MEDER ORD9216

J2R0015-41-31
REED SWITCH
ORD9216
General Purpose Miniature
n GENERAL DESCRIPTION
The ORD9216 is a small single-contact reed switch designed for general control of mediumlevel loads less than 100 V. The contacts are sealed within the glass tube with inert gas to maintain
contact reliability.
n FEATURES
(1) Reed contacts are hermetically sealed within a glass tube with inert gas and do not receive
any influence from the external atmospheric environment.
(2) Quick response
(3) The structure comprises the operating parts and electrical circuits arranged coaxially. Reed
switches are suited to applications in radio frequency operation.
(4) Reed switches are compact and light weight.
(5) Superior corrosion resistance and wear resistance of the contacts assures stable switching
operation and long life.
(6) With a permanent magnet installed, reed switches economically and easily become
proximity switches.
n EXTERNAL DIMENSIONS (Unit: mm)
f0.5
MAX f2.2
MAX 14.0
44.3±0.5
n APPLICATIONS
l Control equipment
l Communication equipment
l Measurement equipment
l Household appliances
159
l ORD9216
n ELECTRICAL CHARACTERISTICS
Parameter
Rated value
Unit
10∼50
AT
Pull-in Value (PI)
5min
AT
Contact resistance (CR)
100max
mW
Breakdown voltage
150min
V
VDC
Insulation resistance
109min
W
Electrostatic capacitance
0.3max
pF
Drop-out Value (DO)
10
VA
Maximum switching voltage
DC
100( )
AC
V
Maximum switching current
0.5
A
Maximum carry current
1.0
A
Contact rating
(1) Drop-out Value vs. Pull-in Value
(2) Contact resistance
(Measurement length: 32mm)
99.9
Cumulative frequency percent (%)
Drop-out Value
AT
50
40
30
20
10
0
95
90
80
70
60
50
40
30
20
10
5
1
0.1
10
20
30
Pull-in Value
160
99
40
50
AT
40
60
80
Contact resistance
100
mW
ORD9216 l
(3) Breakdown voltage
(4) Insulation resistance
(DC 100V)
Cumulative frequency percent (%)
99.9
Breakdown voltage
DC:V
400
300
200
100
0
10
20
30
40
50
Pull-in Value
AT
99
95
90
80
70
60
50
40
30
20
10
5
1
0.1
10
10
11
10
12
10
13
10
14
10
Insulation resistance
(5) Electrostatic capacitance
(1MHz)
Electrostatic capacitance
pF
0.4
0.3
0.2
0.1
0
10
20
30
40
50
AT
Pull-in Value
161
l ORD9216
n OPERATING CHARACTERISTICS
Rated value
Unit
Operate time
0.4max
ms
Bounce time
0.3max
ms
Release time
0.05max
ms
5000±400
Hz
500
Hz
Parameter
Resonant frequency
Maximum operating frequency
(1) Operate time
(2) Bounce time
(25Hz: 100AT energized)
(25Hz: 100AT energized)
99.9
ms
0.5
Cumulative frequency percent
99
Operate time
0.4
0.3
0.2
0.1
95
90
80
70
60
50
40
30
20
10
5
1
0
10
20
30
40
50
0.1
0
AT
0.1
Pull-in Value
0.2
0.3
0.4
ms
Bounce time
(3) Release time
(4) Resonant frequency
Release time
(25Hz: 100AT energized)
ms
15
10
5
0
99
95
90
80
70
60
50
40
30
20
10
5
1
0.1
10
20
30
40
Drop-out Value
162
Cumulative frequency percent (%)
99.9
50
AT
3400
3700
4000
Resonant frequency
Hz
ORD9216 l
n MECHANICAL CHARACTERISTICS
(1) Lead tensile test (static load)
(2) Lead tensile strength
(2.27kg-10sec)
99.9
Cumulative frequency percent (%)
Pull-in Value • Drop-out Value
AT
60
50
40
30
PI
20
DO
10
99
95
90
80
70
60
50
40
30
20
10
5
1
0.1
0
2
4
Contact resistance
6
8
10kg
Breaking load
0
80
60
CR
40
Before test
After test
n ENVIRONMENTAL CHARACTERISTICS
(1) Temperature characteristics
%
40
CR
Rate of change percent
30
20
DO
10
PI
0
−10
−20
−30
−40
−20
0
20
40
60
80
100
120
℃
Temperature
163
l ORD9216
(2) Temperature cycle
(3) Temperature and humidity cycle
-10℃∼+65℃
80%∼98%
(-55℃∼+125 ℃)
AT
60
Pull-in Value • Drop-out Value
Pull-in Value • Drop-out Value
AT
60
50
40
30
PI
20
DO
40
30
20
DO
0
0
mW
100
mW
100
80
PI
10
Contact resistance
Contact resistance
10
50
CR
60
Before test
80
CR
60
After test
Before test
(4) High temperature storage test
(5) Low temperature storage test
(-40℃-500H)
(+125℃-500H)
AT
60
Pull-in Value • Drop-out Value
Pull-in Value • Drop-out Value
AT
60
50
40
30
PI
20
50
40
30
PI
20
DO
DO
10
0
0
mW
100
mW
100
CR
60
Before test
164
Contact resistance
Contact resistance
10
80
After test
After test
80
CR
60
Before test
After test
ORD9216 l
(6) Shock test
1) Electrical characteristics
2) Misoperation area
(open→close)
(30G: 11ms)
G
1500
50
40
30
Acceleration
Pull-in Value • Drop-out Value
AT
60
PI
20
1000
Misoperation
area
DO
10
500
Contact resistance
0
mW
100
80
CR
0
10
20
30
40
50
60
AT
Pull-in Value
60
Before test
After test
(7) Vibration test
(20G: 10∼1000Hz)
Pull-in Value • Drop-out Value
AT
60
50
40
30
PI
20
DO
10
Contact resistance
0
mW
100
80
CR
60
Before test
After test
165
l ORD9216
n LIFE EXPECTANCY DATA: ORD9216
(%)
99.9
Current: 100mA 1mA , 5mA
Load: Resistive load
90
70
50
30
Cumulative failure rate
Load conditions
Voltage: 5VDC
No failure
5mA
1mA
100mA
10
5
1
0.1
0
2 3
5 7 105
2 3
5 7 106
2 3
5 7 107
2 3
5 7 108
Number of operations
* Arrow indicates number of operations where test was completed.
(%)
99.9
Current: 5mA, 10mA, 100mA
Load: Resistive load
No failure
90
70
50
30
Cumulative failure rate
Load conditions
Voltage: 12 VDC
100mA
10mA
5mA
10
5
1
0.1
0
2 3
5 7 105
2 3
5 7 106
2 3
5 7 107
2 3
5 7 108
Number of operations
* Arrow indicates number of operations where test was completed.
Load conditions
Voltage: 24 VDC
Current: 100mA, 200mA, 400mA
Load: Resistive load
Cumulative failure rate 200mA 100mA
(%)
99.9
90
70
50
30
200mA
400mA
10
5
100mA
1
0.1
0
2 3
5 7
2 3
5 7
2 3
Number of operations
166
5 7
2 3
5 7