MORNSUN A2415XT-W2

A_(X)T-W2 Series
0.25W,FIXED INPUT, ISOLATED & UNREGULATED
DUAL OUTPUT, SMD DC-DC CONVERTER
multi-country patent protection RoHS
FEATURES
PRODUCT PROGRAM
Small footprint
SMD Package Style
No Heat sink Required
1KVDC Isolation
Temperature Range: -40°C to +85°C
Internal SMD construction
No External Component Required
Industry Standard Pinout
RoHS Compliance
Input
Part
Number
Output
Voltage (VDC)
Nominal
Range
Voltage
(VDC)
Current (mA)
Max
Efficiency
(%, Typ.)
Min
A0503(X)T-W2
±3.3
±38
±4
62
A0505(X)T-W2
±5
±25
±3
64
±9
±14
±2
65
A0512(X)T-W2
±12
±11
±2
67
A0515(X)T-W2
±15
±9
±1
66
A1205(X)T-W2
±5
±25
±3
65
5
A0509(X)T-W2
4.5-5.5
±9
±14
±2
64
A1212(X)T-W2
±12
±11
±2
63
The A_(X)T-W2 Series are specially designed
A1215(X)T-W2
±15
±9
±1
64
for applications where a group of polar power
A2405(X)T-W2
±5
±25
±3
61
supplies are isolated from the input power supply
A2409(X)T-W2
±9
±14
±2
62
in a distributed power supply system on a circuit
A2412(X)T-W2
±12
±11
±2
63
A2415(X)T-W2
±15
±9
±1
65
A1209(X)T-W2
APPLICATIONS
board.
These products apply to:
1) Where the voltage of the input power supply is
12
24
10.8-13.2
21.6-26.4
Note: The A_XT-W2 series have no 3,6,8,9 pin. For example A0505XT-W2.
fixed (voltage variation ≤ ±10%);
2) Where isolation is necessary between input
and output (isolation voltage ≤1000VDC);
3) Where the regulation of the output voltage and
the output ripple noise are not demanding.
Such as: purely digital circuits, ordinary low
ISOLATION SPECIFICATIONS
Item
Test Conditions
Isolation voltage
Tested for 1 minute and 1mA max
1000
Min
Typ.
Max
Units
VDC
Isolation resistance
Test at 500VDC
1000
MΩ
frequency analog circuits, and IGBT power device
driving circuits.
OUTPUT SPECIFICATIONS
Item
MODEL SELECTION
A0505(X)T-W2
Line regulation
Rated Power
Package Style
Output Voltage
Input Voltage
Product Series
Test Conditions
Min
Load regulation
Address: 2th floor 6th building, Huangzhou Industrial
District, Guangzhou, China
Tel: 86-20-38601850
Fax:86-20-38601272
Http://www.mornsun-power.com
W
15
20
10% to 100% load (5V output)
12.8
15
10% to 100% load (9V output)
8.3
15
10% to 100% load (12V output)
6.8
15
10% to 100% load (15V output)
6.3
15
%
See tolerance envelope graph
Temperature drift
100% full load
Output ripple &Noise*
20MHz Bandwidth
50
Full load, nominal input(24V input)
500
Full load, nominal input (others input)
110
Switching frequency
Units
±1.2
For Vin change of 1%(Others output)
10% to 100% load (3.3V output)
Max
0.25
±1.5
For Vin change of 1%(3.3V output)
Output voltage accuracy
MORNSUN Science & Technology co.,Ltd.
Typ.
Output power
0.03
%/°C
100
mVp-p
KHz
*Test ripple and noise by “parallel cable” method. See detailed operation instructions at Testing of Power
Converter section, application notes.
The copyright and authority for the interpretation of the products are reserved by Mornsun
Specifications subject to change without notice.
A_(X)T-W2
A/1-2008
Page 1 of 2
APPLICATION NOTE
COMMON SPECIFICATION
Item
Test Conditions
Min
Typ.
Max
Units
95
%
Storage humidity
Operating temperature
-40
85
Storage temperature
-55
125
Temp. rise at full load
15
Lead temperature
and reliably, During operation, the minimum output
°C
25
1.5mm from case for 10 seconds
this product should never be operated under
please connect a resistor with proper resistance at
Free air convection
Case material
load is not less than 10% of the full load, and that
no load! If the actual output power is very sm all,
260
Cooling
Requirement on output load
To ensure this module can operate efficiently
the output end in parallel to increase the load.
Plastic(UL94-V0)
Short circuit protection*
1
MTBF
3500
Weight
s
Recommended circuit
If you want to further decrease the input/output
K hours
ripple, an “LC” filtering network may be connected
g
to the input and output ends of the DC/DC
1.70
converter, see (Figure 1).
*Supply voltage must be discontinued at the end of short circuit duration.
L
L
+Vo
Vin
TYPICAL CHARACTERISTICS
C
DC DC
C
L
GND
C
0V
-Vo
(Figure 1)
It should also be noted that the inductance and
the frequency of the “LC” filtering network should
be staggered with the DC/DC frequency to avoid
mutual interference. However, the capacitance of
the output filter capacitor must be proper. If the
capacitance is too big, a startup problem might
Operating Temp.(oC)
Temperature ( o C)
Output Voltage Regulation and Over-voltage
Protection Circuit
The simplest device for output voltage
260 o C
250
1 0 S ec M ax
o
22 0 C
200
regulation,
150
100
Vin
Time ( s ec . )
6.50
(0.250)
6.25
(0.240)
4.25
(0.167)
A_T-W2
10 9 8 7 6
6 .76
(0.26 6)
A
1.85
(0.07 3)
7 .15
(0.28 0)
0.25
(0.010)
0 .50 (0.02 0)
1.35
(0 .0 53)
1 2 3 4 5
5 .00
。
GND
1 2
RE G
+Vo
RE G
-Vo
0V
DC DC
(Figure2)
A_XT-W2
10
-Vo
Vin
7
Overload Protection
Under normal operating conditions, the output
4 5
circuit of these products has no protection against
1.2
(0.047)
7.50
( 0.295)
11.20
(0.441)
1.8
0V
DC
GND
First Angle Projection
0.25
(0 .010)
+Vo
RE G
DC
REC OMME NDE D FOO TP RINT
To p view,gr id :2.5 4m m(0 .1 inch)
0.60 0.05
(0 .0 24 0.00 2)
over-current
or output end in series (Figure2).
OUTLINE DIMENSIONS & FOOTPRINT DETAILS
2 .54 0.10
(0.1 00 0.004 )
and
overheat protection that is connected to the input
50
15 .24 (0.600)
10.1 6
(0 .400)
over-voltage
protection is a linear voltage regulator with
90 Sec Max
(>220 o C )
0
2.54
(0.100)
arise. It’s not recommended to connect any
external capacitor in the application field.
RECOMMENDED REFLOW SOLDERING PROFILE
FOO TPRINT DE TAIL S
P in
Functio n(T) Fun ction (X T)
1
GND
G ND
2
Vin
Vin
4
0V
0V
5
-Vo
-Vo
7
+Vo
+ Vo
10
NC
NC
3, 6, 8, 9
NC
NO P IN
NC:No Con nection
Note :
Unit:mm (inch)
P in section:0.60 *0 .2 5m m(0 .024*0 .010 inch)
P in section tolerances: 0.10mm( 0 .004inch)
G eneral tole ran ces: 0.1 5m m( 0.00 6in ch)
The copyright and authority for the interpretation of the products are reserved by Mornsun
over-current
and short-circuits.
The simplest
method is to connect a self-recovery fuse in series
at the input end or add a circuit breaker to the
circuit.
No parallel connection or plug and play.
Note:
1. All specifications measured at Ta=25°C, humidity<75%,
nominal input voltage and rated output load unless
otherwise specified.
2. Only typical models listed, specifications of custom
product may be different. Please contact our service
people directly for certain conditions.
3. Operation under minimum load will not damage the
converter; However, they may not meet all specification
listed.
Specifications subject to change without notice.
A_(X)T-W2
A/1-2008
Page 2 of 2