MICRONETICS ANG-BBV-C

-
ANG-BBV SERIES
AUTOMATED NOISE GENERATORS FOR BASEBAND VIDEO TESTING
DESCRIPTION:
Micronetics ANG-BBV Series of Noise
Generators are specifically designed for
* Color LCD Screen
testing baseband (NTSC, PAL, SDTV,
HDTV) video and audio systems in the
* Intuitive GUI Interface
presence of noise. Ideal for signal quality
and picture quality testing on
* Flexible Architecture
encoder/decoder ICs.
S+N Combiner gives combined signal
and noise output
ANG-BBV SERIES O UTPUT C HARACTERISTICS
MODEL
FREQUENCY
FLATNESS
dB P-P
NOISE
DENSITY
ANG-BBV
20Hz - 80MHz
2.0 dB
-70 dBm/Hz
SIGNAL
GAIN
Accurate Gaussian Noise with high
peak factor for true to nature interference
simulation
0 dBm
Optional signal attenuator to set S/N ratios
USER CONTROLS:
Noise Power in D.U.T. Bandwidth
Proprietary amplifier technology, faithfully passes baseband audio, baseband
video and IF signals with 0dB loss.
Noise Power in Spectral Density (dBm/Hz)
D.U.T. Bandwidth Entry
Center Frequency Entry
SPECIFICATIONS:
Noise Attenuation Control
Operating Temp: 0 to +70 οC
Noise On-Off, Increment, Decrement, Step Size Adjust
Supply Voltage: 90-240v, 50/60 Hz
Auto Sensing
Temp Stability:
0.025 dB/ οC
Output Impedance: 75 ohm,
Crest Factor:
15 dB
Attenuation: 0 to 100dB, 1db steps
(optional 0.1 dB steps)
Save/Recall Registers: 31
Dimensions:
12” x 19” x 5.25”
Weight:
25 lbs. maximum
CE Compliant to ISM 1-A
MICRONETICS / 26 HAMPSHIRE DRIVE / HUDSON, NH 03051 / TEL: 603-883-2900 / FAX: 603-882-8987
WEB: WWW.MICRONETICS.COM
Flexible Architecture - ANG Series Standard Options Include:
How to order
Instrument
OPT001: 0.1 dB noise amplitude control resolution: This allows the user to
set the noise amplitude to within 0.1 dB. Standard is 1.0 dB
ANG-BBV - X
Model:
OPT002: Carrier Signal input and built in combiner for S+N output. This is
useful for interference tests that require adding noise to a carrier signal.
OPT002A: This is similar to OPT002, but utilizes a resistive combiner in
order to preserve the low baseband frequency specification of those models
which have a low frequency specification of 100 Hz. This combiner has more
insertion loss than that of OPT002, so if frequencies below 10 MHz are not
required, then OPT002 makes more sense.
OPT003: Signal Path Attenuator. This option allows the user to control the
amplitude of the carrier signal. The range and resolution is 0 - 127 dB in
1.0 dB Steps.
Connector Type:
A=N (female)
B=BNC (female)
C=SMA (female)
Options
ANG-BBV-X - OPTXXX
Model:
Options: (reference option chart)
OPT003A: This option is as OPT003 but the step size is 0.1 dB instead of 1.0 dB
OPT003B: This option is similar to OPT003 but the signal amplitude is "make before break" meaning the carrier signal is perpetually
transmitted through the attenuators even in the short transition from one attenuation state to the next. This allows the user to change
the amplitude in the signal path without losing lock; especially useful in modem loop back testing where a break in the IF connection
from the modulator to the demodulator requires the entire test to be reset.
OPT003C: Similar to OPT003B except step size is 0.1 dB.
OPT005: 50 Ohm Impedance instead of 75 Ohm. Typical loss is 1 to 2dB from base model
OPT005A: Switchable Impedance 50 Ohm / 75 Ohm
OPT005B: 50 ohm Impedance using internal resistive impedance matching pad for low frequency models to preserve the low end frequency limit of 100 Hz. Loss is 6.0 dB from base model.
OPT005C: Switchable Impedance 75 Ohm / 50 Ohm using resistance matching pad for 50 Ohm setting.
OPT006: RS/232 Interface This option allows the ANG to be operated remotely using an RS/232 serial connection in addition to the
GPIB bus.
OPT007: Automatic C/N, Eb/No, C/No ratio mode: This option sets up a user specified Signal:Noise ratio automatically. The user connects a signal to the S input port of the ANG. The user needs to externally measure the signal power referenced to the S input port of
the ANG. The user then enters the signal power and the desired signal to noise ratio, and the ANG automatically sets it up calibrated
accurately to the S+N output port.
OPT007A: Similar to OPT007 but with the added feature that a power sensor for measuring the signal power can be connected directly
to the PM port of the ANG unit. The user simply enters the power reading from the external power meter into the ANG along with the
desired signal:noise ratio. The ANG automatically sets this ratio up accurately calibrated to the S+N output port. A directional coupler is
employed to send coupled power from the signal input path to the PM port. This allows the signal power to be perpetually monitored
without a break in the signal path with only small loss in the test signal through path. As with OPT007, this option can be combined with
the noise and signal attenuator options OPT001 and OPT002/A for greater ratio range/resolution.
OPT007A1: This option is similar to OPT007A except it enables the ANG to remotely control the power meter via RS/232 port. With
this option, the ANG automatically polls the power meter for signal power and uses the data to set up and maintain the user specified
S/N ratio. Because the power readings perpetually available, useful features such as "Ratio Track" and "Signal Track" are available.
The power meter must utilize SCPI commands. Not all power meter make/models are supported. Contact factory for details.
MICRONETICS / HUDSON, NH 03051 / TEL: 603-883-2900 / FAX: 603-882-8987 / EMAIL: TESTSALES@MICRONETICS>COM
WEB: WWW.MICRONETICS.COM