J2R0015-41-31 REED SWITCH ORD9216 General Purpose Miniature n GENERAL DESCRIPTION The ORD9216 is a small single-contact reed switch designed for general control of mediumlevel loads less than 100 V. The contacts are sealed within the glass tube with inert gas to maintain contact reliability. n FEATURES (1) Reed contacts are hermetically sealed within a glass tube with inert gas and do not receive any influence from the external atmospheric environment. (2) Quick response (3) The structure comprises the operating parts and electrical circuits arranged coaxially. Reed switches are suited to applications in radio frequency operation. (4) Reed switches are compact and light weight. (5) Superior corrosion resistance and wear resistance of the contacts assures stable switching operation and long life. (6) With a permanent magnet installed, reed switches economically and easily become proximity switches. n EXTERNAL DIMENSIONS (Unit: mm) f0.5 MAX f2.2 MAX 14.0 44.3±0.5 n APPLICATIONS l Control equipment l Communication equipment l Measurement equipment l Household appliances 159 l ORD9216 n ELECTRICAL CHARACTERISTICS Parameter Rated value Unit 10∼50 AT Pull-in Value (PI) 5min AT Contact resistance (CR) 100max mW Breakdown voltage 150min V VDC Insulation resistance 109min W Electrostatic capacitance 0.3max pF Drop-out Value (DO) 10 VA Maximum switching voltage DC 100( ) AC V Maximum switching current 0.5 A Maximum carry current 1.0 A Contact rating (1) Drop-out Value vs. Pull-in Value (2) Contact resistance (Measurement length: 32mm) 99.9 Cumulative frequency percent (%) Drop-out Value AT 50 40 30 20 10 0 95 90 80 70 60 50 40 30 20 10 5 1 0.1 10 20 30 Pull-in Value 160 99 40 50 AT 40 60 80 Contact resistance 100 mW ORD9216 l (3) Breakdown voltage (4) Insulation resistance (DC 100V) Cumulative frequency percent (%) 99.9 Breakdown voltage DC:V 400 300 200 100 0 10 20 30 40 50 Pull-in Value AT 99 95 90 80 70 60 50 40 30 20 10 5 1 0.1 10 10 11 10 12 10 13 10 14 10 Insulation resistance (5) Electrostatic capacitance (1MHz) Electrostatic capacitance pF 0.4 0.3 0.2 0.1 0 10 20 30 40 50 AT Pull-in Value 161 l ORD9216 n OPERATING CHARACTERISTICS Rated value Unit Operate time 0.4max ms Bounce time 0.3max ms Release time 0.05max ms 5000±400 Hz 500 Hz Parameter Resonant frequency Maximum operating frequency (1) Operate time (2) Bounce time (25Hz: 100AT energized) (25Hz: 100AT energized) 99.9 ms 0.5 Cumulative frequency percent 99 Operate time 0.4 0.3 0.2 0.1 95 90 80 70 60 50 40 30 20 10 5 1 0 10 20 30 40 50 0.1 0 AT 0.1 Pull-in Value 0.2 0.3 0.4 ms Bounce time (3) Release time (4) Resonant frequency Release time (25Hz: 100AT energized) ms 15 10 5 0 99 95 90 80 70 60 50 40 30 20 10 5 1 0.1 10 20 30 40 Drop-out Value 162 Cumulative frequency percent (%) 99.9 50 AT 3400 3700 4000 Resonant frequency Hz ORD9216 l n MECHANICAL CHARACTERISTICS (1) Lead tensile test (static load) (2) Lead tensile strength (2.27kg-10sec) 99.9 Cumulative frequency percent (%) Pull-in Value • Drop-out Value AT 60 50 40 30 PI 20 DO 10 99 95 90 80 70 60 50 40 30 20 10 5 1 0.1 0 2 4 Contact resistance 6 8 10kg Breaking load 0 80 60 CR 40 Before test After test n ENVIRONMENTAL CHARACTERISTICS (1) Temperature characteristics % 40 CR Rate of change percent 30 20 DO 10 PI 0 −10 −20 −30 −40 −20 0 20 40 60 80 100 120 ℃ Temperature 163 l ORD9216 (2) Temperature cycle (3) Temperature and humidity cycle -10℃∼+65℃ 80%∼98% (-55℃∼+125 ℃) AT 60 Pull-in Value • Drop-out Value Pull-in Value • Drop-out Value AT 60 50 40 30 PI 20 DO 40 30 20 DO 0 0 mW 100 mW 100 80 PI 10 Contact resistance Contact resistance 10 50 CR 60 Before test 80 CR 60 After test Before test (4) High temperature storage test (5) Low temperature storage test (-40℃-500H) (+125℃-500H) AT 60 Pull-in Value • Drop-out Value Pull-in Value • Drop-out Value AT 60 50 40 30 PI 20 50 40 30 PI 20 DO DO 10 0 0 mW 100 mW 100 CR 60 Before test 164 Contact resistance Contact resistance 10 80 After test After test 80 CR 60 Before test After test ORD9216 l (6) Shock test 1) Electrical characteristics 2) Misoperation area (open→close) (30G: 11ms) G 1500 50 40 30 Acceleration Pull-in Value • Drop-out Value AT 60 PI 20 1000 Misoperation area DO 10 500 Contact resistance 0 mW 100 80 CR 0 10 20 30 40 50 60 AT Pull-in Value 60 Before test After test (7) Vibration test (20G: 10∼1000Hz) Pull-in Value • Drop-out Value AT 60 50 40 30 PI 20 DO 10 Contact resistance 0 mW 100 80 CR 60 Before test After test 165 l ORD9216 n LIFE EXPECTANCY DATA: ORD9216 (%) 99.9 Current: 100mA 1mA , 5mA Load: Resistive load 90 70 50 30 Cumulative failure rate Load conditions Voltage: 5VDC No failure 5mA 1mA 100mA 10 5 1 0.1 0 2 3 5 7 105 2 3 5 7 106 2 3 5 7 107 2 3 5 7 108 Number of operations * Arrow indicates number of operations where test was completed. (%) 99.9 Current: 5mA, 10mA, 100mA Load: Resistive load No failure 90 70 50 30 Cumulative failure rate Load conditions Voltage: 12 VDC 100mA 10mA 5mA 10 5 1 0.1 0 2 3 5 7 105 2 3 5 7 106 2 3 5 7 107 2 3 5 7 108 Number of operations * Arrow indicates number of operations where test was completed. Load conditions Voltage: 24 VDC Current: 100mA, 200mA, 400mA Load: Resistive load Cumulative failure rate 200mA 100mA (%) 99.9 90 70 50 30 200mA 400mA 10 5 100mA 1 0.1 0 2 3 5 7 2 3 5 7 2 3 Number of operations 166 5 7 2 3 5 7