HEC50 SERIES 50 WATTS DC-DC CONVERTER FEATURES • 50 WATTS MAXIMUM OUTPUT POWER • SINGLE OUTPUT UP TO 15A • COMPACT 2.40 X 2.28 X 0.50 INCH PACKAGE • HIGH EFFICIENCY UP TO 91% • INPUT RANGE FROM 18VDC TO 36VDC AND 36VDC TO 75VDC • FIXED SWITCHING FREQUENCY(300kHz) • HALT TESTED • INDUSTRY STANDARD FOOTPRINT • ADJUSTABLE OUTPUT VOLTAGE • NO MINIMUM LOAD REQUIRED • UNDER-VOLTAGE LOCKOUT • INPUT TO OUTPUT BASIC INSULATION:1600 VDC • CE MARK MEETS 2006/95/EC, 2011/95/EC AND 2004/108/EC • SAFETY MEETS UL60950-1, EN60950-1 AND IEC60950-1 • ISO9001 CERTIFIED MANUFACTURING FACILITIES • COMPLIANT TO RoHS EU DIRECTIVE 2011/65/EU OPTIONS Positive logic remote on/off, pin length APPLICATIONS Wireless Network Telecom/Datacom Industry Control System Distributed Power Architectures Semiconductor Equipment DESCRIPTION HEC50 single output DC/DC converters provide up to 50 watts of output power in an industry standard half-brick package and footprint. These units are specifically designed to meet the power needs of low-voltage silicon. All models feature a wide input range, trimmable output voltage and a 15A current rating. T E C H N I C A L S P E C I F I C AT I O N All specifications are typical at nominal input, full load and 25ºC otherwise noted OUTPUT SPECIFICATIONS Output power Voltage accuracy 24VDC nominal input 48VDC nominal input 0% Input filter Voltage adjustability (Note 5) LL to HL at Full Load No load to Full load Remote sense (Note 5) + 10% , -20% See table See table 10% of Vout(nom) Ripple and noise (Note 6) 20MHz bandwidth 100mVp-p ±0.02% / ºC, max. Temperature coefficient Transient response recovery time 25% load step change 200µs Over voltage protection threshold (Hiccup) 115% ~ 130% of Vout(nom) Over current protection threshold 110% ~ 140% of Iout Rated Short circuit protection Continuous, automatics recovery GENERAL SPECIFICATIONS Efficiency Isolation voltage Input voltage range ± 1.5% Minimum load Line regulation Load regulation INPUT SPECIFICATIONS 50 Watts, max. Input to Output Input(Output) to Case 500VDC See table 1600 VDC, min. 1minute 1000 VDC, min. 1minute 7 Isolation resistance 10 ohms, min. Isolation capacitance 2500pF, max. Switching frequency 300kHz±10% Design meets safety standard IEC60950-1, UL60950-1, EN60950-1 Case material Open with Aluminum base-plate Weight 50g (1.76oz) BELLCORE TR-NWT-000332 1.037 x 106 hrs MTBF (Note 1) MIL-HDBK-217F 2.560 x 105 hrs 18 ~ 36VDC 36 ~ 75VDC L-C type 24VDC input 50VDC 100ms, max. Input surge voltage 48VDC input 100VDC 100ms, max. Nominal input and Power up 25ms Start up time constant resistive load Remote ON/OFF 25ms Input reflected ripple current 24VDC input 50mAp-p 48VDCinput 20mAp-p 24VDC input 17VDC Start-up voltage 48VDC input 34VDC 24VDC input 15VDC Shutdown voltage 48VDC input 32VDC Remote ON/OFF (Note 7) (Negative logic) ON=Short or 0V < Vr < 1.2V, IIN=1mA max. OFF=Open or 3V < Vr < 15V, IIN=50µA max. ON=Open or 3V < Vr < 15V, IIN=50µA max. (Positive logic) OFF=Short or 0V < Vr < 1.2V, IIN=1mA max. Input current of remote control pin Nominal input -0.5mA ~ 0.5mA Remote off state input current Nominal input 20mA ENVIRONMENTAL SPECIFICATIONS Operating base-plate temperature range (Note 8) Over temperature protection Humidity max, Non-condensing Storage temperature range Thermal shock Vibration -40ºC ~ +100ºC 110ºC 95% -55ºC ~ +125ºC MIL-STD-810F MIL-STD-810F EMC CHARACTERISTICS EMI (Note 9) Radiated immunity Fast transient (Note 10) Surge (Note 10) Conducted immunity Page 1 of 3 www.pduke.com EN55022 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 Class A, Class B Perf. Criteria A Perf. Criteria B Perf. Criteria B 10 Vr.m.s Perf. Criteria A 10 V/m ± 2kV ± 1kV 2013/5/3 HEC50 SERIES 50 WATTS Output Current Model Number Input Range Output Voltage Min. load HEC50-24S1P8 18 ~ 36 VDC 1.8 VDC 0mA HEC50-24S2P5 18 ~ 36 VDC 2.5 VDC 0mA 15 A HEC50-24S3P3 18 ~ 36 VDC 3.3 VDC 0mA 15 A HEC50-24S05 18 ~ 36 VDC 5 VDC 0mA 10 A DC-DC CONVERTER (3) (4) Full load Line regulation Load regulation No load Input Current 15 A 4 mV 6 mV 120mA 86 5 mV 8 mV 100mA 87 7 mV 10 mV 120mA 89 10 mV 15 mV 120mA 90 Eff (%) HEC50-24S15 18 ~ 36 VDC 15 VDC 0mA 3.3 A 30 mV 45 mV 190mA 89 HEC50-48S1P8 36 ~ 75 VDC 1.8 VDC 0mA 15 A 4 mV 6 mV 80mA 87 HEC50-48S2P5 36 ~ 75 VDC 2.5 VDC 0mA 15 A 5 mV 8 mV 80mA 88 HEC50-48S3P3 36 ~ 75 VDC 3.3 VDC 0mA 15 A 7 mV 10 mV 110mA 90 HEC50-48S05 36 ~ 75 VDC 5 VDC 0mA 10 A 10 mV 15 mV 90mA 91 HEC50-48S15 36 ~ 75 VDC 15 VDC 0mA 3.3 A 30 mV 45 mV 130mA 90 Note 1. BELLCORE TR-NWT-000332. Case 1: 50% Stress, Temperature at 40ºC. MIL-HDBK-217F Notice2 @Ta=25 ºC, Full load (Ground, Benign, controlled environment). 2. The converter is provided by basic insulation. 3. Typical value at nominal input voltage and no load. 4. Typical value at nominal input voltage and full load. 5. Maximum output deviation is 10% inclusive of remote sense. If remote sense is not being used, the + SENSE should be connected to its corresponding +OUTPUT and likewise the –SENSE should be connected to its corresponding –OUTPUT. 6. Measured with a 1µF M/C and a 10µF T/C. 7. The negative/ positive logic and pin length are optional (see table). The pin voltage is referenced to –INPUT 8. Heat-sink is optional and P/N: 7G-0021A-F, 7G-0022A-F, 7G-0023A-F, 7G-0024A-F. 9. The HEC50 series standard module meets EN55022 Class A and Class B with external components. For more detail information, please contact with P-DUKE. 10. An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5. The filter capacitor Power Mate suggest: Nippon chemi-con KY series, 220µF/100V. 11. CASE GROUNDING:When connect the case pin and four screw bolts to shield plane, the EMI could be reduced. CAUTION: This power module is not internally fused. An input line fuse must always be used. Page 2 of 3 www.pduke.com 2013/5/3 HEC50 SERIES 50 WATTS MECHANICAL DRAWING DC-DC CONVERTER : 1. All dimensions in Inch (mm) Tolerance: X.XX±0.02 (X.X±0.5) X.XXX±0.01 (X.XX±0.25) 2. Pin pitch tolerance ±0.01(0.25) 3. Pin dimension tolerance ±0.004 (0.1) PIN CONNECTION PIN 1 2 3 4 5 6 7 8 9 DEFINE -INPUT CASE CTRL +INPUT -OUTPUT -SENSE TRIM +SENSE +OUTPUT EXTERNAL OUTPUT TRIMMING DIAMETER 0.040 Inch(1.02mm) 0.040 Inch(1.02mm) 0.040 Inch(1.02mm) 0.040 Inch(1.02mm) 0.080 Inch(2.03mm) 0.040 Inch(1.02mm) 0.040 Inch(1.02mm) 0.040 Inch(1.02mm) 0.080 Inch(2.03mm) Remote On/Off and Pin Options Negative remote ON/OFF logic, 0.200” pin length (standard) Negative remote ON/OFF logic, 0.145” pin length Positive remote ON/OFF logic, 0.200” pin length Positive remote ON/OFF logic, 0.145” pin length Output can be externally trimmed by using the method shown below. TRIM UP TRIM DOWN 7 6 RU 8 Suffix -L -P -S RD 7 Heat-Sink and Mounting Hole Tread Options Without heat-sink 7G-0021A-F 7G-0022A-F 7G-0023A-F 7G-0024A-F Through hole (No thread) Suffix -HS -HS1 -HS2 -HS3 -TH Example:HEC50-48S3P3-PHS * The module can’t equip heat-sink with TH option. Page 3 of 3 www.pduke.com 2013/5/3