SCN-2K0 2000W Single Output With Parallel Function series ■ Features : $AC input 200~260VAC,3ψ 3wires(other system available) $Protections: Short circuit / Overload / Over voltage / Over temp. $High reliability; Low ripple noise $Built-in remote sense function $Built-in remote ON-OFF control $Built-in parallel operation function $Can adjust from 20~100% output voltage by external control 1-5V $Forced air cooling by built-in DC fan $Case coating with paint $2 years warranty SPECIFICATION ORDER NO. SAFETY MODEL NO. DC VOLTAGE SCN-2K0-12 SCN-2K0-15 SCN-2K0-24 SCN-2K0-48 2K0S-N005 5V 2K0S-N012 2K0S-N015 2K0S-N024 2K0S-N048 12V 15V 24V 48V 167A 134A 83.5A 42A CURRENT RANGE 250A 0 ~ 250A 0 ~ 167A 0 ~ 134A 0 ~ 83.5A 0 ~ 42A RATED POWER 1250W 2004W 2010W 2004W 2016W 180mVp-p 200mVp-p 240mVp-p 480mVp-p RATED CURRENT OUTPUT SCN-2K0-05 RIPPLE & NOISE (max.) Note.2 150mVp-p VOLTAGE ADJ. RANGE ± VOLTAGE TOLERANCE Note.3 ± LINE REGULATION LOAD REGULATION ± 5.0% typical adjustment by potentiometer 3.0% ± 2.0% ± 0.5% 2.5% ± 0.5% ± 1.5% 20~100% adjustment by 1~5VDC external control ± 2.0% ± 1.0% ± ± 0.5% 1.5% ± ± ± 1.0% 0.5% ± 0.5% 0.5% ± 0.5% SETUP, RISE, HOLD UP TIME 800ms, 50ms, 16ms at full load INPUT VOLTAGE RANGE 200 ~ 260VAC, 3ψ , 3wires FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 78% 10A / 230VAC AC CURRENT INRUSH CURRENT (max.) OVERLOAD ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE OTHERS NOTE ISOLATION RESISTANCE 86% 120A / 230VAC 5mA/ 240VAC WORKING TEMP. WORKING HUMIDITY (Note. 4) 85% 110 ~ 135% rated output power Protection type : Current limiting, delay shut down o/p voltage, re-power on to recover OVER TEMPERATURE EMC 84% LEAKAGE CURRENT (max.) PROTECTION OVER VOLTAGE SAFETY & 84% 110 ~ 135% follow to output set up point Protection type : Shut down o/p voltage, re-power on to recover >100℃ / measure by heat sink, near transformer Protection type : Shut down o/p voltage, re-power on to recover -10 ~ +65℃(Refer to output load derating curve) 20% ~ 90% RH non-condensing -20 ~ +85℃, 10 ~ 95% RH ± 0.04% / ℃ (0 ~ 50℃) 10 ~ 200Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes Design refer to UL1950, CSA22.2, IEC60950 I/P-O/P:1500VAC, I/P-FG:1500VAC I/P-O/P, I/P-FG, >100M Ohms / 500VDC / 25℃/ 70% RH EMI CONDUCTION & RADIATION Design refer to FCC part 15 class A HARMONIC CURRENT EMS IMMUNITY MTBF ---- DIMENSION PACKING SPECIAL FUNCTION 320*212*134mm (L*W*H) 9.0kg; 1pcs/ 10kg / CARTON DC voltage adj., Remote sensing, remote control, parallel operation (refer to terminal instruction manual) ---30khrs min. MIL-HDBK-217F (25℃) 1.All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient. 2.Tolerence: includes set up tolerance, line regulation, load regulation. 3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. File Name:SCN-2K0-SPEC 2007-11-01 SCN-2K0 2000W Single Output With Parallel Function series 134 10-M3X0.5 TERMINAL BLOCK 4M4X0.7 TERMINAL BLOCK FOR CONTROL SIGNAL FOR 3ψ 3W AC INPUT Mechanical Specification 320.0 212 Air flow direction Air flow direction 6 TYP. 6-M6 SCREW FOR DC OUTPUT 180 30 MAX. 4-M4X0.7 MOUNTING HOLE FOR USER 12 290 Derating Curve External DC Control VS Output Voltage Vout 100 OUTPUT VOLTAGE (%) LOAD (%) 100 50 -10 O.V.P. 0 10 20 30 40 Ta (℃) 50 60 80 non-linear 60 40 20 V 1 2 3 4 5 EXTERNAL VOLTAGE(Typical) File Name:SCN-2K0-SPEC 2007-11-01 SCN-2K0 2000W Single Output With Parallel Function series Control terminal instruction manual LOAD LOAD M+ VS+ VSMVCI VCO GND PAR GND INH M+ VS+ VSMVCI VCO GND PAR GND INH M+ VS+ VSMVCI VCO GND PAR GND INH USING INTERNAL VOLTAGE CONTROL LOAD ON/OFF CONTROL SWITCH H:ON L:DFF ON/OFF CONTROL BY TRANSISTOR LOAD M+ VS+ VSMVCI VCO GND PAR GND INH M+ VS+ VSMVCI VCO GND PAR GND INH DC1-5V OUTPUT VOLTAGE ADJUST WITH DC 1-5V REMOTE SENSING LOAD M+ VS+ VSMVCI VCO GND PAR GND INH M+ VS+ VSMVCI VCO GND PAR GND INH M+ VS+ VSMVCI VCO GND PAR GND INH PARALLEL OPERATION WITH REMOTE SENEING LOAD M+ VS+ VSMVCI VCO GND PAR GND INH M+ VS+ VSMVCI VCO GND PAR GND INH M+ VS+ VSMVCI VCO GND PAR GND INH PARALLEL OPERATION File Name:SCN-2K0-SPEC 2007-11-01 SCN-2K0 2000W Single Output With Parallel Function series FIG. A: 3ψ3W 220VAC SYSTEM (STANDARD MODEL FOR STOCK) R R L1 N1 220V S L2 N2 T L3 N3 S FG1 FG2 FG3 220V N (NC) FG T FIG. B: 1ψ220VAC SYSTEM L R L1 N1 220V S L2 N2 T L3 N3 N FG1 FG2 FG3 N FG FIG. C: 3ψ4W 220/380VAC SYSTEM R R L1 N1 220V S L2 N2 T N L3 N3 FG1 FG2 FG3 N S 380V FG T FIG. D: 3ψ4W 190/110VAC SYSTEM R 110V R L1 N1 S N L2 N2 (N.C.) T L3 N3 S FG1 FG2 FG3 190V N (NC) FG T File Name:SCN-2K0-SPEC 2007-11-01