MEANWELL MPS-30-15

MPS-30
30W Single Output for Medical Type
series
Features :
Universal AC input / Full range
Low leakage current
0.3mA
Protections: Short circuit / Overload / Over voltage / Over temperature
Fixed switching frequency at 100KHz
Low cost
High reliability
3 years warranty
EN60601-1
IEC60601-1
SPECIFICATION
MODEL
OUTPUT
INPUT
MPS-30-5
MPS-30-12
MPS-30-15
MPS-30-24
MPS-30-27
DC VOLTAGE
5V
12V
15V
24V
27V
48V
RATED CURRENT
5A
2.5A
2A
1.2A
1.1A
0.6A
CURRENT RANGE
0 ~ 5A
0 ~ 2.5A
0 ~ 2A
0 ~ 1.2A
0 ~ 1.1A
0 ~ 0.6A
RATED POWER
25W
30W
30W
28.8W
29.7W
28.8W
120mVp-p
150mVp-p
240mVp-p
240mVp-p
240mVp-p
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE TOLERANCE Note.3
3.0%
3.0%
3.0%
3.0%
3.0%
2.0%
LINE REGULATION
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
2.0%
1.0%
1.0%
1.0%
1.0%
1.0%
SETUP, RISE TIME
500ms, 30ms/230VAC
HOLD UP TIME (Typ.)
70ms/230VAC
VOLTAGE RANGE
88 ~ 264VAC auto switch
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
72%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
0.8A/115VAC
SAFETY STANDARDS
WITHSTAND VOLTAGE
76%
77%
13.2 ~ 16.2V
5.5 ~ 6.75V
78%
78%
16.5 ~ 20.25V
26.4 ~ 32.4V
29.7 ~ 36.45V
52.8 ~ 64.8V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Tj 135 typically (U1) detect on main control IC
Protection type : Shut down o/p voltage, re-power on to recover
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.03%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL2601-1, TUV EN60601-1, IEC60601-1 approved
I/P-O/P:4KVAC
I/P-FG:1.5KVAC
O/P-FG:SHORT
ISOLATION RESISTANCE
I/P-O/P, I/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION Compliance to EN55011 (CISPR11) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2, medical level, criteria A
DIMENSION
PACKING
NOTE
75%
0.5A/230VAC
Above 105% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
OTHERS
120 ~ 370VDC
OVERLOAD
WORKING TEMP.
WORKING HUMIDITY
(Note 4)
12ms/115VAC at full load
COLD START 30A/230VAC
<0.3mA / 264VAC
OVER TEMPERATURE
EMC
500ms, 30ms/115VAC at full load
LEAKAGE CURRENT
PROTECTION OVER VOLTAGE
SAFETY &
MPS-30-48
547Khrs min. MIL-HDBK-217F (25
101.6*65.8*23.5mm (L*W*H)
0.16Kg; 90pcs/15.8Kg/1.02CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:MPS-30-SPEC 2008-03-25
MPS-30
30W Single Output for Medical Type
Mechanical Specification
series
Unit:mm
101.6
66.1
95.2
18
3.2
3.2
51.4
62.6
65.8
CN2
CN1
4
3
2
1
M3
L=
6m
5
4
3
2
1
m
FUSE*2
T2.5A 250V
3.2
2 max.
23.5 max.
4-
AC Input Connector (CN1) : Molex 41791-5 or equivalent
Pin No.
1
2,4
3
5
Assignment
FG
No Pin
AC/N
AC/L
Mating Housing
Terminal
Molex 2139
or equivalent
Molex 2478
or equivalent
DC Output Connector (CN2) : Molex 41791-4 or equivalent
Pin No.
1,2
3,4
Assignment
-V
+V
Mating Housing
Molex 2139
or equivalent
Terminal
Molex 2478
or equivalent
Block Diagram
fosc : 100KHz
RECTIFIERS
&
FILTER
EMI
FILTER
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
PWM
CONTROL
+V
-V
DETECTION
CIRCUIT
FG
CROWBAR
OVP
Derating Curve
Static Characteristics
OUTPUT VOLTAGE (V)
100
80
LOAD (%)
60
40
20
350
28
300
24
250
20
200
16
150
12
100
50
8
-10
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
(HORIZONTAL)
OUTPUT RIPPLE (mVp-p)
Ta=25
32
60
80
100
120
140
160
180
200
220
240
260
INPUT VOLTAGE (V) 60Hz
File Name:MPS-30-SPEC 2008-03-25