MERRIMAC IQF-27L-200B

I&Q NETWORKS
IQF-27L Series
20 to 200 MHz / In-Circuit Phase and Amplitude Adjustments / 10% Bandwidth / Hi-Rel Package
PRINCIPAL SPECIFICATIONS
Model
Number
IQF-27L-***B
LO Frequency
fo, MHz
20 - 200
†
GENERAL SPECIFICATIONS
Bandwidth
RF Input
10% of fo
For complete Model Number replace *** with desired LO Frequency in MHz.
General Notes:
1. I & Q networks are integrated devices that produce two
quadrature-phased, equal amplitude signals when fed RF and LO
signals.
2. The IQF-27L series features in-circuit, voltage controlled phase and
amplitude balance adjustments that allow fine adjustments when the
device is in its normal operating environment. These features provides
accuracy not previously attainable in a comparably small package. In
addition, the voltage controlled phase and amplitude balance inputs
facilitate closed loop, servo operation using the adjustment inputs in the
feedback loops.
3. Merrimac I & Q networks comply with the relevant sections of
MIL-M-28837 and may be supplied screened for compliance with
additional specifications for military and space applications requiring the
highest reliability.
†
RF and LO Input Characteristics
Impedance:
50 Ω nom.
VSWR:
1.5:1 max.
RF Power Level:
0 dBm nom.
LO Power Level
+10 dBm nom.
I & Q Output Characteristics
Video Bandwidth:
DC to †50 MHz nom.
Output Impedance: 50 Ω nom.
Conversion Loss
(RF to I or Q):
10 dB typ.,12 dB max.
IF Balance (I to Q) @ Vc = +5V
Phase:
90° ± 2°
Amplitude:
0 ± 0.2 dB
Bias Controls, @ fo: 0 to +10V
Phase Tuning:
±5° nom.
Amplitude Range: ±1 dB nom.
Temperature Stability: ±0.2 dB, ±1° max.
Operating Temp:
-- 55° to +85°C
Weight, nominal:
0.55 oz (15.4 g)
RF and Video Bandwidths are typically much greater than specified.
L - Package Outline
NOTES:
1. Tolerance on 3 place decimals
±.010(.25) except as noted.
2. Dimensions in inches over millimeters.
3. Dimensions marked with * apply only at body.
4. All unmarked pins are case ground.
Phase Adjust
LO Input
I Output
Amplitude Adjust
RF Input
Q Output
29Apr96