MEANWELL SCN-800

SCN-800
800W Single Output With Parallel Function
series
Features :
AC input range selected by switch
Protections: Short circuit / Overload / Over voltage / Over temp.
High reliability/ Low ripple noise
Built-in remote sense function
Built-in remote ON-OFF control
Built-in parallel operation function
Can adjust from 20~100% output voltage by external control 1-5V
Forced air cooling by built-in DC fan
Case coating with paint
2 years warranty
SPECIFICATION
ORDER NO.
OUTPUT
SCN-800-12
SCN-800-15
SCN-800-24
SAFETY MODEL NO.
800S-N012
800S-N015
800S-N024
800S-N048
DC VOLTAGE
12V
15V
24V
48V
RATED CURRENT
66A
54A
33A
16.6A
CURRENT RANGE
0 ~ 66A
0 ~ 54A
0 ~ 33A
0 ~ 16.6A
RATED POWER
792W
810W
792W
796W
150mVp-p
240mVp-p
480mVp-p
RIPPLE & NOISE (max.) Note.2 150mVp-p
VOLTAGE ADJ. RANGE
5.0% typical adjustment by potentiometer
1.0%
VOLTAGE TOLERANCE Note.3 1.0%
20~100% adjustment by 1~5VDC external control
1.0%
SCN-800-48
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
0.5%
0.5%
0.5%
0.5%
SETUP, RISE, HOLD UP TIME 800ms, 50ms, 16ms at full load
90 ~ 130VAC / 180 ~ 260VAC selected by switch, 260 ~ 370VDC
VOLTAGE RANGE
INPUT
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
80%
17A / 115VAC 9A / 230VAC
AC CURRENT
INRUSH CURRENT (max.)
81%
3.5mA / 240VAC
OVERLOAD
110 ~ 135% rated output power
Protection type : Current limiting, delay shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
WORKING TEMP.
WORKING TEMP., HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
110 ~ 135% follow to output set up point
Protection type : Shut down o/p voltage, re-power on to recover
>100
/ measure by heat sink, near transformer
Protection type : Shut down o/p voltage, re-power on to recover
-10 ~ +65 (Refer to output load derating curve)
20% ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.04% / (0 ~ 50 )
10 ~ 200Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
Design refer to UL1950, CSA22.2, IEC60950
I/P-O/P, I/P-FG:1500VAC
I/P-O/P, I/P-FG, >100M Ohms / 500VDC / 25
SAFETY &
ISOLATION RESISTANCE
EMC
EMI CONDUCTION & RADIATION Design refer to FCC part 15 class A
(Note. 4)
HARMONIC CURRENT
---EMS IMMUNITY
----
NOTE
87%
60A / 230VAC
LEAKAGE CURRENT (max.)
PROTECTION OVER VOLTAGE
OTHERS
85%
/ 70% RH
MTBF
120khrs min. MIL-HDBK-217F (25
DIMENSION
PACKING
SPECIAL FUNCTION
291*132*68mm (L*W*H)
2.3kg; 8pcs/ 24kg /CARTON
DC voltage adj., Remote sensing, remote control, parallel operation (refer to terminal instruction manual)
)
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.Tolerence: includes set up tolerance, line regulation, load regulation.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:SCN-800-SPEC 2007-11-01
SCN-800
800W Single Output With Parallel Function
Mechanical Specification
series
Unit:mm
291
200
50.5
#6-32-4
M3(NUT)x3H-4
AC INPUT
30
VS+
VSVCI
VCO
GND
PAR
GND
INH
N FG
68
L
41
15.5
199.5
V ADJ
15
LED
POS+
NEG-
291
32
9.5
M3(NUT)x3H-4
115
M6
7.5
NEG
AC INPUT
BOTTOM SIDE
POS
DC OUTPUT
Air flow
direction
132
250
9
Derating Curve
External DC Control VS Output Voltage
O.V.P.
Vout
100
OUTPUT VOLTAGE (%)
LOAD (%)
100
50
-10
0
10
20
30
Ta (
40
)
50
60
80
non-linear
60
40
20
V
1
2
3
4
5
EXTERNAL VOLTAGE(Typical)
File Name:SCN-800-SPEC 2007-11-01
SCN-800
800W Single Output With Parallel Function
series
Control terminal instruction manual
LOAD
LOAD
VS+
VSVCI
VCO
GND
PAR
GND
INH
VS+
VSVCI
VCO
GND
PAR
GND
INH
USING INTERNAL VOLTAGE CONTROL
LOAD
VS+
VSVCI
VCO
GND
PAR
GND
INH
ON/OFF CONTROL BY SWITCH
REMOTE SENSING
LOAD
LOAD
VS+
VSVCI
VCO
GND
PAR
GND
INH
ON/OFF SWITCH
VS+
VSVCI
VCO
GND
PAR
GND
INH
H:ON
L:OFF
DC 1-5V
OUTPUT VOLTAGE ADJUST WITH DC 1-5V
ON/OFF CONTROL BY TRANSISTOR
LOAD
VS+
VSVCI
VCO
GND
PAR
GND
INH
VS+
VSVCI
VCO
GND
PAR
GND
INH
VS+
VSVCI
VCO
GND
PAR
GND
INH
PARALLEL OPERATION WITH REMOTE SENSING
LOAD
VS+
VSVCI
VCO
GND
PAR
GND
INH
VS+
VSVCI
VCO
GND
PAR
GND
INH
VS+
VSVCI
VCO
GND
PAR
GND
INH
PARALLEL OPERATION