PLP-45 45W Single Output LED Power Supply series Features : Universal AC input / Full range Protections: Short circuit / Overload / Over voltage Built-in active PFC function Cooling by free air convection Output current level adjustable 100% full load burn-in test High reliability Suitable for built-in applications of LED lighting 2 years warranty SELV EQUIVALENT ( SPECIFICATION MODEL DC VOLTAGE PLP-45-12 PLP-45-24 PLP-45-48 12V 24V 48V 18 ~ 24V 36 ~ 48V 0.95A CONSTANT CURRENT OPERATION VOLTAGE Note.5 9 ~ 12V OUTPUT RATED CURRENT 3.8A 1.9A CURRENT RANGE 0 ~ 3.8A 0 ~ 1.9A 0 ~ 0.95A RATED POWER 45.6W 45.6W 45.6W 3.8Vp-p 4.8Vp-p 1.425 ~ 1.9A 0.715 ~ 0.95A RIPPLE & NOISE (max.) Note.2 4.2Vp-p CURRENT ADJ. RANGE 2.85 ~ 3.8A VOLTAGE TOLERANCE Note.3 10% LINE REGULATION 3.0% 5.0% LOAD REGULATION 1000ms / 230VAC 2000ms / 115VAC at full load SETUP TIME VOLTAGE RANGE INPUT except for 48V ) Note.4 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR PF 0.9 at 75 ~ 100% load, 115VAC / 230VAC EFFICIENCY(Typ.) 86% AC CURRENT INRUSH CURRENT(max.) 0.6A/115VAC 42A/230VAC LEAKAGE CURRENT <0.75mA / 240VAC OVER CURRENT Note.5 PROTECTION SHORT CIRCUIT OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT 89% 89% 0.3A/230VAC 100 ~ 110% Protection type : Constant current limiting, recovers automatically after fault condition is removed Protection type : Hiccup mode, recovers automatically after fault condition is removed 15 ~ 18V 28 ~ 35V 57 ~ 63V Protection type : Shut down o/p voltage, re-power on to recover -30 ~ +70 (Refer to output load derating curve) 20 ~ 95% RH non-condensing -40 ~ +80 , 10 ~ 95% RH 0.03%/ (0 ~ 50 ) VIBRATION 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes SAFETY STANDARDS TUV EN61347-1, EN61347-2-13 approved, design refer to UL60950-1 WITHSTAND VOLTAGE I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH EMC EMI CONDUCTION & RADIATION Compliance to EN55015 HARMONIC CURRENT EMS IMMUNITY MTBF OTHERS DIMENSION PACKING NOTE Compliance to EN61000-3-2 Class C( 75% load); EN61000-3-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024,EN61547, light industry level, criteria A 586.5Khrs min. MIL-HDBK-217F (25 ) 101.6*50.8*28mm (L*W*H) 0.16Kg; 96pcs/16.4Kg/0.89CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor, direct connecting to LED's is not suggested for models with "RIPPLE & NOISE" > 10% and using additional drivers is highly recommended. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltage. Please check the derating curve for more details. 5. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. 6. Heat sink HS1,HS2 can not be shorted. 7. Heat sink HS1 must have safety isolation distance with system case. File Name:PLP-45-SPEC 2009-10-06 PLP-45 45W Single Output LED Power Supply Mechanical Specification series Unit:mm 101.6 3.175 . 50.8 . 44.45 3.175 95.25 HS1 HS2 FS1 1 2 3 CN1 CN2 SVR1 1 2 4- 28 3.2 3max. 1.HS1,HS2 can not be shorted. 2.HS1 must have safety isolation distance with system case. AC Input Connector (CN1) : JST B3P-VH or equivalent Pin No. 1 2 3 Assignment AC/L No Pin AC/N DC Output Connector (CN2) : JST B2P-VH or equivalent Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent Pin No. 1 2 Assignment +V -V Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent Block Diagram fosc : 90KHz(115VAC) 120KHz(230VAC) EMI FILTER & RECTIFIERS I/P RECTIFIERS & FILTER POWER SWITCHING FG +V -V DETECTION CIRCUIT O.L.P. PWM & PFC CONTROL O.C.P. O.V.P. Derating Curve Static Characteristics Ta:25 100 100 90 80 80 70 50 LOAD (%) LOAD (%) 60 40 20 -30 -25 -5 0 20 40 50 AMBIENT TEMPERATURE ( ) 60 70 (HORIZONTAL) 60 50 40 90 100 125 135 145 155 165 175 180 200 230 264 INPUT VOLTAGE (V) 60Hz File Name:PLP-45-SPEC 2009-10-06