MEANWELL SDR-120-24

SDR-120 series
120W Single Output Industrial DIN RAIL with PFC Function
Features :
High efficiency 91% and low power dissipation
150% peak load capability
Built-in active PFC function, PF>0.93
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
UL 508 (industrial control equipment) approved
EN61000-6-2(EN50082-2) industrial immunity level
Built-in DC OK relay contact
100% full load burn-in test
3 years warranty
SE
PQ
M
IF
47
SPECIFICATION
MODEL
OUTPUT
SDR-120-12
SDR-120-24
SDR-120-48
DC VOLTAGE
12V
24V
48V
RATED CURRENT
10A
5A
2.5A
CURRENT RANGE
0 ~ 10A
0 ~ 5A
0 ~ 2.5A
RATED POWER
120W
120W
120W
PEAK CURRENT
15A
7.5A
3.75A
PEAK POWER Note.6
180W (3 sec.)
RIPPLE & NOISE (max.) Note.2 100mVp-p
100mVp-p
120mVp-p
VOLTAGE ADJ. RANGE
24 ~ 28V
1.0%
48 ~ 55V
1.0%
12 ~ 14V
VOLTAGE TOLERANCE Note.3 1.0%
LINE REGULATION
0.5%
0.5%
0.5%
LOAD REGULATION
1.0%
1.0%
1.0%
1500ms, 60ms/230VAC
SETUP, RISE TIME
20ms/230VAC
HOLD UP TIME (Typ.)
VOLTAGE RANGE
INPUT
Note.7 88 ~ 264VAC
3000ms, 60ms/115VAC at full load
20ms/115VAC at full load
124 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
0.93/230VAC
89%
0.96/115VAC at full load
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
1.4A/115VAC
35A/115VAC
0.7A/230VAC
70A/230VAC
LEAKAGE CURRENT
<1mA / 240VAC
Normally works within 110 ~ 150% rated output power for more than 3 seconds and then shut down o/p voltage
OVERLOAD
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
91%
90.5%
>150% rated power, constant current limiting with auto-recovery within 3 seconds and shut down o/p voltage after 3 seconds
14 ~ 17V
29 ~ 33V
Protection type : Shut down o/p voltage, re-power on to recover
95
5
56 ~ 65V
(TSW : detect on heatsink of power switch)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION DC OK REALY CONTACT RATINGS (max.) 60Vdc/0.3A, 30Vdc/1A, 30Vac/0.5A resistive load
-25 ~ +70 (Refer to output load derating curve)
WORKING TEMP.
20 ~ 95% RH non-condensing
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
-40 ~ +85
, 10 ~ 95% RH
0.03%/ (0 ~ 50
Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
UL508, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25
SAFETY & ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
EMC
(Note 4)
Compliance to EN61000-3-2,-3
HARMONIC CURRENT
EMS IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
NOTE
O/P-DC OK:0.5KVAC
/ 70% RH
Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, heavy industry level,
criteria A, SEMI F47 approved
289.9Khrs min. MIL-HDBK-217F (25
40*125.2*113.5mm (W*H*D)
0.67Kg; 20pcs/14.4Kg/1.16CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power.
In case the adjacent device is a heat source, 15mm clearance is recommended.
6. 3 seconds max., please refer to peak loading curves.
7. Derating may be needed under low input voltage. Please check the derating curve for more details.
File Name:SDR-120-SPEC 2009-08-14
120W Single Output Industrial DIN RAIL with PFC Function
SDR-120 series
Mechanical Specification
Unit:mm
113.5
Case No.992A
125.2
TB2
40
DC OK
+V ADJ.
1
2
3
DC OK
TB1
1
2
3
4
+
Terminal Pin No. Assignment (TB1)
35
Pin No.
1
2
3
Assignment
FG
AC/N
AC/L
Terminal Pin No. Assignment (TB2)
Pin No.
1,2
3
4
ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15
Assignment
Relay Contact
DC OUTPUT -V
DC OUTPUT+V
Block Diagram
DC OK
I/P
EMI FILTER
&
RECTIFIERS
POWER
SWITCHING
PFC
CIRCUIT
RECTIFIERS
&
FILTER
+V
-V
O.C.P.
U.V.P.
FG
PFC
CONTROL
O.L.P.
PWM & PFC
CONTROL
DETECTION
CIRCUIT
O.V.P.
DC OK Relay Contact
Contact Close
When the output voltage reaches the adjusted output voltage.
Contact Open
When the output voltage drop below 90% output voltage.
Contact Ratings (max.) 30V/1A resistive load
File Name:SDR-120-SPEC 2009-08-14
SDR-120 series
120W Single Output Industrial DIN RAIL with PFC Function
Peak Loading
(1)
(2)
180W
180W
120W
60W
100 sec.
3 sec.
15 sec. 3 sec.
Derating Curve
Output derating VS input voltage
Others
150
100
90
For 3 sec. (typ.)
125
12V
80
Others
70
Continuous
75
LOAD (%)
LOAD (%)
100
12V
60
-25
60
50
40
0
10
20
30
40
50 55 60
AMBIENT TEMPERATURE ( )
70 (VERTICAL)
88
100
110
135
155
230
264
INPUT VOLTAGE (V) 60Hz
File Name:SDR-120-SPEC 2009-08-14