MEANWELL PT

P T- 6 5 0 3
65W Triple Output with 3.3V output
Features :
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 65KHz
2 years warranty
SPECIFICATION
MODEL
PT-6503
OUTPUT NUMBER
OUTPUT
INPUT
DC VOLTAGE
CH1
3.3V
CH2
5V
CH3
12V
RATED CURRENT
6A
6A
1A
CURRENT RANGE
0 ~ 7A
0.2 ~ 10A
0 ~ 1.2A
RATED POWER
Total power max. 61.8W(CH1+CH2 max. 54W)
RIPPLE & NOISE (max.) Note.2 50mVp-p
VOLTAGE ADJ. RANGE
3.0%
+4,-2%
8.0%
LINE REGULATION
1.0%
1.0%
2.0%
3.0%
8.0%
LOAD REGULATION
SETUP, RISE TIME
3.0%
800ms, 50ms at full load
HOLD UP TIME (Typ.)
60ms at full load
VOLTAGE RANGE
90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
72%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
1.8A/115VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note 4)
EMC EMISSION
EMC IMMUNITY
MTBF
DIMENSION
PACKING
NOTE
100mVp-p
VOLTAGE TOLERANCE Note.3
LEAKAGE CURRENT
OTHERS
50mVp-p
CH1: 3 ~ 3.6V
127 ~ 370VDC
0.9A/230VAC
COLD START 20A/115V
<1mA / 240VAC
40A/230V
120 ~ 160% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.75 ~ 6.75V on +5V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-10 ~ +60 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC 1min.
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,11, light industry level, criteria A
222Khrs min. MIL-HDBK-217F (25
127*76*42mm (L*W*H)
0.28Kg; 54pcs/16.2Kg/1.35CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Mounting holes M1 and M2 should be grounded for EMI purposes.
6. Heat Sink HS1,HS2 can not be shorted.
File Name:PT-6503-SPEC 2011-08-18
P T- 6 5 0 3
65W Triple Output with 3.3V output
Mechanical Specification
Unit:mm
127
5.6
5.6
115.8
FG
HS1
M2
1
2
3
4
5
6
7
8
64.8
76
M1
HS2
CN1
1
CN2
2
FS1
AC FUSE
F4A/250V
3.
8
42
4-
AC Input Connector (CN1) : Molex 5277-02 or equivalent
Pin No.
1
2
Assignment
AC/N
AC/L
Mating Housing
Terminal
Molex 5195
or equivalent
Molex 5194
or equivalent
DC Output Connector (CN2) : Molex 5273-08 or equivalent
Pin No. Assignment
1,2
+5V
3,4,5
COM
6
+V
7,8
+3.3V
HS1,HS2 can not be shorted
Mating Housing
Terminal
Molex 5195
or equivalent
Molex 5194
or equivalent
Block Diagram
fosc : 65KHz
RECTIFIERS
&
FILTER
EMI
FILTER
I/P
POWER
SWITCHING
RECTIFIERS
&
FILTER
+V
RECTIFIERS
&
FILTER
+5V
DC/DC
CONNERTER
+3.3V
FG
COM
DETECTION
CIRCUIT
PWM
CONTROL
O.L.P.
O.V.P.
Static Characteristics
12
100
LOAD (%)
OUTPUT VOLTAGE (V)
2
1
1 Convection
2 Forced Air (18CFM min.)
40
20
-10
300
+5V
80
60
+12V
5.2
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
(HORIZONTAL)
11
250
5.0
10
4.8
9
4.6
8
4.4
7
4.2
6
4.0
+3.3V
200
150
100
+12V
+5V
+3.3V
60
80
100
120 140
160
180
200
220
240
50
OUTPUT RIPPLE (mVp-p)
Derating Curve
25
264
INPUT VOLTAGE (V) 60Hz
File Name:PT-6503-SPEC 2011-08-18