P T- 6 5 0 3 65W Triple Output with 3.3V output Features : Universal AC input / Full range Protections:Short circuit/Over load/Over voltage Cooling by free air convection 100% full load burn-in test Fixed switching frequency at 65KHz 2 years warranty SPECIFICATION MODEL PT-6503 OUTPUT NUMBER OUTPUT INPUT DC VOLTAGE CH1 3.3V CH2 5V CH3 12V RATED CURRENT 6A 6A 1A CURRENT RANGE 0 ~ 7A 0.2 ~ 10A 0 ~ 1.2A RATED POWER Total power max. 61.8W(CH1+CH2 max. 54W) RIPPLE & NOISE (max.) Note.2 50mVp-p VOLTAGE ADJ. RANGE 3.0% +4,-2% 8.0% LINE REGULATION 1.0% 1.0% 2.0% 3.0% 8.0% LOAD REGULATION SETUP, RISE TIME 3.0% 800ms, 50ms at full load HOLD TIME (Typ.) 60ms at full load VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 72% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.8A/115VAC OVER LOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE EMI CONDUCTION & RADIATION EMC (Note 4) HARMONIC CURRENT 127 ~ 370VDC 0.9A/230VAC COLD START 20A/115V <1mA / 240VAC 40A/230V 120 ~ 160% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 5.75 ~ 6.75V on +5V Protection type : Hiccup mode, recovers automatically after fault condition is removed -10 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, Period for 60min.each along X, Y, Z axes UL60950-1, TUV EN60950-1 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC 1min. I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,11 Light industry level, criteria A MTBF 222Khrs min. MIL-HDBK-217F (25 127*76*42mm (L*W*H) 0.28Kg; 54pcs/16.2Kg/1.35CUFT DIMENSION PACKING NOTE 100mVp-p VOLTAGE TOLERANCE Note.3 LEAKAGE CURRENT OTHERS 50mVp-p CH1: 3 ~ 3.6V ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Mounting holes M1 and M2 should be grounded for EMI purposes. File Name:PT-6503-SPEC 2006-01-27 P T- 6 5 0 3 65W Triple Output with 3.3V output Mechanical Specification Unit:mm 127 5.6 5.6 115.8 FG M2 1 2 3 4 5 6 7 8 64.8 76 M1 CN1 1 CN2 2 AC FUSE F4A/250V 3. 8 42 4- AC Input Connector (CN1) : Molex 5277-02 or equivalent Pin No. 1 2 Assignment AC/N AC/L Mating Housing Terminal Molex 5195 or equivalent Molex 5194 or equivalent DC Output Connector (CN2) : Molex 5273-08 or equivalent Pin No. Assignment 1,2 +5V 3,4,5 COM 6 +V 7,8 +3.3V Mating Housing Terminal Molex 5195 or equivalent Molex 5194 or equivalent Block Diagram fosc : 65KHz RECTIFIERS & FILTER EMI FILTER I/P POWER SWITCHING RECTIFIERS & FILTER +V RECTIFIERS & FILTER +5V DC/DC CONNERTER +3.3V FG COM DETECTION CIRCUIT PWM CONTROL O.L.P. O.V.P. Static Characteristics Output Derating Ta=25 100 LOAD (%) OUTPUT VOLTAGE (V) 2 1 1 Convection 2 Forced Air (18CFM min.) 40 20 -10 300 +5V 80 60 +12V 5.2 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 (HORIZONTAL) 11 250 5.0 10 4.8 9 4.6 8 4.4 7 4.2 6 4.0 +3.3V 200 150 100 +12V +5V +3.3V 60 80 100 120 140 160 180 200 220 240 50 OUTPUT RIPPLE (mVp-p) 12 25 260 INPUT VOLTAGE (V) 60Hz File Name:PT-6503-SPEC 2006-01-27