PLN-30 30W Single Output Switching Power Supply series Features : Universal AC input / Full range Fully isolated plastic case with IP64 level Built-in constant current limiting circuit with adjustable OCP level Protections:Short circuit/Over load/Over voltage/Over temperature Built-in active PFC function IP64 design for indoor or outdoor installations Cooling by free air convection 100% full load burn-in test High reliability Suitable for LED lighting and moving sign applications 2 years warranty F 110 M SELV M EQUIVALENT SPECIFICATION MODEL DC VOLTAGE ( except for 48V ) IP64 PLN-30-9 PLN-30-12 PLN-30-15 PLN-30-20 PLN-30-24 PLN-30-27 PLN-30-36 PLN-30-48 9V 12V 15V 20V 24V 27V 36V 48V 8.4 ~ 12V 10.5 ~ 15V 14 ~ 20V 16.8 ~ 24V 18.9 ~ 27V 25.2 ~ 36V 33.6 ~ 48V 2A 1.5A 1.25A 1.12A 0.84A 0.63A CONSTANT CURRENT REGION Note.6 6.3 ~ 9V OUTPUT LPS RATED CURRENT 3.3A 2.5A CURRENT RANGE 0 ~ 3.3A 0 ~ 2.5A 0 ~ 2A 0 ~ 1.5A 0 ~ 1.25A 0 ~ 1.12A 0 ~ 0.84A 0 ~ 0.63A RATED POWER 29.7W 30W 30W 30W 30W 30.24W 30.24W 30.24W 2Vp-p 2.6Vp-p 2Vp-p 2.6Vp-p 2.3Vp-p 4.5Vp-p 3.7Vp-p 85% 86% 86% 40 ~ 50V 53 ~ 63V RIPPLE & NOISE (max.) Note.2 2.6Vp-p VOLTAGE ADJ. RANGE Note.5 10%. Can be adjusted by internal potential meter SVR1 CURRENT ADJ. RANGE Note.5 3% ~ -25%. Can be adjusted by internal potential meter SVR2 VOLTAGE TOLERANCE Note.3 10% LINE REGULATION 3.0% 10% LOAD REGULATION INPUT SETUP, RISE TIME 1500ms, 150ms / 230VAC 3000ms, 150ms / 115VAC at full load VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR PF>0.9/230VAC EFFICIENCY(Typ.) 80% 83% AC CURRENT INRUSH CURRENT(max.) 0.4A/115VAC 40A/230VAC 0.2A/230VAC Note.4 SHORT CIRCUIT PROTECTION PF>0.95/115VAC at full load 84% 84% 85% 0.5mA / 240VAC LEAKAGE CURRENT OVER CURRENT 127 ~ 370VDC OVER VOLTAGE OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT 110 ~ 120% Protection type : Constant current limiting, recovers automatically after fault condition is removed Hiccup mode, recovers automatically after fault condition is removed. 10 ~ 14V 14 ~ 16V 17 ~ 22V 23 ~ 26V 27 ~ 34V 31 ~ 35V Protection type : Shut down o/p voltage, re-power on to recover 90 10 (TSW1) Protection type : Shut down o/p voltage, re-power on to recover -30 ~ +50 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +80 0.06%/ , 10 ~ 95% RH (0 ~ 50 ) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes SAFETY STANDARDS TUV EN61347-1, EN61347-2-13, CAN/CSA C22.2 No. 223-M91(except for 48V), IP64 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH EMC EMI CONDUCTION & RADIATION Compliance to EN55015 Compliance to EN61000-3-2 Class C (>80% load), Class D (>50% load) ; EN61000-3-3 HARMONIC CURRENT EMS IMMUNITY MTBF OTHERS DIMENSION PACKING NOTE Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61547, light industry level, criteria A 621.4Khrs min. MIL-HDBK-217F (25 145*47*30mm (L*W*H) 0.22Kg; 60pcs/14.2Kg/1.25CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Please refer to OLP characteristics. 5. Output voltage can be adjusted through the SVR1 on the PCB; limit of output constant current level can be adjusted through the SVR2 on the PCB. 6. Constant current operation region is within 70% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. File Name:PLN-30-SPEC 2008-08-18 PLN-30 30W Single Output Switching Power Supply Mechanical Specification Case No.964A series Unit:mm 145 9.83 4.38 2-R2.25 +V(Red) -V(Black) AC/L(Brown) AC/N(Blue) 18AWG 2C 9.83 47 320 10 320 10 18AWG 2C 30 4.38 Output voltage and current adjustment : remove the upper case and adjust through SVR1 & SVR2 shown in the diagram. SVR2 SVR1 SVR1 Output voltage adjustment SVR2 Output current adjustment Block Diagram fosc : 39KHz(115VAC) 53KHz(230VAC) EMI FILTER & RECTIFIERS I/P RECTIFIERS & FILTER POWER SWITCHING +V -V DETECTION CIRCUIT O.L.P. PWM & PFC CONTROL O.C.P. O.V.P. OLP Characteristics Derating Curve 100 100 Constant Current VO (%) 80 LOAD (%) 60 70 (max.) 40 Hiccup Mode 20 -30 -25 -5 0 15 30 40 AMBIENT TEMPERATURE ( ) 50 60 0 50 100 110 120 IO(%) File Name:PLN-30-SPEC 2008-08-18