JMK KK-1306-30

JMK, Inc
1306 SERIES
LOAD
LINE
Operating voltage = 115/250 Vac
Operating current = 20, 30 Amp
Operating frequency = 50/60Hz
Operating temperature = -20o to 50o C
Transient suppression = 354—432 volts
Maximum transient energy = 40 joules
Leakage current = 3.5 ma at 250 Vac, 60 Hz
Max residual voltage after 1 sec. = 30 Volts
INSERTION LOSS 1306 SERIES
90
80
INSERTION LOSS (db)
70
CM-20
60
CM-30
DM
50
40
30
20
10
0
.01
.04
.02
.1
.07
.4
.2
1
.7
4
2
10
7
40
20
100
70
FREQUENCY (MEGAHERTZ)
The 1306 filter is the same as
the 1151 series with the addition of transient suppression
devices. It is very useful in
power control systems operating in very noisy environments. The filter is also useful
in any systems using switched
mode power supplies.
For the system with a space
problem this filter has the
maximum insertion loss provided in a very small package.
M4 X 0.7 - 6H
(2 PL)
0.38
M4 X 0.7 - 6H
(4 PL)
1.60
10-32 TH'D
TERM (6 PL)
0.80
2.310
3.06
0.80
0.53
2.000
0.53
0.63
1.660
2.70 MAX.
0.75
3.06
Ordering Information
20 AMPS - KK-1306-20
30 AMPS - KK-1306-30
USA
JMK Inc 15 Caldwell Dr. Amherst, NH 03031
EUR
JMK Inc Glasgow G13 1DN Scotland UK
PH: 603 886-4100
FX: 603 886-4115
email: [email protected]