ETC ER13150

R
Primary Lithium Battery Expert
Primary lithium batteries
ER13150 3.6V 450mAh
3.6V Primary lithium-thionyl chloride
(Li-SOCl 2 ) Energy type
bobbin cell
For low drain / long tetm operating
applications requesting superior
voltage response in -55 ~+85
environments.
Cell size references
Alternative models
Electrical characteristics
(typical values relative to cells stored for one year or less at +30 max.)
Nominal capacity
(at 0.5 mA +20 2.0V cut off. The capacity restored by the cell varies
according to current drain, temperature and cut off).
0.45Ah
Open circuit voltage (at +20 )
Nominal voltage
3.66V
(at 0.5mA +20 )
3.6V
Pulse capability: Typically up to 20 mA (30 mA/0.1 second pulses,
drained every 2 mn at +20 from undischarged cells with 10 A base
current, yield voltage readings above 3.0V. The readings may vary according
to the pulse characteristics, the temperature, and the cell s previous history.
Fitting the cell with a capacitor may be recommended in severe conditions.
Consult ABLE)
Max. Continuous current
Max. Pulse current
Storage
10mA
20mA
(recommended)
(for more severe conditions, consult ABLE)
Operating temperature range
(Operation above ambient T may lead to reduced capacity and
lower voltage readings at the beginning of pulses. Consult ABLE)
+30
+86 F max
-55 / +85
-76 F / +185 F
Physical characteristics
Diameter (max)
13mm(0.45 in)
Height (max)
15mm(0.6 in)
Typical weight
5.5g(0.18oz)
Available termination suffix
radial tabs, radial pins, axial leads, flying leads
Tel:0086 755 29807561/63 Fax:0086 755 29807510 Email:[email protected] website:www.able-battery.com
R
Primary Lithium Battery Expert
Characteristic curves
O
Discharge performance
3.6V 450mAh
C
3.5
V
ER13150
25
3.0
4.0
1
0.05
5
0.1
(+)
Voltage
3.5
3.0
2.5
2.5
2.0
0 1 2 3 4 5 6 7 8 9 10
***S*
2.0
10mA 4mA
0.5mA 100 A
0.28Ah 0.35Ah 0.45Ah 0.39 Ah
1.5
1.0
0.1
15.0Max
1
10
2
3
10
4
10
Hours
10
5
10
13.0Max
Capacity VS Current
0.5
20 C
Storage
The storage area should be clean,
cool (not exceeding +30 ), dry
and ventilated.
Warning
Do not use if the battery casing was
mangled.
Please discharge the battery few
minutes with 100mA,if the battery
voltage is lower than your need or consult ABLE.
Don t use different models of battery
in series.
Soldering the tag should be finished
in few seconds.
Do not try to recharge.
O
Capacity
72 C
0.3
O
55 C
0.2
O
-30 C
O
0C
0.1
0.0
0.01
0.1
Current
1
10
mA
100
Voltage VS Temperature
3.8
3.6
10 A
V
Main applications
Radiocommunication and other
military applications
Alarms and security systems
Beacons and emergency location
transmitters
GPS
Metering systems
Sonobuoys
LED lighting applications
Others
0.4
3.4
0.1mA
Voltage
Key features
High and stable operating voltage
Superior drain capability
Low self-discharge rate
(less than 1% after 1year of storage
at +20 )
Optional stainless steel container for
low magnetic and nickle plated steel
container for more safe design
Hermetic glass-to-metal sealing
Notch technology for safety vent is
recommended
Non-flammable electrolyte
Ah
O
3.2
0.5mA
3.0
2.8
-60
2mA
-40 -20
0
20
Temperature
40
60
80
Tel:0086 755 29807561/63 Fax:0086 755 29807510 Email:[email protected] website:www.able-battery.com