P P T- 1 2 5 125W Triple Output with PFC Function series Features : Universal AC input / Full range Built-in active PFC function Protections: Short circuit / Overload / Over voltage PWM control and regulated High power density 6.117W/inch3 LED indicator for power on 100% full load burn-in test 125W with 18CFM FAN 5"x3" compact size 3 years warranty SPECIFICATION MODEL PPT-125A PPT-125B PPT-125C PPT-125D OUTPUT NUMBER CH1 CH2 CH3 CH1 CH2 CH3 CH1 CH2 CH3 CH1 CH2 DC VOLTAGE 3.3V 5V 12V 5V 12V -12V 5V 15V -15V 5V 24V 12V RATED CURRENT 10A 8A 0.5A 11.5A 3A 0.5A 11A 2.5A 0.5A 7A 2.5A 0.5A CURRENT RANGE (convection) 1 ~ 10A 0.8 ~ 8A 0.05 ~ 0.5A 1 ~ 11.5A 0.3 ~ 3A 0.05 ~ 0.5A 1 ~ 11A 0.25 ~ 2.5A 0.05 ~ 0.5A 1 ~ 7A CH3 0.25 ~ 2.5A 0.05 ~ 0.5A CURRENT RANGE (18CFM FAN) 1 ~ 12.5A 0.8 ~ 10A 0.05 ~ 0.63A 1 ~ 14.38A 0.3 ~ 3.75A 0.05 ~ 0.63A 1 ~ 13.75A 0.25 ~ 3.13A 0.05 ~ 0.63A 1 ~ 8.75A 0.25 ~ 3.13A 0.05 ~ 0.63A OUTPUT RATED POWER (convection) 79W 99.5W 100W 101W RATED POWER (18CFM FAN) 98.8W 124.46W 125.15W 126.43W RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 120mVp-p 100mVp-p 120mVp-p 120mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 240mVp-p 120mVp-p VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 INPUT CH1:3.13 ~ 3.46V 3.0% 5.0% CH1:4.75 ~ 5.25V 3.0% 5.0% 6.0% 6.0% CH1:4.75 ~ 5.25V 3.0% 5.0% 6.0% CH1:4.75 ~ 5.25V 3.0% 5.0% 6.0% LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 3.0% 3.0% 5.0% 3.0% 3.0% 5.0% 3.0% 3.0% 5.0% 3.0% 3.0% 5.0% SETUP, RISE TIME 1000ms, 30ms/230VAC 2000ms, 30ms/115VAC at full load HOLD UP TIME (Typ.) 24ms/230VAC VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47~63Hz POWER FACTOR (Typ.) PF>0.93/230VAC EFFICIENCY (Typ.) 75% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.7A/115VAC 0.75A/230VAC COLD START 24A/230VAC 24ms/115VAC at full load 127 ~ 370VDC PF>0.98/115VAC at full load 78% 78% LEAKAGE CURRENT <2mA / 240VAC OVERLOAD 130 ~ 160% rated output power Protection type : Fold back current limiting, recovers automatically after fault condition is removed PROTECTION OVER VOLTAGE WORKING TEMP., HUMIDITY WORKING TEMP. ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE CH1:3.6 ~ 4.45V CH1:5.75 ~ 6.75V CH1:5.75 ~ 6.75V Protection type : Hiccup mode, recovers automatically after fault condition is removed -20 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 0.05%/ 78% CH1:5.75 ~ 6.75V , 10 ~ 95% RH (0 ~ 50 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 EMC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B / 70% RH (Note 4) OTHERS HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY MTBF Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A 94.7Khrs min. MIL-HDBK-217F (25 ) 127*76.2*34.6mm (L*W*H) 0.37Kg; 36pcs/14.3Kg/0.79CUFT DIMENSION PACKING NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Heat Sink HS1,HS2 & HS3 can not be shorted. File Name:PPT-125-SPEC 2008-10-22 P P T- 1 2 5 125W Triple Output with PFC Function Mechanical Specification series Unit:mm 127 115.6 6.4 5 HS3 SVR1 FS1 T2A 250VAC 64.8 76.2 HS1 1 2 3 CN1 LED1 1 2 3 4 5 6 7 8 9 10 HS2 CN4 43. Pin No. 1 2 3 Assignment AC/L No Pin AC/N Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent 5 Air flow direction AC Input Connector (CN1) : JST B3P-VH or equivalent DC Output Connector (CN4) : JST B5P-VH*2 or equivalent 34.6 Pin No. 1 2,3 4~8 9,10 Assignment CH3 CH2 GND CH1 Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent 3max. HS1, HS2 & HS3 can not be shorted Block Diagram fosc : 100KHz EMI FILTER & RECTIFIERS I/P RECTIFIERS & FILTER POWER SWITCHING PFC CIRCUIT RECTIFIERS & FILTER PWM & PFC CONTROL FG V3 REGULATOR RECTIFIERS & FILTER V2 +5V COM DETECTION CIRCUT O.V.P. Derating Curve Output Derating VS Input Voltage 100 125 Forced air 18CFM 90 100 80 70 70 50 60 LOAD(%) LOAD (%) Free air Convection 40 20 -20 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 70 (HORIZONTAL) 50 40 85 100 115 135 155 264 INPUT VOLTAGE (V) 60Hz File Name:PPT-125-SPEC 2008-10-22