ETC CR-V3

R
Primary Lithium Battery Expert
Primary lithium batteries
CR-V3 3.0V 2.9Ah
3 .0V Primary lithium-mamganese dioxide
(Li-MnO 2 ) Power type
CR-V3 -size spiral cell
For high drain/high pulses
applications requesting superior
voltage response in -40 ~+60
environments.
Cell size references
CR-V3
Alternative models
CR-V3
Electrical characteristics
(typical values relative to cells stored for one year or less at +30 max.)
Nominal capacity
(at 1mA +20 2.0V cut off. The capacity restored by the cell varies
according to current drain, temperature and cut off).
2.9Ah
Open circuit voltage (at +20 )
3.0V
Nominal voltage
3.0V
(at 1mA +20 )
Pulse capability: Typically up to 3000 mA (3000 mA/0.1 second pul
ses,
drained every 2 mn at +20 from undischarged cells with 10 A base
current, yield voltage readings above 3.0V. The readings may vary according
to the pulse characteristics, the temperature, and the cell s previous history.
Fitting the cell with a capacito r may be recommended in severe conditions.
Consult ABLE)
Max. Continuous current
Max. Pulse current
Storage
(recommended)
(for more severe conditions, consult ABLE)
Operating temperature range
(Operation above ambient T may lead to reduced capacity and
lower voltage readings at the beginning of pulses. Consult ABLE)
2000mA
3000mA
+30
+86 F max
-40
/ +60
Physical characteristics
Diameter (max)
Width (max)
Height (max)
Typical weight
Available termination suffix
28.6mm(1.1 in)
19.5mm(0.39 in)
52.2mm(2 in)
39g(1.3oz)
-
Tel:0086 755 29807561/63 Fax:0086 755 29807510 Email:[email protected] Web page: www.able-battery.com
R
Primary Lithium Battery Expert
CR-V3
3.0V 2.9Ah
Key features
High and stable operating voltage
Superior drain capability
Low self-discharge rate
(less than 3% after 1year of storage
at +20 )
Optional stainless steel container for
low magnetic and nickle plated steel
container for more safe design
Hermetic glass-to-metal sealing
Notch technology for safety vent is
recommended
PTC for finished product is optional
Main applications
Radiocommunication and other
military applications
Alarms and security systems
Beacons and emergency location
transmitters
GPS
Metering systems
Sonobuoys
LED lighting applications
Others
Characteristic curves
Discharge performance
25
Voltage
V
4.0
Storage
The storage area should be clean,
cool (not exceeding +30 ), dry
and ventilated.
3.0
2.0
1.0
0.1
500mA 50mA
2.2Ah 2.6Ah
1
10
15mA
2.7Ah
10
2
1mA
2.9Ah
10
3
10
Hours
Nominal capacity 2.9Ah 1mA to 2.0V .
4
10
5
Warning
Do not use if the battery casing was
mangled.
Don t use different models of battery
in series.
Soldering the tag should be finished
in few seconds .
Do not try to recharge.
Tel:0086 755 29807561/63 Fax:0086 755 29807510 Email:[email protected] Web page: www.able-battery.com