ETC QEB125

• SINGLE OUTPUT UP TO 35A
• INDUSTRY STANDARD FOOTPRINT
• NO MINIMUM LOAD
• ADJUSTABLE OUTPUT VOLTAGE
• UNDER-VOLTAGE LOCKOUT
• HIGH EFFICIENCY UP TO 90%
• COMPACT 2.28 X 1.45 X 0.50 INCH PACKAGE
• FIXED SWITCHING FREQUENCY
QEB125 single output DC/DC converters provide up to 125 watts of output power in
an industry standard quarter-brick package and footprint. These units are specifically
designed to meet the power needs of low-voltage silicon. All models feature a wide
input range, trimmable output voltage and a 35A current rating. Remote sense and
remote on/off facilities are included as standard, and the converters are
comprehensively protected against over-current, over-voltage and over-temperature
conditions. The QEB125 converters are especially suited to telecom, networking and
industrial application.
UL E193009
TUV R50020744
CB JPTUV-5363
CE MARK
T E C H N I C A L S P E C I F I C AT I O N
All specifications are typical at nominal input, full load and 25ºC otherwise noted
OUTPUT SPECIFICATIONS
GENERAL SPECIFICATIONS
Output power
125 Watts max
Voltage accuracy
Full load and nominal Vin
Voltage adjustability
(Note1)
± 1.5%
None
Line regulation
LL to HL at FL
Load regulation
No load to Full load
±0.2%
See table
Remote Sense
10% of Vout
20MHz bandwidth (Measured
with a 1uF M/C and a 10uF T/C)
100mVp-p
0.02% / ºC, max
Temperature coefficient
Transient response recovery time
See table
Input to Output
Input to Case
Output to Case
Isolation voltage
+ 10% , -20%
Minimum load
Ripple and noise
Efficiency
25% load step change
Over voltage protection
threshold(Non-latching Hiccup)
200uS
120% Vout max
7
Isolation resistance
10 ohms, min
Isolation capacitance
2500 pF, max
Switching frequency
270 KHz, typ
Approvals and standard
IEC60950, UL60950, EN60950
Case material
Aluminum base plate
Weight (approx)
MTBF
42g (1.46 oz)
Bellcore TR-NWT-000332, Tc=40 ºC , Io=80%,max
110% ~ 140% of lout Rated
Short circuit protection
Hiccup, automatics recovery
INPUT SPECIFICATIONS
Over temperature protection
48V nominal input
Under voltage lockout
Power up
Power down
36 – 75VDC
34V typ.
32V typ.
Vibration
110ºC, max
MIL-STD-810D
10~55Hz, 2G, 3minutes period, 30minutes along X,Y and Z
Humidity , Max , Non-Condensing
Input filter (Note 2)
L-C type
EMC CHARACTERISTICS
Input surge voltage 100mS max
100VDC
Conducted emissions
Nominal Vin and
constant resistor load
Power up
Remote ON/OFF
Remote ON/OFF (Note3)
(Negative logic)
(Positive logic)
DC-DC
DC-DC
DC-DC
DC-DC
ON
OFF
ON
OFF
25mS typ
25mS typ
ION/OFF = 1mA max
Short or 0V < Vr < 1.2V
Open or 3.5V < Vr < 15V
Open or 3.5V < Vr < 15V
Short or 0V < Vr < 1.2V
-40ºC to +100ºC
-55ºC to +125ºC
Storage temperature range
Thermal shock
Input voltage range
2.5 x 106 hrs
ENVIRONMENTAL SPECIFICATIONS
Operating base-plate temperature range (Note 4)
Over Current Protection threshold
Start up time
1600VDC,min
1000VDC,min
1000VDC,min
Radiated emissions
EN55022 (Note 5)
EN55022 (Note 5)
EN55022
ESD
Radiated immunity
Fast transient
Surge
Conducted immunity
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
95%
Level A
Level B
Level A
Perf. Criteria2
Perf. Criteria2
Perf. Criteria2
Perf. Criteria2
Perf. Criteria2
Input
Range
Model
Number
Output
Voltage
Output
Current
(6)
Eff
(%)
Load
regulation
QEB125-48S1P8
36 – 75 VDC
1.8 VDC
35A
84
5.4mV
QEB125-48S2P5
36 – 75 VDC
2.5 VDC
35A
86
7.5mV
QEB125-48S3P3
36 – 75 VDC
3.3 VDC
30A
88
10mV
QEB125-48S05
36 – 75 VDC
5 VDC
25A
90
15mV
Note
1.
2.
3.
4.
5.
6.
7.
8.
Maximum output deviation is 10% inclusive of trim. If remote sense is not being used, the +V sense should be connected to its corresponding
+OUTPUT and likewise the –sense should be connected to its corresponding –OUTPUT.
An external filter capacitor is required for normal operation. The capacitor should be capable of handing 1A ripple current for 48V models. Power mate
suggest: Nippon chemi-con KMF series, 220F/100V, ESR 90m.
The negative / positive logic and pin length are optional ( see table ). The pin voltage is referenced to negative input.
Heat sink is optional and P/N7G-00297G-00307G-00317G-0032.
The QEB125 meets level A and level B conducted emissions only with external components connected before the input pin to the converter.
Typical value at nominal input voltage and full load
BASEPLATE GROUNGINGBase-plate should be grounded at one of the four screw bolts prior to operation.
The converter is provided by basic insulation.
(7)
EXTERNAL OUTPUT TRIMMING
Output can be externally trimmed by
using the method shown below.
TRIM UP
TRIM DOWN
7
6
RU
6
RD
5
PIN CONNECTION
PIN
Define
1
2
3
4
5
6
7
8
- INPUT
ON/OFF
+ INPUT
- OUTPUT
- SENSE
TRIM
+ SENSE
+ OUTPUT
PRODUCT OPTIONS TABLE
Option
Suffix
Negative remote ON/OFF logic, 0.20” pin length (standard)
-
Negative remote ON/OFF logic, 0.145” pin length
-L
Negative remote ON/OFF logic, 0.11” pin length
-K
Positive remote ON/OFF logic, 0.20” pin length
-P
Positive remote ON/OFF logic, 0.145” pin length
-S
Positive remote ON/OFF logic, 0.11” pin length
-M
Example