Decode
EXT
Conversion
Clock
M
U
X
CFR
SDI
SDO
CMR (4 MSBs) DIV
SCLK
CS
FS
CSTART
PWDN
Control Logic
EOC/(INT)
GND
Table 1. ORDERING INFORMATION (1)
TA
PACKAGE
–55°C to 125°C
(1)
(2)
TSSOP-PW
(2)
Tape and Reel of 2000
ORDERABLE PART
NUMBER
TOP-SIDE MARKING
TLV2548MPWREP
TV2548EP
For the most current package and ordering information, see the Package Option Addendum at the end of this document, or see the TI
Web site at www.ti.com.
Package drawings, standard packing quantities, thermal data, symbolization, and PCB design guidelines are available at
www.ti.com/sc/package.
Table 2. TERMINAL FUNCTIONS
TERMINAL
NAME
NO.
A0
A1
A2
A3
A4
A5
A6
A7
6
7
8
9
10
11
12
13
CS
2
I/O
20
DESCRIPTION
I
Analog signal inputs. The analog inputs are applied to these terminals and are internally
multiplexed. The driving source impedance should be less than or equal to 1 kΩ.
xxx
For a source impedance greater than 1 kΩ, use the asynchronous conversion start signal
CSTART (CSTART low time controls the sampling period) or program long sampling period
to increase the sampling time.
I
Chip select. A high-to-low transition on the CS input resets the internal 4-bit counter,
enables SDI, and removes SDO from 3-state within a maximum setup time. SDI is disabled
within a setup time after the 4-bit counter counts to 16 (clock edges) or a low-to-high
transition of CS whichever happens first.
NOTE: CS falling and rising edges need to happen when SCLK is low for a microprocessor
interface such as SPI.
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): TLV2548-EP
TLV2548-EP
www.ti.com
SLAS668 – OCTOBER 2009
Table 2. TERMINAL FUNCTIONS (continued)
TERMINAL
NAME
CSTART
EOC/(INT)
NO.
14
4
I/O
DESCRIPTION
I
This terminal controls the start of sampling of the analog input from a selected multiplex
channel. Sampling time starts with the falling edge of CSTART and ends with the rising edge
of CSTART as long as CS is held high. In mode 01, select cycle, CSTART can be issued as
soon as CHANNEL is selected which means the fifth SCLK during the select cycle, but the
effective sampling time is not started until CS goes to high. The rising edge of CSTART
(when CS = 1) also starts the conversion. Tie this terminal to VCC if not used.
O
End of conversion or interrupt to host processor. [PROGRAMMED AS EOC]: This output
goes from a high-to-low logic level at the end of the sampling period and remains low until
the conversion is complete and data are ready for transfer. EOC is used in conversion mode
00 only.
xxx
[PROGRAMMED AS INT]: This pin can also be programmed as an interrupt output signal to
the host processor. The falling edge of INT indicates data are ready for output. The following
CS↓ or FS clears INT.
FS
17
I
DSP frame sync input. Indication of the start of a serial data frame in or out of the device. If
FS remains low after the falling edge of CS, SDI is not enabled until an active FS is
presented. A high-to-low transition on the FS input resets the internal 4-bit counter and
enables SDI within a maximum setup time. SDI is disabled within a setup time after the 4-bit
counter counts to 16 (clock edges) or a low-to-high transition of CS whichever happens first.
xxx
Tie this terminal to VCC if not used. See the Data Code Information section, item 1.
GND
15
I
Ground return for the internal circuitry. Unless otherwise noted, all voltage measurements
are with respect to GND.
PWDN
16
I
Both analog and reference circuits are powered down when this pin is at logic zero. The
device can be restarted by active CS, FS or CSTART after this pin is pulled back to logic
one.
I
Input serial clock. This terminal receives the serial SCLK from the host processor. SCLK is
used to clock the input SDI to the input register. When programmed, it may also be used as
the source of the conversion clock.
NOTE: This device supports CPOL (clock polarity) = 0, which is SCLK returns to zero when
idling for SPI compatible interface.
I
Serial data input. The input data is presented with the MSB (D15) first. The first 4-bit MSBs,
D(15−12) are decoded as one of the 16 commands. The configure write commands require
an additional 12 bits of data.
xxx
When FS is not used (FS =1), the first MSB (D15) is expected after the falling edge of CS
and is latched in on the rising edges of SCLK (after CS↓).
xxx
When FS is used (typical with an active FS from a DSP) the first MSB (D15) is expected
after the falling edge of FS and is latched in on the falling edges of SCLK.
xxx
SDI is disabled within a setup time after the 4-bit counter counts to 16 (clock edges) or a
low-to-high transition of CS whichever happens first.
SCLK
SDI
3
2
SDO
1
O
The 3-state serial output for the A/D conversion result. SDO is kept in the high-impedance
state when CS is high and after the CS falling edge and until the MSB is presented. The
output format is MSB first.
xxx
When FS is not used (FS = 1 at the falling edge of CS), the MSB is presented to the SDO
pin after the CS falling edge, and successive data are available at the rising edge of SCLK
and changed on the falling edge.
xxx
When FS is used (FS = 0 at the falling edge of CS), the MSB is presented to SDO after the
falling edge of CS and FS = 0 is detected. Successive data are available at the falling edge
of SCLK and changed on the rising edge. (This is typically used with an active FS from a
DSP.)
xxx
For conversion and FIFO read cycles, the first 12 bits are result from previous conversion
(data) followed by 4 don’t care bits. The first four bits from SDO for CFR read cycles should
be ignored. The register content is in the last 12 bits. SDO is 3-state (float) after the 16th bit.
See the Data Code Information section, item 2.
REFM
18
I
External reference input or internal reference decoupling. Tie this pin to analog ground if
internal reference is used.
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): TLV2548-EP
3
TLV2548-EP
SLAS668 – OCTOBER 2009
www.ti.com
Table 2. TERMINAL FUNCTIONS (continued)
TERMINAL
I/O
DESCRIPTION
NAME
NO.
REFP
19
I
External reference input or internal reference decoupling (shunt capacitors of 10 μF and
0.1 μF between REFP and REFM). The maximum input voltage range is determined by the
difference between the voltage applied to this terminal and the REFM terminal when an
external reference is used.
VCC
5
I
Positive supply voltage
Detailed Description
Analog Inputs and Internal Test Voltages
The 4/8 analog inputs and three internal test inputs are selected by the analog multiplexer depending on the
command entered. The input multiplexer is a break-before-make type to reduce input-to-input noise injection
resulting from channel switching.
Converter
The TLV2548 uses a 12-bit successive approximation ADC utilizing a charge redistribution DAC. Figure 1 shows
a simplified version of the ADC.
The sampling capacitor acquires the signal on Ain during the sampling period. When the conversion process
starts, the SAR control logic and charge redistribution DAC are used to add and subtract fixed amounts of charge
from the sampling capacitor to bring the comparator into a balanced condition. When the comparator is balanced,
the conversion is complete and the ADC output code is generated.
Charge
Redistribution
DAC
_
Ain
Control
Logic
+
ADC Code
REFM
Figure 1. Simplified Model of the Successive-Approximation System
Serial Interface
INPUT DATA FORMAT
MSB
LSB
D15−D12
D11−D0
Command ID[15:12]
Configuration data field ID[11:0]
Input data is binary. All trailing blanks can be filled with zeros.
OUTPUT DATA FORMAT READ CFR/FIFO READ
MSB
4
LSB
D15−D12
D11−D0
Don’t care
Register content or FIFO content OD[11:0]
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): TLV2548-EP
TLV2548-EP
www.ti.com
SLAS668 – OCTOBER 2009
OUTPUT DATA FORMAT CONVERSION
MSB
LSB
D15−D4
D3−D0
Conversion result
OD[11:0]
Don’t care
The output data format is binary (unipolar straight binary).
Binary
Zero scale code = 000h, Vcode = VREFM.
Full scale code = FFFh, Vcode = VREFP − 1 LSB
Control and Timing
Power Up and Initialization Requirements
• Determine processor type by writing A000h to the TLV2548 (CS must be toggled).
• Configure the device (CS must make a high-to-low transition, then can be held low if in DSP mode;
i.e., active FS).
The first conversion after power up or resuming from power down is not valid.
Start of the Cycle
• When FS is not used (FS = 1 at the falling edge of CS), the falling edge of CS is the start of the cycle.
• When FS is used (FS is an active signal from a DSP), the falling edge of FS is the start of the cycle.
First 4-MSBs: The Command Register (CMR)
The TLV2548 has a 4-bit command set (see Table 3) plus a 12-bit configuration data field. Most of the
commands require only the first 4 MSBs, i.e., without the 12-bit data field.
The valid commands are listed in Table 3.
Table 3. TLV2548 Command Set (1)
SDI D(15−12) BINARY
(1)
COMMAND
0000b
0h
Select analog input channel 0
0001b
1h
Select analog input channel 1
0010b
2h
Select analog input channel 2
0011b
3h
Select analog input channel 3
0100b
4h
Select analog input channel 4
0101b
5h
Select analog input channel 5
0110b
6h
Select analog input channel 6
0111b
7h
Select analog input channel 7
1000b
8h
SW power down (analog + reference)
1001b
9h
Read CFR register data shown as SDO D(11-0)
1010b
Ah plus data
Write CFR followed by 12–bit data, e.g., 0A100h means external reference,
short sampling, SCLK/4, single shot, INT
1011b
Bh
Select test, voltage = (REFP+REFM)/2
1100b
Ch
Select test, voltage = REFM
1101b
Dh
Select test, voltage = REFP
1110b
Eh
FIFO read, FIFO contents shown as SDO D(15-4), D(3-0) = 0000
1111b
Fh plus data
Reserved
The status of the CFR can be read with a read CFR command when the device is programmed for one–shot conversion mode
(CFR D[6,5] = 00).
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): TLV2548-EP
5
TLV2548-EP
SLAS668 – OCTOBER 2009
www.ti.com
Configuration
Configuration data is stored in one 12–bit configuration register (CFR) (see Table 4 for CFR bit definitions). Once
configured after first power up, the information is retained in the H/W or S/W power down state. When the device
is being configured, a write CFR cycle is issued by the host processor. This is a 16–bit write. If the SCLK stops
after the first eight bits are entered, then the next eight bits can be taken after the SCLK is resumed.
Table 4. TLV2548 Configuration Register (CFR) Bit Definitions
BIT
D11
D10
Internal reference voltage select
0: Internal ref = 4 V
1: internal ref = 2 V
D9
Sample period select
0: Short sampling 12 SCLKs (1x sampling time)
1: Long sampling 24 SCLKs (2x sampling time)
D(8,7)
Conversion clock source select
00: Conversion clock = internal OSC
01: Conversion clock = SCLK
10: Conversion clock = SCLK/4
11: Conversion clock = SCLK/2
D(6,5)
Conversion mode select
00: Single shot mode [FIFO not used, D(1,0) has no effect.]
01: Repeat mode
10: Sweep mode
11: Repeat sweep mode
D(4,3) (1)
Sweep auto sequence select
00: 0-1-2-3-4-5-6-7
01: 0-2-4-6-0-2-4-6
10: 0-0-2-2-4-4-6-6
11: 0-2-0-2-0-2-0-2
D2
EOC/INT - pin function select
0: Pin used as INT
1: Pin used as EOC
D(1,0)
(1)
DEFINITION
Reference select
0: External
1: Internal (Tie REFM to analog ground if the internal reference is selected.)
FIFO trigger level (sweep sequence length)
00: Full (INT generated after FIFO level 7 filled)
01: 3/4 (INT generated after FIFO level 5 filled)
10: 1/2 (INT generated after FIFO level 3 filled)
11: 1/4 (INT generated after FIFO level 1 filled)
These bits only take effect in conversion modes 10 and 11.
Sampling
The sampling period starts after the first four input data are shifted in if they are decoded as one of the
conversion commands. These are select analog input (channels 0 through 7) and select test (channels 1 through
3).
Normal Sampling
When the converter is using normal sampling, the sampling period is programmable. It can be 12 SCLKs (short
sampling) or 24 SCLKs (long sampling). Long sampling helps when SCLK is faster than 10 MHz or when input
source resistance is high.
Extended Sampling
CSTART - An asynchronous (to the SCLK) signal, via dedicated hardware pin, CSTART, can be used in order to
have total control of the sampling period and the start of a conversion. This extended sampling is user defined
and is totally independent of SCLK. While CS is high, the falling edge of CSTART is the start of the sampling
period and is controlled by the low time of CSTART. The minimum low time for CSTART should be at least equal
to the minimum t(SAMPLE). In a select cycle used in mode 01 (REPEAT MODE), CSTART can be started as soon
6
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): TLV2548-EP
TLV2548-EP
www.ti.com
SLAS668 – OCTOBER 2009
as the channel is selected (after the fifth SCLK). In this case the sampling period is not started until CS has
become inactive. Therefore the non-overlapped CSTART low time must meet the minimum sampling time
requirement. The low–to–high transition of CSTART terminates the sampling period and starts the conversion
period. The conversion clock can also be configured to use either internal OSC or external SCLK. This function is
useful for an application that requires:
• The use of an extended sampling period to accommodate different input source impedance.
• The use of a faster I/O clock on the serial port but not enough sampling time is available due to the fixed
number of SCLKs. This could be due to a high input source impedance or due to higher MUX ON resistance
at lower supply voltage.
Once the conversion is complete, the processor can initiate a read cycle by using either the read FIFO command
to read the conversion result or by simply selecting the next channel number for conversion. Since the device
has a valid conversion result in the output buffer, the conversion result is simply presented at the serial data
output. To completely get out of the extended sampling mode, CS must be toggled twice from a high-to-low
transition while CSTART is high. The read cycle mentioned above followed by another configuration cycle of the
ADC qualifies this condition and successfully puts the ADC back to its normal sampling mode. This can be
viewed in Figure 9.
Table 5. Sample and Convert Conditions
CONDITIONS
CSTART
CS = 1
(see Figure 11 and
Figure 19)
CS
CSTART = 1
FS = 1
FS
CSTART = 1
CS = 0
SAMPLE
CONVERT
No sampling clock (SCLK) required.
Sampling period is totally controlled by the low
time of CSTART. The high–to–low transition
of CSTART (when CS = 1) starts the sampling
of the analog input signal. The low time of
CSTART dictates the sampling period. The
low–to–high transition of CSTART ends
sampling period and begins the conversion
cycle. (Note: this trigger only works when
internal reference is selected for conversion
modes 01, 10, and 11.)
1) If the internal clock OSC is selected, a
maximum conversion time of 3.86 μs can be
SCLK is required. Sampling period is
programmable under normal sampling. When achieved.
programmed to sample under short sampling, 2) If external SCLK is selected, conversion
time is tconv = 14 x DIV/f(SCLK), where DIV can
12 SCLKs are generated to complete
be 1, 2, or 4.
sampling period. 24 SCLKs are generated
when programmed for long sampling. A
command set to configure the device requires
4 SCLKs thereby extending to 16 or 28
SCLKs respectively before conversion takes
place. (Note: Because the ADC only bypasses
a valid channel select command, the user can
use select channel 0, 0000b, as the SDI input
when either CS or FS is used as trigger for
conversion. The ADC responds to commands
such as SW powerdown, 1000b.)
TLV2548 Conversion Modes
The TLV2548 has four different conversion modes (mode 00, 01, 10, 11). The operation of each mode is slightly
different, depending on how the converter performs the sampling and which host interface is used. The trigger for
a conversion can be an active CSTART (extended sampling), CS (normal sampling, SPI interface), or FS (normal
sampling, TMS320 DSP interface). When FS is used as the trigger, CS can be held active, i.e. CS does not need
to be toggled through the trigger sequence. SDI can be one of the channel select commands, such as SELECT
CHANNEL 0. Different types of triggers should not be mixed throughout the repeat and sweep operations. When
CSTART is used as the trigger, the conversion starts on the rising edge of CSTART. The minimum low time for
CSTART is equal to t(SAMPLE). If an active CS or FS is used as the trigger, the conversion is started after the 16th
or 28th SCLK edge. Enough time (for conversion) should be allowed between consecutive triggers so that no
conversion is terminated prematurely.
One Shot Mode (Mode 00)
One shot mode (mode 00) does not use the FIFO, and the EOC is generated as the conversion is in progress (or
INT is generated after the conversion is done).
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): TLV2548-EP
7
TLV2548-EP
SLAS668 – OCTOBER 2009
www.ti.com
Repeat Mode (Mode 01)
Repeat mode (mode 01) uses the FIFO. This mode setup requires configuration cycle and channel select cycle.
Once the programmed FIFO threshold is reached, the FIFO must be read, or the data is lost when the sequence
starts over again with the SELECT cycle and series of triggers. No configuration is required except for
re-selecting the channel unless the operation mode is changed. This allows the host to set up the converter and
continue monitoring a fixed input and come back to get a set of samples when preferred.
Triggered by CSTART: The first conversion can be started with a select cycle or CSTART. To do so, the user
can issue CSTART during the select cycle, immediately after the 4-bit channel select command. The first sample
started as soon as the select cycle is finished (i.e., CS returns to 1). If there is enough time (2 μs) left between
the SELECT cycle and the following CSTART, a conversion is carried out. In this case, you need one less trigger
to fill the FIFO. Succeeding samples are triggered by CSTART.
Sweep Mode (Mode 10)
Sweep mode (mode 10) also uses the FIFO. Once it is programmed in this mode, all of the channels listed in the
selected sweep sequence are visited in sequence. The results are converted and stored in the FIFO. This sweep
sequence may not be completed if the FIFO threshold is reached before the list is completed. This allows the
system designer to change the sweep sequence length. Once the FIFO has reached its programmed threshold,
an interrupt (INT) is generated. The host must issue a read FIFO command to read and clear the FIFO before
the next sweep can start.
Repeat Sweep Mode (Mode 11)
Repeat sweep mode (mode 11) works the same way as mode 10 except the operation has an option to continue
even if the FIFO threshold is reached. Once the FIFO has reached its programmed threshold, an interrupt (INT)
is generated. Then two things may happen:
1. The host may choose to act on it (read the FIFO) or ignore it. If the next cycle is a read FIFO cycle, all of the
data stored in the FIFO is retained until it has been read in order.
2. If the next cycle is not a read FIFO cycle, or another CSTART is generated, all of the content stored in the
FIFO is cleared before the next conversion result is stored in the FIFO, and the sweep is continued.
Table 6. TLV2548 Conversion Mode (1)
CONVERSION
MODE
One shot
(1)
(2)
(3)
8
CFR
D(6,5)
SAMPLING
TYPE
(2) (3)
OPERATION
Normal
•
•
•
•
Single conversion from a selected channel
CS or FS to start select/sampling/conversion/read
One INT or EOC generated after each conversion
Host must serve INT by selecting channel, and converting and reading the
previous output.
Extended
•
•
•
•
•
Single conversion from a selected channel
CS to select/read
CSTART to start sampling and conversion
One INT or EOC generated after each conversion
Host must serve INT by selecting next channel and reading the previous
output.
00
Programming the EOC/INT pin as the EOC signal works for mode 00 only. The other three modes automatically generate an INT signal
irrespective of how EOC/INT is programmed.
Extended sampling mode using CSTART as the trigger only works when internal reference is selected for conversion modes 01, 10, and
11.
When using CSTART to sample in extended mode, the falling edge of the next CSTART trigger should occur no more than 2.5 μs after
the falling CS edge (or falling FS edge if FS is active) of the channel select cycle. This is to prevent an ongoing conversion from being
canceled.
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): TLV2548-EP
TLV2548-EP
www.ti.com
SLAS668 – OCTOBER 2009
Table 6. TLV2548 Conversion Mode
CONVERSION
MODE
CFR
D(6,5)
SAMPLING
TYPE
Sweep
•
•
•
•
Repeated conversions from a selected channel
CS or FS to start sampling/conversion
One INT generated after FIFO is filled up to the threshold
Host must serve INT by either 1) (FIFO read) reading out all of the FIFO
contents up to the threshold, then repeat conversions from the same selected
channel or 2) writing another command(s) to change the conversion mode. If
the FIFO is not read when INT is served, it is cleared.
Extended
•
Same as normal sampling except CSTART starts each sampling and
conversion when CS is high.
Normal
•
•
•
•
One conversion per channel from a sequence of channels
CS or FS to start sampling/conversion
One INT generated after FIFO is filled up to the threshold
Host must serve INT by (FIFO read) reading out all of the FIFO contents up to
the threshold, then write another command(s) to change the conversion mode.
Extended
•
Same as normal sampling except CSTART starts each sampling and
conversion when CS is high.
•
•
•
•
Repeated conversions from a sequence of channels
CS or FS to start sampling/conversion
One INT generated after FIFO is filled up to the threshold
Host must serve INT by either 1) (FIFO read) reading out all of the FIFO
contents up to the threshold, then repeat conversions from the same selected
channel or 2) writing another command(s) to change the conversion mode. If
the FIFO is not read when INT is served it is cleared.
•
Same as normal sampling except CSTART starts each sampling and
conversion when CS is high.
01
10
Normal
Repeat sweep
(continued)
OPERATION
Normal
Repeat
(1) (2) (3)
11
Extended
Timing Diagrams
The timing diagrams can be categorized into two major groups: non-conversion and conversion. The
non-conversion cycles are read and write (configuration). None of these cycles carry a conversion. Conversion
cycles are those four modes of conversion.
Read Cycle (Read FIFO or Read CFR)
Read CFR Cycle
The read command is decoded in the first four clocks. SDO outputs the contents of the CFR after the fourth
SCLK. This command works only when the device is programmed in the single shot mode (mode 00).
1
2
3
4
5
6
7
12
13
14
15
1
16
SCLK
CS
FS
SDI
ID15
ID14
ID13
ID12
ID15
INT
EOC
OD11 OD10 OD9
SDO
OD4
OD3
OD2
OD1 OD0
Figure 2. TLV2548 Read CFR Cycle (FS active)
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): TLV2548-EP
9
TLV2548-EP
SLAS668 – OCTOBER 2009
www.ti.com
1
2
3
4
5
7
6
13
12
14
15
1
16
SCLK
CS
FS
SDI
ID15
ID14
ID13
ID12
ID15
ID14
INT
EOC
OD11 OD10
SDO
OD9
OD4
OD3
OD2
OD1
OD0
Figure 3. TLV2548 Read CFR Cycle (FS = 1)
FIFO Read Cycle
The first command in the active cycle after INT is generated, if the FIFO is used, is assumed as the FIFO read
command. The first FIFO content is output immediately before the command is decoded. If this command is not
a FIFO read, then the output is terminated but the first data in the FIFO is retained until a valid FIFO read
command is decoded. Use of more layers of the FIFO reduces the time taken to read multiple data. This is
because the read cycle does not generate EOC or INT, nor does it carry out any conversion.
1
2
3
4
5
6
7
12
13
14
15
16
1
2
ID15
ID14
SCLK
CS
FS
SDI
ID15 ID14
ID13 ID12
INT
EOC
SDO
OD11 OD10
OD9
OD8
OD7 OD6
OD5
OD0
OD11 OD10
These devices can perform continuous FIFO read cycles (FS = 1) controlled by SCLK; SCLK can stop between each 16 SCLKs.
Figure 4. TLV2548 FIFO Read Cycle (FS = 1)
10
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): TLV2548-EP
TLV2548-EP
www.ti.com
SLAS668 – OCTOBER 2009
Write Cycle (Write CFR)
The write cycle is used to write to the configuration register CFR (with 12-bit register content). The write cycle
does not generate an EOC or INT, nor does it carry out any conversion (see power up and initialization
requirements).
1
2
3
4
5
6
7
ID11
ID10
ID9
12
13
14
15
16
1
SCLK
CS
FS
SDI
ID15
ID14
ID13 ID12
ID4
ID3
ID2
ID1
ID0
ID15
INT
EOC
SDO
Figure 5. TLV2548 Write Cycle (FS Active)
1
2
3
4
5
6
7
12
13
14
15
16
ID12
ID11
ID10
ID9
ID4
ID3
ID2
ID1
ID0
1
SCLK
CS
FS
SDI
ID15
ID14 ID13
ID15
ID14
INT
EOC
SDO
Figure 6. TLV2548 Write Cycle (FS = 1)
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): TLV2548-EP
11
TLV2548-EP
SLAS668 – OCTOBER 2009
www.ti.com
Conversion Cycles
DSP/Normal Sampling
1
2
3
4
5
6
7
12
16 Short Sampling
30 Short Sampling
28 Long Sampling
42 Long Sampling
(If CONV
CLK = SCLK0
SCLK
tc (30 or 42 SCLKs)
CS
FS
SDI
ID15
ID14I
ID13 ID12
ID15
INT
t(sample) (12 or 24 SCLKs)
EOC
SDO
(SDOZ on SCLK16L Regardless
of Sampling Time)
MSB-1
MSB
MSB-2
MSB-3
MSB-4
MSB-5
MSB-6
t(conv)
LSB
MSB
Figure 7. Mode 00 Single Shot/Normal Sampling (FS Signal Used)
16 Short Sampling
1
2
3
4
5
6
7
12
13
28 Long Sampling
30 Short Sampling
42 Long Sampling
(If CONV
CLK = SCLK0
1
SCLK
tc (30 or 42 SCLKs)
CS
FS
SDI
ID15
ID14
ID13
ID12
ID15
INT
t(sample) (12 or 24 SCLKs)
EOC
SDO
(SDOZ on SCLK16L Regardless
of Sampling Time)
MSB
MSB-1
MSB-2
MSB-3
MSB-4
MSB-5
MSB-6
t(conv)
LSB
MSB
Figure 8. Mode 00 Single Shot/Normal Sampling (FS = 1, FS Signal Not Used)
12
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): TLV2548-EP
TLV2548-EP
www.ti.com
SLAS668 – OCTOBER 2009
Device Going Into
Extended Sampling Mode
Select/Read
Cycle
Select/Read
Cycle
Read
Cycle
Device Get Out
Extended Sampling
Mode
CS
t(sample )
Normal
Cycle
CSTART
FS
t(conv)
†
†
SDI
INT
EOC
SDO
Previous Conversion
Result
Previous Conversion
Result
Hi-Z
Hi-Z
Hi-Z
† This is one of the single shot commands. Conversion starts on next rising edge of CSTART.
Figure 9. Mode 00 Single Shot/Extended Sampling (FS Signal Used, FS Pin Connected to TMS320 DSP)
Modes Using the FIFO: Modes 01, 10, 11 Timing
Configure Select
Conversion #1
From Channel 2
Conversion #4
From Channel 2
Select
CS
FS
CSTART
SDI
†
§
¶
¶
¶
‡
‡
‡
‡
§
¶
INT
Hi-Z
Hi-Z
SDO
Read FIFO
#1
Top of FIFO
#2
#3
#4
† Command = Configure write for mode 01, FIFO threshold = 1/2
‡ Command = Read FIFO, first FIFO read
§ Command = Select ch2.
¶ Use any channel select command to trigger SDI input.
Figure 10. TLV2548 Mode 01 DSP Serial Interface (Conversions Triggered by FS)
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): TLV2548-EP
13
TLV2548-EP
SLAS668 – OCTOBER 2009
www.ti.com
Conversion #1 From Channel 2
Configure Select
CS
Conversion #4 From Channel 2
Select
¶
FS
(DSP)
t(sample)
t(sample)
t(sample)
t(sample)
CSTART
SDI
†
§
‡
‡
‡
‡
§
INT
Hi-Z
SDO
Hi-Z
Read FIFO
#1
#2
First FIFO Read
Sample Times ≥ MIN t(sample)
(See Operating Characteristics)
#3
#4
† Command = Configure write for mode 01, FIFO threshold = 1/2
‡ Command = Read FIFO, first FIFO read
§ Command = Select ch2.
¶ Minimum CS low time for select cycle is 6 SCLKs. The same amount of time is required between FS low to CSTART for proper channel decoding.
The low time of CSTART, not overlapped with CS low time, is the valid sampling time for the select cycle (see Figure 19).
Figure 11. TLV2548 Mode 01 μp/DSP Serial Interface (Conversions Triggered by CSTART)
Conversion
From Channel 0
Configure
Conversion
From Channel 3
Conversion
From Channel 0
Conversion
From Channel 3
CS
FS
(DSP)
CSTART
SDI
†
§
§
§
§
‡
‡
‡
‡
§
§
§
§
‡
Read FIFO
#1
INT
SDO
Repeat
Read FIFO
#1
#2
#3
Top of FIFO
First FIFO Read
#4
Repeat
Second FIFO Read
† Command = Configure write for mode 10 or 11, FIFO threshold = 1/2, sweep seq = 0-1-2-3.
‡ Command = Read FIFO
§ Use any channel select command to trigger SDI input.
Figure 12. TLV2548 Mode 10/11 DSP Serial Interface (Conversions Triggered by FS)
14
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): TLV2548-EP
TLV2548-EP
www.ti.com
SLAS668 – OCTOBER 2009
Conversion
From Channel 0
Conversion
From Channel 3
Conversion
From Channel 3
Conversion
From Channel 0
Configure
CS
FS
(DSP)
CSTART
t(sample)
t(sample)
t(sample)
t(sample)
SDI
‡
†
‡
‡
‡
#3
#4
‡
INT
SDO
Read FIFO
Repeat
#1
#2
Top of FIFO
Read FIFO
Repeat
#1
Second FIFO Read
First FIFO Read
† Command = Configure write for mode 10 or 11, FIFO threshold = 1/2, sweep seq = 0-1-2-3.
‡ Command = Read FIFO
Figure 13. TLV2548 Mode 10/11 DSP Serial Interface (Conversions Triggered by CSTART)
Conversion
From Channel 0
Conversion
From Channel 0
Conversion
From Channel 3
Conversion
From Channel 3
Configure
CS
CSTART
SDI
†
§
§
§
§
‡
‡
‡
‡
§
§
§
§
‡
INT
SDO
Read FIFO
Repeat
#1
#2
#3
Top of FIFO
First FIFO Read
#4
Read FIFO
#1
Repeat
Second FIFO Read
† Command = Configure write for mode 10 or 11, FIFO threshold = 1/2, sweep seq = 0-1-2-3.
‡ Command = Read FIFO
§ Use any channel select command to trigger SDI input.
Figure 14. TLV2548 Mode 10/11 μp Serial Interface (Conversions Triggered by CS)
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): TLV2548-EP
15
TLV2548-EP
SLAS668 – OCTOBER 2009
www.ti.com
FIFO Operation
Serial
SDO
12-BITx8
FIFO
ADC
7
6
FIFO Full
5
4
3
2
1
0
FIFO 1/2 Full
FIFO 3/4 Full
FIFO 1/4 Full
FIFO Threshold Pointer
Figure 15. TLV2548 FIFO
The device has an eight-layer FIFO that can be programmed for different thresholds. An interrupt is sent to the
host after the pre-programmed threshold is reached. The FIFO can be used to store data from either a fixed
channel or a series of channels based on a pre-programmed sweep sequence. For example, an application may
require eight measurements from channel 3. In this case, the FIFO is filled with eight data sequentially taken
from channel 3. Another application may require data from channel 0, channel 2, channel 4, and channel 6 in an
orderly manner. Therefore, the threshold is set for 1/2 and the sweep sequence 0−2−4−6−0−2−4−6 is chosen.
An interrupt is sent to the host as soon as all four data are in the FIFO.
In single shot mode, the FIFO automatically uses a 1/8 FIFO depth. Therefore the CFR bits (D1,0) controlling
FIFO depth are don’t care.
SCLK and Conversion Speed
There are two ways to adjust the conversion speed.
• The SCLK can be used as the source of the conversion clock to get the highest throughput of the device.
The minimum onboard OSC is 3.6 MHz and 14 conversion clocks are required to complete a conversion
(corresponding 3.86-μs conversion time). The devices can operate with an SCLK up to 20 MHz for the supply
voltage range specified. When a more accurate conversion time is desired, the SCLK can be used as the
source of the conversion clock. The clock divider provides speed options appropriate for an application where
a high speed SCLK is used for faster I/O. The total conversion time is 14 x (DIV/fSCLK) where DIV is 1, 2, or 4.
For example a 20-MHz SCLK with the divide by 4 option produces a 14 x (4/20 M) = 2.8-μs conversion time.
When an external serial clock (SCLK) is used as the source of the conversion clock, the maximum equivalent
conversion clock (fSCLK/DIV) should not exceed 6 MHz.
• Autopower down can be used to slow down the device at a reduced power consumption level. This mode is
always used by the converter. If the device is not accessed (by CS or CSTART), the converter is powered
down to save power. The built-in reference is left on in order to quickly resume operation within one half
SCLK period. This provides unlimited choices to trade speed with power savings.
Reference Voltage
The device has a built-in reference with a programmable level of 2 V or 4 V. If the internal reference is used,
REFP is set to 2 V or 4 V and REFM should be connected to the analog ground of the converter. An external
reference can also be used through two reference input pins, REFP and REFM, if the reference source is
programmed as external. The voltage levels applied to these pins establish the upper and lower limits of the
analog inputs to produce a full-scale and zero-scale reading respectively. The values of REFP, REFM, and the
analog input should not exceed the positive supply or be lower than GND consistent with the specified absolute
maximum ratings. The digital output is at full scale when the input signal is equal to or higher than REFP and at
zero when the input signal is equal to or lower than REFM.
16
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): TLV2548-EP
TLV2548-EP
www.ti.com
SLAS668 – OCTOBER 2009
Reference Block Equivalent Circuit
INTERNAL
REF
Close = Int Ref Used
Open = Ext Ref Used
REFP
Sample
0.1- mF
Decoupling
Cap
Convert
10-mF
Internal
Reference
Compensation
Cap
~50 pF
CDAC
REFM (See Note 1)
External to the Device
A.
If internal reference is used, tie REFM to analog ground and install a 10-μF (or 4.7-μF) internal reference
compensation capacitor between REFP and REFM to store the charge as shown in the figure above.
B.
If external reference is used, the 10-μF (internal reference compensation) capacitor is optional. REFM can be
connected to external REFM or AGND.
C.
Internal reference voltage drift, due to temperature variations, is approximately ±10 mV about the nominal 2 V
(typically) from –10°C to 100°C. The nominal value also varies approximately ±50 mV across devices.
D.
Internal reference leakage during low ON time: Leakage resistance is on the order of 100 MΩ or more. This means
the time constant is about 1000 s with 10-μF compensation capacitance. Since the REF voltage does not vary much,
the reference comes up quickly after resuming from auto power down. At power up and power down the internal
reference sees a glitch of about 500 μV when 2-V internal reference is used (1 mV when 4-V internal reference is
used). This glitch settles out after about 50 μs.
Figure 16. Reference Block Equivalent Circuit
Power Down
The device has three power-down modes.
Autopower-Down Mode
The device enters the autopower-down state at the end of a conversion.
In autopower-down, the power consumption reduces to about 1 mA when an internal reference is selected. The
built-in reference is still on to allow the device to resume quickly. The resumption is fast enough (within
0.5 SCLK) for use between cycles. An active CS, FS, or CSTART resumes the device from power-down state.
The power current is 1 μA when an external reference is programmed and SCLK stops.
Hardware/Software Power-Down Mode
Writing 8000h to the device puts the device into a software power-down state, and the entire chip (including the
built-in reference) is powered down. For a hardware power down, the dedicated PWDN pin provides another way
to power down the device asynchronously. These two power-down modes power down the entire device
including the built-in reference to save power. The power-down current is reduced to about 1 μA as the SCLK is
stopped.
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): TLV2548-EP
17
TLV2548-EP
SLAS668 – OCTOBER 2009
www.ti.com
An active CS, FS, or CSTART restores the device. There is no time delay when an external reference is
selected. However, if an internal reference is used, it takes about 20 ms to warm up. Deselect PWDN pin to
remove the device from the hardware power-down state. This requires about 20 ms to warm up if an internal
reference is also selected.
The configuration register is not affected by any of the power-down modes but the sweep operation sequence
has to be started over again. All FIFO contents are cleared by the power-down modes.
ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range (unless otherwise noted)
(1)
Supply voltage range, GND to VCC
Analog input voltage range
UNIT
–0.3 to 6.5
V
–0.3 to VCC + 0.3
V
VCC + 0.3
V
Reference input voltage
Digital input voltage range
VALUE
–0.3 to VCC + 0.3
V
TJ
Operating virtual junction temperature range
–55 to 150
°C
TA
Operating free-air temperature range
–55 to 125
°C
Tstg
Storage temperature range
–65 to 150
°C
260
°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds
(1)
Stresses beyond those listed under the absolute maximum ratings may cause permanent damage to the device. These are stress
ratings only, and functional operation of the device at these or any other conditions beyond those indicated under the recommended
operating conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
DISSIPATION RATINGS
(1)
PACKAGE
TA < 25°C
POWER RATING
DERATING FACTOR
ABOVE TA = 25°C (1)
TA = 125°C
POWER RATING
20 PW
977 mW
7.8 mW/°C
195 mW
This is the inverse of the traditional junction-to-ambient thermal resistance (RθJA). Thermal resistance is not production tested and the
values given are for informational purposes only.
RECOMMENDED OPERATING CONDITIONS
over operating free-air temperature range (unless otherwise noted)
VCC
MIN
NOM
Supply voltage
3
3.3
Analog input voltage (1)
0
MAX
UNIT
5.5
V
VCC
V
VIH
High level control input voltage
VIL
Low–level control input voltage
td(CSL–FSH)
Delay time, delay from CS falling edge to FS rising edge
(see Figure 17).
0.5
SCLKs
td(SCLK–CSH)
Delay time, delay from 16th SCLK falling edge to CS
rising edge (FS = 1), or 17th rising edge (FS is active)
(see Figure 17 and Figure 20).
0.5
SCLKs
tsu(FSH–SCLKL
Setup time, FS rising edge before SCLK falling edge
(see Figure 17).
20
ns
th(FSH–SCLKL)
Hold time, FS hold high after SCLK falling edge
(see Figure 17).
30
ns
twH(CS)
Pulse width, CS high time (see Figure 17 and Figure 20).
100
ns
twH(FS)
Pulse width, FS high time (see Figure 17).
tc(SCLK)
SCLK cycle time
(see Figure 17 and
Figure 20).
(1)
18
2.1
V
0.6
0.75
1
VCC = 3.0 V to 3.6 V
67
10000
VCC = 4.5 V to 5.5V
50
10000
V
SCLKs
ns
When binary output format is used, analog input voltages greater than that applied to REFP convert as all ones (111111111111), while
input voltages less than that applied to REFM convert as all zeros (000000000000). The device is functional with reference down to 1 V.
(VREFP − VREFM − 1); however, the electrical specifications are no longer applicable.
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): TLV2548-EP
TLV2548-EP
www.ti.com
SLAS668 – OCTOBER 2009
RECOMMENDED OPERATING CONDITIONS (continued)
over operating free-air temperature range (unless otherwise noted)
MIN
NOM
MAX
UNIT
VCC = 4.5 V
22
twL(SCLK)
Pulse width, SCLK low
time (see Figure 17 and
Figure 20)
VCC = 3.0 V
27
Pulse width, SCLK high
time (see Figure 17 and
Figure 20)
VCC = 4.5 V
22
twH(SCLK)
VCC = 3.0 V
27
tsu(DI–SCLK
Setup time, SDI valid before falling edge of SCLK (FS is
active) or the rising edge of SCLK (FS=1)
(see and Figure 20).
25
ns
th(DI–SCLK)
Hold time, SDI hold valid after falling edge of SCLK (FS
is active) or the rising edge of SCLK (FS=1)
(see Figure 17).
5
ns
td(CSL–DOV)
Delay time, delay from CS falling edge to SDO valid
(see Figure 17 and Figure 20).
25
ns
td(FSL–DOV)
Delay time, delay from FS falling edge to SDO valid
(see Figure 17).
25
ns
td(SCLK–DOV)
Delay time, delay from
SCLK falling edge (FS is VCC = 5.5 V
active) or SCLK rising
edge (FS=1) to SDO valid
(see Figure 17 and
Figure 20).
For a date code later than VCC = 3.0 V
xxx, see the Data Code
Information section, item
3.
SDO = 0 pF
ns
ns
0.5 SCLK + 5
SDO = 60 pF
0.5 SCLK + 24
SDO = 5 pF
0.5 SCLK + 12
ns
SDO = 25 pF
td(SCLK–EOCL)
Delay time, delay from 17th SCLK rising edge (FS is
active) or the 16th falling edge (FS=1) to EOC falling
edge
(see Figure 17 and Figure 20).
td(SCLK–INTL)
Delay time, delay from 16th SCLK falling edge to INT
falling edge (FS =1) or from the 17th rising edge SCLK
to INT falling edge (when FS active) (see Figure 20).
td(CSL–INTH)
or
td(FSH–INTH)
Delay time, delay from CS falling edge or FS rising edge
to INT rising edge (see Figure 17, Figure 18, Figure 19
and Figure 20).
td(CSH–CSTARTL)
Delay time, delay from CS rising edge to CSTART falling
edge (see Figure 18 and Figure 19).
td(CSTARTH–EOCL)
Delay time, delay from CSTART rising edge to EOC
falling edge (see Figure 18 and Figure 19).
twL(CSTART)
Pulse width, CSTART low time (see Figure 18 and
Figure 19).
td(CSTARTH–CSTARTL)
Delay time, delay from CSTART rising edge to CSTART
falling edge (see Figure 19).
td(CSTARTH–INTL)
Delay time, delay from CSTART rising edge to INT
falling edge (see Figure 18 and Figure 19).
TA
Operating free–air temperature
0.5 SCLK + 33
45
ns
Min t(conv)
µs
50
100
ns
ns
50
ns
Min t(sample)
μs
Max t(conv)
μs
μs
Max t(conv)
–55
125
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): TLV2548-EP
°C
19
TLV2548-EP
SLAS668 – OCTOBER 2009
www.ti.com
ELECTRICAL CHARACTERISTICS
over operating free-air temperature range, VCC = VREFP = 3 V to 5.5 V, VREFM = 0 V, SCLK frequency = 20 MHz at 5 V,
15 MHz at 3 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
VCC = 5.5 V, IOH = -0.2 mA at 30 pF load
MIN
TYP
(1)
MAX
2.4
UNIT
VOH
High–level output voltage
VOL
Low–level output voltage
IOZ
Off–state output current
(high–impedance–state)
VO = VCC
CS = VCC
VO = 0
CS = VCC
IIH
High–level input current
VI = VCC
0.005
2.5
μA
IIL
Low–level input current
VI = 0 V
–0.005
2.5
μA
VCC = 3.0 V, IOH = –20 μA at 30 pF load
V
VCC-0.2
VCC = 5.5 V, IOL = 0.8 mA at 30 pF load
0.4
VCC = 3.0 V, IOL = 20 μA at 30 pF load
0.1
CS at 0 V, Ext ref
Operating supply current,
normal short sampling
CS at 0 V, Int ref
ICC
CS at 0 V, Ext ref
Operating supply current,
extended sampling
CS at 0 V, Int ref
2.5
–2.5
VCC = 4.5 V to 5.5 V
VCC = 3.0 V to 3.3 V
1
VCC = 4.5 V to 5.5 V
2.4
VCC = 3.0 V to 3.3 V
1.7
VCC = 4.5 V to 5.5 V
1.1
VCC = 3.0 V to 3.3 V
1
VCC = 4.5 V to 5.5 V
2.1
VCC = 3.0 V to 3.3 V
1.6
Power down supply current
for all digital inputs,
0 ≤ VI ≤ 0.3 V or
VI ≥ VCC - 0.3 V, SCLK = 0
VCC = 4.5 V to 5.5 V, Ext clock
1
VCC = 2.7 V to 3.3 V, Ext clock
1
VCC = 4.5 V to 5.5 V, Ext clock, Ext ref
1.0 (2)
ICC(AUTOPWDN)
Auto power–down current
for all digital inputs,
0 ≤ VI ≤ 0.3 V or
VI ≥ VCC - 0.3 V, SCLK = 0
VCC = 2.7 V to 3.3 V, Ext ref, Ext clock
1.0 (3)
Selected channel leakage
current
Selected channel at VCC
2.5
Selected channel at 0 V
2.5
Ci
Input capacitance
Zi
Input MUX ON resistance
μA
2
ICC(PD)
Maximum static analog
reference current into
REFP (use external
reference)
V
VREFP = VCC = 5.5 V, VREFM = GND
mA
μA
μA
μA
μA
1
Analog inputs
45
50
Control Inputs
5
25
VCC = 4.5 V
500
VCC = 2.7 V
600
pF
Ω
AC SPECIFICATIONS
SINAD
Signal-to-noise ratio +
distortion
fI = 12 kHz at 200 KSPS
THD
Total harmonic distortion
fI = 12 kHz at 200 KSPS
ENOB
Effective number of bits
fI = 12 kHz at 200 KSPS
11.6
SFDR
Spurious free dynamic range fI = 12 kHz at 200 KSPS
–84
65
71
dB
TA = –55°C
–82
–73
All other
temperatures
–82
–75
dB
Bits
–75
dB
Analog Input
(1)
(2)
(3)
20
Full-power bandwidth, –3 dB
1
MHz
Full-power bandwidth, –1 dB
500
kHz
All typical values are at VCC = 5 V, TA = 25°C.
1.2 mA if internal reference is used, 165 μA if internal clock is used.
0.8 mA if internal reference is used, 116 μA if internal clock is used.
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): TLV2548-EP
TLV2548-EP
www.ti.com
SLAS668 – OCTOBER 2009
ELECTRICAL CHARACTERISTICS (continued)
over operating free-air temperature range, VCC = VREFP = 3 V to 5.5 V, VREFM = 0 V, SCLK frequency = 20 MHz at 5 V,
15 MHz at 3 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
(1)
MAX
UNIT
(4)
REFERENCE SPECIFICATIONS
(0.1 μF and 10 μF between REFP and
REFM pins)
REFP
Positive reference input
voltage
VCC = 2.7 V to 5.5 V
2
VCC
V
REFM
Negative reference input
voltage
VCC = 2.7 V to 5.5 V
0
2
V
VCC = 5.5 V
Reference Input impedance
Reference Input voltage
difference
REFP-REFM
Internal reference voltage
(4)
(5)
100
SCLK = 20 MHz
CS = 0,
(on)
20
CS = 1, SCLK = 0 (off)
VCC = 2.7 V
REFP-REFM
CS = 1, SCLK = 0, (off)
SCLK = 15 MHz
CS = 0,
(on)
VCC = 2.7 V to 5.5 V
MΩ
25
kΩ
100
20
MΩ
25
2
kΩ
VCC
VCC = 5.5 V
VREF SELECT = 4 V
3.85
4
4.15
VCC = 5.5 V
VREF SELECT = 2 V
1.925
2
2.075
VCC = 2.7 V
VREF SELECT = 2 V
1.925
2
2.075
Internal reference start–up
time
VCC = 5.5 V, 2.7 V with 10 μF compensation cap
20
Internal reference
temperature coefficient
VCC = 2.7 V to 5.5 V
16
V
V
ms
40 (5)
PPM/°C
Specified by design.
Specified by design.
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): TLV2548-EP
21
TLV2548-EP
SLAS668 – OCTOBER 2009
www.ti.com
OPERATING CHARACTERISTICS
over operating free-air temperature range, VCC = VREFP = 3 V to 5.5 V, VREFM = 0 V, SCLK frequency = 20 MHz at 5 V,
15 MHz at 3 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
EL
Integral linearity error (INL)
ED
Differential linearity error (DNL)
EO
Offset error
EFS
(4)
Full scale error
(4)
Self–test output code
MIN
See
(3)
See
(3)
Conversion time
t(sample)
Sampling time
(1)
(2)
(3)
(4)
(5)
22
(1)
See
(5)
(3)
MAX UNIT
±1.2
LSB
±1.2
LSB
TA = 25°C and
125°C
–4
6
TA = –55°C
–4
6.2
TA = 25°C and
125°C
–4
6
TA = –55°C
–4
7.6
SDI = B000h
800h
(2048D)
SDI = C000h
000h (0D)
SDI = D000h
FFFh
(4095D)
Internal OSC
t(conv)
TYP
(2)
3.2
(14 x DIV) /
fSCLK
External SCLK
With a maximum of 1-kW input source
impedance
600
LSB
LSB
4.5
μs
ns
All typical values are at TA = 25°C.
Linear error is the maximum deviation from the best straight line through the A/D transfer characteristics.
Analog input voltages greater than that applied to REFP convert as all ones (111111111111), while input voltages less than that applied
to REFM convert as all zeros (000000000000).
Zero error is the difference between 000000000000 and the converted output for zero input voltage: full-scale error is the difference
between 111111111111 and the converted output for full-scale input voltage.
Both the input data and the output codes are expressed in positive logic.
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): TLV2548-EP
TLV2548-EP
www.ti.com
SLAS668 – OCTOBER 2009
PARAMETER MEASUREMENT INFORMATION
VIH
CS
VIL
twH(CS)
tWH(FS)
td(CSL-FSH)
VIH
FS
VIL
th(FSH-SCLKL)
td(CSL-INTH)
twH(SCLK)
td(SCLK-CSH)
tc(SCLK)
tsu(FSH-SCLKL)
1
td(FSH-INTH)
2
15
16
SCLK
twL(SCLK)
tsu(DI-SCLK)
th(DI-SCLK)
td(CSL-DOV)
SDI
ID15
ID14
VIH
ID1
ID0
VIL
td(FSL-DOV)
Hi-Z
SDO
td(FSL-DOV)
OD11
OD10
don’t care
Hi-Z
don’t care
VOH
OD15
VOL
td(SCLK-EOCL)
td(SCLK-DOV)
t(conv)
VOH
EOC
VOL
td(SCLK-INTL)
VOH
INT
VOL
Figure 17. Critical Timing, DSP Mode (Normal Sampling, FS is Active)
SELECT CYCLE
VIH
CS
VIL
td(CSH-CSTARTL)
twL(CSTART)
VIH
CSTART
†
VIL
td(CSTARTH-INTL)
t(CONV)
VOH
EOC
VOL
td(CSTARTH-EOCL)
td(CSL-INTH)
INT
VOH
VOL
† CSTART falling edge may come before the rising edge of CS but no sooner than the fifth SCLK of the SELECT CYCLE.
Figure 18. Critical Timing (Extended Sampling, Single Shot)
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): TLV2548-EP
23
TLV2548-EP
SLAS668 – OCTOBER 2009
www.ti.com
PARAMETER MEASUREMENT INFORMATION (continued)
SELECT CYCLE
VIH
CS
twL(CSTART)
VIL
td(CSTARTHCSTARTL)
td(CSH-CSTARTL)
VIH
CSTART
VIL
†
VOH
EOC
td(CSL-INTH)
td(CSTARTH-EOCL)
VOL
td(CSTARTH-INTL)
VOH
INT
VOL
† CSTART falling edge may come before the rising edge of CS but no sooner than the fifth SCLK of the SELECT CYCLE. In this case, the actual
sampling time is measured from the rising edge CS to the rising edge of CSTART.
Figure 19. Critical Timing (Extended Sampling, Repeat/Sweep/Repeat Sweep)
VIH
CS
twH(CS)
twH(SCLK)
VIL
td(SCLK-CSH)
tc(SCLK)
1
2
15
16
VIH
SCLK
VIL
twL(SCLK)
tsu(DI-SCLK)
th(DI-SCLK)
SDI
ID15
ID14
VIH
ID1
ID0
VIL
td(CSL-DOV)
SDO
Hi-Z
OD11
OD10
don’t care
VOH
Hi-Z
don’t care
VOL
td(SCLK-DOV)
td(SCLK-EOCL)
t(conv)
VOH
EOC
VOL
td(SCLK-INTL)
td(CSL-INTH)
VOH
INT
VOL
Figure 20. Critical Timing, Microprocessor Mode (Normal Sampling, FS = 1)
24
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): TLV2548-EP
TLV2548-EP
www.ti.com
SLAS668 – OCTOBER 2009
TYPICAL CHARACTERISTICS
INTEGRAL NONLINEARITY
vs
TEMPERATURE
INTEGRAL NONLINEARITY
vs
TEMPERATURE
0.6
0.53
0.595
INL - Integral Nonlinearity - LSB
INL - Integral Nonlinearity - LSB
0.52
0.51
0.5
0.49
0.48
VCC = 2.7 V, Internal Reference = 2 V,
Internal Oscillator, Single Shot,
Short Sample, Mode 00 mP Mode
0.59
0.585
0.58
0.575
0.57
0.565
0.47
25 41.25 57.5 73.75 90
-40 -23.75 -7.5 8.75
TA - Temperature - °C
VCC = 5.5 V, Internal Reference = 2 V,
Internal Oscillator, Single Shot,
Short Sample, Mode 00 mP Mode
0.56
25 41.25 57.5 73.75
-40 -23.75 -7.5 8.75
TA - Temperature - °C
Figure 21.
Figure 22.
DIFFERENTIAL NONLINEARITY
vs
TEMPERATURE
DIFFERENTIAL NONLINEARITY
vs
TEMPERATURE
0.496
90
0.48
DNL - Differential Nonlinearity - LSB
DNL - Differential Nonlinearity - LSB
0.494
0.492
0.49
0.488
0.486
0.484
0.482
VCC = 2.7 V, Internal Reference = 2 V,
Internal Oscillator, Single Shot,
Short Sample, Mode 00 mP Mode
0.47
0.46
0.45
0.44
0.43
VCC = 5.5 V, Internal Reference = 2 V,
Internal Oscillator, Single Shot,
Short Sample, Mode 00 mP Mode
0.48
0.478
25 41.25 57.5 73.75
-40 -23.75 -7.5 8.75
TA - Temperature - °C
90
0.42
25 41.25 57.5 73.75
-40 -23.75 -7.5 8.75
TA - Temperature - °C
Figure 23.
90
Figure 24.
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): TLV2548-EP
25
TLV2548-EP
SLAS668 – OCTOBER 2009
www.ti.com
TYPICAL CHARACTERISTICS (continued)
GAIN ERROR
vs
TEMPERATURE
1.2
0.5
1
0
0.8
-0.5
Gain Error - LSB
Offset Error - LSB
OFFSET ERROR
vs
TEMPERATURE
0.6
0.4
0.2
VCC = 5 V, Internal Reference = 4 V,
External Oscillator = SCLK/4,
Single Shot, Long Sample,
Mode 00 mP Mode
0
25 41.25 57.5 73.75
-40 -23.75 -7.5 8.75
TA - Temperature - °C
VCC = 5 V, Internal Reference = 4 V,
External Oscillator = SCLK/4,
Single Shot, Long Sample,
Mode 00 mP Mode
-2.5
-40 -23.75 -7.5 8.75 25 41.25 57.5 73.75
TA - Temperature - °C
90
Figure 25.
Figure 26.
SUPPLY CURRENT
vs
TEMPERATURE
POWER DOWN CURRENT
vs
TEMPERATURE
External Reference = 4 V, Internal Oscillator,
Single Shot, Short Sample, Mode 00 mP Mode
0.2
VCC = 5 V
Powerdown Current - mA
1.2
Short Sample
0.8
VCC = 5 V, External Reference = 4 V,
Internal Oscillator, Single Shot,
Short Sample, Mode 00 mP Mode
0.6
-40 -23.75 -7.5
0
0.2
0.4
VCC = 2.7 V
0.6
VCC = 5.5 V
0.8
1
25 41.25 57.5 73.75
8.75
TA - Temperature - °C
90
25 41.25 57.5 73.75
-40 -23.75 -7.5 8.75
TA - Temperature - °C
Figure 27.
26
90
0.4
Long Sample
Supply Current - mA
-1.5
-2
1.4
1
-1
90
Figure 28.
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): TLV2548-EP
TLV2548-EP
www.ti.com
SLAS668 – OCTOBER 2009
TYPICAL CHARACTERISTICS (continued)
INL - Integral Nonlinearity - LSB
INTEGRAL NONLINEARITY
vs
SAMPLES
1.0
VCC = 2.7 V, Internal Reference = 2 V, Internal Oscillator,
Single Shot, Short Sample, Mode 00 mP Mode
0.5
0.0
-0.5
-1.0
0
Samples
4097
Figure 29.
DNL - Differential Nonlinearity - LSB
DIFFERENTIAL NONLINEARITY
vs
SAMPLES
1.0
VCC = 2.7 V, Internal Reference = 2 V, Internal Oscillator,
Single Shot, Short Sample, Mode 00 mP Mode
0.5
0.0
-0.5
-1.0
0
Samples
4097
Figure 30.
INL - Integral Nonlinearity - LSB
INTEGRAL NONLINEARITY
vs
SAMPLES
1.0
VCC = 5 V, Internal Reference = 2 V, Internal Oscillator,
Single Shot, Short Sample, Mode 00 mP Mode
0.5
0.0
-0.5
-1.0
0
Samples
4097
Figure 31.
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): TLV2548-EP
27
TLV2548-EP
SLAS668 – OCTOBER 2009
www.ti.com
TYPICAL CHARACTERISTICS (continued)
DNL - Differential Nonlinearity - LSB
DIFFERENTIAL NONLINEARITY
vs
SAMPLES
1.0
VCC = 5 V, Internal Reference = 2 V, Internal Oscillator,
Single Shot, Short Sample, Mode 00 mP Mode
0.5
0.0
-0.5
-1.0
0
4097
Samples
Figure 32.
Magnitude - dB
MAGNITUDE
vs
FREQUENCY
100%
160
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
VCC = 5 V, External Reference = 4 V,
Internal Oscillator , Single Shot, Long Sample, Mode 00 mP
Mode @ 200 KSPS
0
5
10
15
20
25 30
35 40
45
50
55
60
65
70
75
80 85
90
95 100
f - Frequency - kHz
Figure 33.
28
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): TLV2548-EP
TLV2548-EP
www.ti.com
SLAS668 – OCTOBER 2009
TYPICAL CHARACTERISTICS (continued)
SIGNAL-TO-NOISE + DISTORTION
vs
INPUT FREQUENCY
EFFECTIVE NUMBER OF BITS
vs
INPUT FREQUENCY
ENOB - Effective Number of Bits - BITS
-67.50
-68
-68.50
-69
-69.50
VCC = 5 V,
External Reference = 4 V,
Internal Oscillator,
Single Shot, Long Sample,
Mode 00 mP Mode
-70
-70.50
-71
THD - Total Harmonic Distortion - dB
11.50
0
50
100
f - Frequency - kHz
11.40
11.30
11.20
11.10
10.90
0
Figure 35.
TOTAL HARMONIC DISTORTION
vs
INPUT FREQUENCY
SPURIOUS FREE DYNAMIC RANGE
vs
INPUT FREQUENCY
-73
-70
-74
-71
-72
-73
-74
-75
VCC = 5 V,
External Reference = 4 V,
Internal Oscillator,
Single Shot, Long Sample,
Mode 00 mP Mode
-77
-78
-79
0
50
100
f - Frequency - kHz
Figure 34.
-69
-76
VCC = 5 V,
External Reference = 4 V,
Internal Oscillator,
Single Shot, Long Sample,
Mode 00 mP Mode
11
10.80
150
Spurious Free Dynamic Range - dB
SINAD - Signal-to-Noise + Distortion - dB
-67
50
100
f - Frequency - kHz
-75
-76
-77
-78
-79
VCC = 5 V,
External Reference = 4 V,
Internal Oscillator,
Single Shot, Long Sample,
Mode 00 mP Mode
-80
-81
150
150
-82
0
Figure 36.
50
100
f - Frequency - kHz
150
Figure 37.
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): TLV2548-EP
29
TLV2548-EP
SLAS668 – OCTOBER 2009
www.ti.com
TYPICAL CHARACTERISTICS (continued)
SIGNAL-TO-NOISE RATIO
vs
INPUT FREQUENCY
SNR - Signal-to-Noise Ratio - dB
-70.2
VCC = 5 V,
External Reference = 4 V,
Internal Oscillator,
Single Shot, Long Sample,
Mode 00 mP Mode
-70.4
-70.6
-70.8
-71
-71.2
-71.4
0
50
100
f - Frequency - kHz
Figure 38.
150
PRINCIPLES OF OPERATION
vcc
10 kΩ
VDD
XF
CS
TXD
SDI
RXD
SDO
AIN
CLKR
CLKX
TMS320 DSP
BIO
FSR
FSX
SCLK
INT
TLV2548
FS
GND
Figure 39. Typical Interface to a TMS320 DSP
DATA CODE INFORMATION
Parts with a date code earlier than 31xxxxx have the following discrepancies:
1. Earlier devices react to FS input irrespective of the state of the CS signal.
2. The earlier silicon was designed with SDO prereleased half clock ahead. This means in the microcontroller
mode (FS=1) the SDO is changed on the rising edge of SCLK with a delay; and for DSP serial port (when FS
is active) the SDO is changed on the falling edge of SCLK with a delay. This helps the setup time for
processor input data, but may reduce the hold time for processor input data. It is recommended that a
100-pF capacitance be added to the SDO line of the ADC when interfacing with a slower processor that
30
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): TLV2548-EP
TLV2548-EP
www.ti.com
SLAS668 – OCTOBER 2009
requires longer input data hold time.
3. For earlier silicon, the delay time is specified as:
MIN
Delay time, delay from SCLK falling edge (FS is
active) or SDO = 100 pF 20 ns SCLK rising edge
(FS = 1) to next SDO valid, td(SCLK-DOV).
VCC = 4.5 V
VCC = 2.7 V
SDO = 0 pF
16
SDO = 100 pF
20
SDO = 0 pF
24
SDO = 100 pF
30
NOM
MAX
UNIT
ns
This is because the SDO is changed at the rising edge in the up mode with a delay. This is the hold time
required by the external digital host processor, therefore, a minimum value is specified. The newer silicon
has been revised with SDO changed at the falling edge in the up mode with a delay. Since at least 0.5 SCLK
exists as the hold time for the external host processor, the specified maximum value helps with the
calculation of the setup time requirement of the external digital host processor.
For an explanation of the DSP mode, reverse the rising/falling edges in item 2. above.
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): TLV2548-EP
31
PACKAGE OPTION ADDENDUM
www.ti.com
19-Mar-2011
PACKAGING INFORMATION
Orderable Device
Status
(1)
Package Type Package
Drawing
Pins
Package Qty
Eco Plan
(2)
Lead/
Ball Finish
MSL Peak Temp
TLV2548MPWREP
ACTIVE
TSSOP
PW
20
2000
Green (RoHS
& no Sb/Br)
CU NIPDAU Level-1-260C-UNLIM
V62/10603-01XE
ACTIVE
TSSOP
PW
20
2000
Green (RoHS
& no Sb/Br)
CU NIPDAU Level-1-260C-UNLIM
(3)
Samples
(Requires Login)
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2)
Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability
information and additional product content details.
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that
lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between
the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight
in homogeneous material)
(3)
MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature.
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information
provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and
continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals.
TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.
OTHER QUALIFIED VERSIONS OF TLV2548-EP :
• Catalog: TLV2548
• Military: TLV2548M
Addendum-Page 1
PACKAGE OPTION ADDENDUM
www.ti.com
19-Mar-2011
NOTE: Qualified Version Definitions:
• Catalog - TI's standard catalog product
• Military - QML certified for Military and Defense Applications
Addendum-Page 2
PACKAGE MATERIALS INFORMATION
www.ti.com
14-Jul-2012
TAPE AND REEL INFORMATION
*All dimensions are nominal
Device
TLV2548MPWREP
Package Package Pins
Type Drawing
TSSOP
PW
20
SPQ
Reel
Reel
A0
Diameter Width (mm)
(mm) W1 (mm)
2000
330.0
16.4
Pack Materials-Page 1
6.95
B0
(mm)
K0
(mm)
P1
(mm)
7.1
1.6
8.0
W
Pin1
(mm) Quadrant
16.0
Q1
PACKAGE MATERIALS INFORMATION
www.ti.com
14-Jul-2012
*All dimensions are nominal
Device
Package Type
Package Drawing
Pins
SPQ
Length (mm)
Width (mm)
Height (mm)
TLV2548MPWREP
TSSOP
PW
20
2000
367.0
367.0
38.0
Pack Materials-Page 2
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other
changes to its semiconductor products and services per JESD46C and to discontinue any product or service per JESD48B. Buyers should
obtain the latest relevant information before placing orders and should verify that such information is current and complete. All
semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale supplied at the time
of order acknowledgment.
TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms
and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary
to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily
performed.
TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and
applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or
other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information
published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or
endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the
third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration
and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered
documentation. Information of third parties may be subject to additional restrictions.
Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service
voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice.
TI is not responsible or liable for any such statements.
Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements
concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support
that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which
anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause
harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use
of any TI components in safety-critical applications.
In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to
help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and
requirements. Nonetheless, such components are subject to these terms.
No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties
have executed a special agreement specifically governing such use.
Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in
military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components
which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and
regulatory requirements in connection with such use.
TI has specifically designated certain components which meet ISO/TS16949 requirements, mainly for automotive use. Components which
have not been so designated are neither designed nor intended for automotive use; and TI will not be responsible for any failure of such
components to meet such requirements.
Products
Applications
Audio
www.ti.com/audio
Automotive and Transportation www.ti.com/automotive
Amplifiers
amplifier.ti.com
Communications and Telecom www.ti.com/communications
Data Converters
dataconverter.ti.com
Computers and Peripherals
www.ti.com/computers
DLP® Products
www.dlp.com
Consumer Electronics
www.ti.com/consumer-apps
DSP
dsp.ti.com
Energy and Lighting
www.ti.com/energy
Clocks and Timers
www.ti.com/clocks
Industrial
www.ti.com/industrial
Interface
interface.ti.com
Medical
www.ti.com/medical
Logic
logic.ti.com
Security
www.ti.com/security
Power Mgmt
power.ti.com
Space, Avionics and Defense
www.ti.com/space-avionics-defense
Microcontrollers
microcontroller.ti.com
Video and Imaging
www.ti.com/video
RFID
www.ti-rfid.com
OMAP Mobile Processors
www.ti.com/omap
TI E2E Community
e2e.ti.com
Wireless Connectivity
www.ti.com/wirelessconnectivity
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2012, Texas Instruments Incorporated