JMK. Inc. HH-1355E-3 The HH-1355E-3 filter has been designed to operate with the VICOR Harmonic Attenuator Module (HAM). This filter was specifically designed to allow the Vicor HAM and Associated power converters to meet Mil-Std-461D & E. The enclosure mounting, and pin configuration are identical to the enclosure for the standard HAM filter. It will be necessary to add transient protection across the output of the filter to protect the HAM module. It is recommended that you use 5%, bipolar TVS diodes. 2 x 130V and 1 x 150V diodes connected in series. The HAM will meet Mil-Std-461D or E with the HH-1355-3. The one draw back is that the current is limited to 3 amps max. Order Part Number: HH-1355E-3 Operating voltage________________85 to 250 V~ Operating current ________________3.0 Amp Max Operating frequency______________50/400 Hz Operating temperature____________-20—55C *** Diel. withstanding (line - case)____1500 Vac Diel. withstanding (line - line)_____1500 Vdc Leakage current__________________2.5 ma @ 220 V, 60 Hz Max residual voltage after 1 sec__ 34 Volts Applicable Specifications________Mil-Std-461E *** Wider operating temperature ranges available. USA JMK Inc 15 Caldwell Dr. Amherst, NH 03031 EUR JMK Inc Glasgow G13 1DN Scotland UK PH: 603 886-4100 FX: 603 886-4115 email: [email protected] PH: 44-(0) 7785310729 FX: 44-(0) 141-589-1884