MEDER ORD311

J2R0012-38-22
REED SWITCH
ORD311
Super Ultra Miniature Long Life
n GENERAL DESCRIPTION
The ORD311 is a small single-contact reed switch designed for general control of medium
level loads less than 100 V. The contacts are sealed within the glass tube with inert gas to maintain
contact reliability.
n FEATURES
(1) Reed switches are hermetically sealed within a glass tube with inert gas and do not receive
any influence from the external atmospheric environment.
(2) Quick response
(3) The structure comprises the operating parts and electrical circuits arranged coaxially. Reed
switches are suited to applications in radio frequency operation.
(4) Reed switches are compact and light weight.
(5) Superior corrosion resistance and wear resistance of the contacts assures stable switching
operation and long life.
(6) With a permanent magnet installed, reed switches economically and easily become
proximity switches.
n EXTERNAL DIMENSIONS (Unit: mm)
f0.33
MAX f1.8
MAX 7.0
35.8±0.3
n APPLICATIONS
l Automotive electronic devices
l Control equipment
l Communication equipment
l Measurement equipment
l Household appliances
167
l ORD311
n ELECTRICAL CHARACTERISTICS
Parameter
Pull-in Value (PI)
Rated value
Unit
10∼30
AT
5min
AT
Contact resistance (CR)
200max
mW
Breakdown voltage
250min
V
VDC
Insulation resistance
109min
W
Electrostatic capacitance
0.4max
pF
Drop-out Value (DO)
10
VA
Maximum switching voltage
DC
100( )
AC
V
Maximum switching current
1.0
A
Maximum carry current
0.5
A
Contact rating
(1) Drop-out Value vs. Pull-in Value
(2) Contact resistance
(Measurement length: 22mm)
99.9
Cumulative frequency percent (%)
Drop-out Value
AT
50
40
30
20
10
0
95
90
80
70
60
50
40
30
20
10
5
1
0.1
10
20
30
Pull-in Value
168
99
40
50
60
AT
100
120
140
Contact resistance
160
180
mW
ORD311 l
(4) Insulation resistance
(3) Breakdown voltage
(DC 100V)
Cumulative frequency percent (%)
99.9
Breakdown voltage
DC:V
400
300
200
100
0
10
20
30
40
50
Pull-in Value
AT
99
95
90
80
70
60
50
40
30
20
10
5
1
0.1
10
10
11
10
12
10
13
10
14
10
W
Insulation resistance
(5) Electrostatic capacitance
(1MHz)
Electrostatic capacitance
pF
0.4
0.3
0.2
0.1
0
10
20
30
Pull-in Value
40
50
60
AT
169
l ORD311
n OPERATING CHARACTERISTICS
Rated value
Unit
Operate time
0.3max
ms
Bounce time
0.3max
ms
Release time
0.05max
ms
13000±2000
Hz
500
Hz
Parameter
Resonant frequency
Maximum operating frequency
(2) Bounce time
(1) Operate time
(25Hz: 100AT energized)
(25Hz: 100AT energized)
99.9
Cumulative frequency percent (%)
ms
0.5
Operate time
0.4
0.3
0.2
0.1
0
99
95
90
80
70
60
50
40
30
20
10
5
1
0.1
10
20
30
40
50
0
AT
0.1
Pull-in Value
0.2
0.3
0.4
ms
Bounce time
(4) Resonant frequency
(3) Release time
Release time
(25Hz: 100AT energized)
ms
15
10
5
0
99
95
90
80
70
60
50
40
30
20
10
5
1
0.1
10
20
30
40
Drop-out Value
170
Cumulative frequency percent (%)
99.9
50
AT
11000
12000
13000
Resonant frequency
14000
Hz
ORD311 l
n MECHANICAL CHARACTERISTICS
(1) Lead tensile test (static load)
(2) Lead tensile strength
(2.27kg-10sec)
99.9
50
40
30
20
99
Cumulative frequency percent (%)
Pull-in Value • Drop-out Value
AT
60
PI
DO
10
95
90
80
70
60
50
40
30
20
10
5
1
0.1
0
2
4
Contact resistance
6
8
10kg
Breaking load
0
80
60
CR
40
Before test
After test
n ENVIRONMENTAL CHARACTERISTICS
(1) Temperature characteristics
%
40
Rate of change percent
30
CR
20
DO
10
PI
0
−10
−20
−30
−40
−20
0
20
40
60
80
100
120
℃
Temperature
171
l ORD311
(2) Temperature cycle
(3) Temperature and humidity cycle
-10℃∼+65℃
80%∼98%
(-55℃∼+125 ℃)
AT
60
Pull-in Value • Drop-out Value
Pull-in Value • Drop-out Value
AT
60
50
40
30
20
PI
DO
40
30
20
DO
0
0
mW
100
mW
100
80
60
PI
10
Contact resistance
Contact resistance
10
50
CR
Before test
80
CR
60
After test
Before test
(4) High temperature storage test
(5) Low temperature storage test
(-40℃-500H)
(+125℃-500H)
AT
60
Pull-in Value • Drop-out Value
Pull-in Value • Drop-out Value
AT
60
50
40
30
20
PI
50
40
30
20
PI
DO
DO
10
0
0
mW
100
mW
100
80
CR
Before test
172
Contact resistance
Contact resistance
10
60
After test
After test
80
60
CR
Before test
After test
ORD311 l
(6) Shock test
1) Electrical characteristics
2) Misoperation area
(open→close)
(30G: 11ms)
G
1500
50
40
Acceleration
Pull-in Value • Drop-out Value
AT
60
30
20
PI
1000
Misoperation
area
DO
10
500
Contact resistance
0
mW
100
80
60
0
10
20
30
40
50
60
AT
Pull-in Value
CR
Before test
After test
(7) Vibration test
(20G: 10∼1000Hz)
Pull-in Value • Drop-out Value
AT
60
50
40
30
20
PI
DO
10
Contact resistance
0
mW
100
80
60
CR
Before test
After test
173
l ORD311
n LIFE EXPECTANCY DATA: ORD311
Load conditions
Voltage: 5VDC
Current: 100mA 10mA , 20mA
Load: Resistive load
Cumulative failure rate
(%)
99.9
No failure
90
70
50
30
20mA
10mA
100mA
10
5
1
0.1
0
2 3
5 7 106
2 3
5 7 107
2 3
5 7 108
2 3
5 7 109
Number of operations
* Arrow indicates number of operations where test was completed.
Load conditions
Voltage: 12 VDC
Current: 5mA, 10mA, 100mA
Load: Resistive load
Cumulative failure rate
(%)
99.9
No failure
90
70
50
30
100mA
10mA
5mA
10
5
1
0.1
0
2 3
5 7 106
2 3
5 7 107
2 3
5 7 108
2 3
5 7 109
Number of operations
* Arrow indicates number of operations where test was completed.
Load conditions
Voltage: 24 VDC
Current: 1mA, 10mA, 100mA
Load: Resistive load
Cumulative failure rate 200mA 100mA
(%)
99.9
No failure
100mA 10mA 1mA
90
70
50
30
10
5
1
0.1
0
2 3
5 7 105
2 3
5 7 106
2 3
5 7 107
2 3
5 7 108
Number of operations
* Arrow indicates number of operations where test was completed.
174