MORNSUN WRA4812ZP-3W

WRA_ZP-3W & WRB_ZP-3W Series
3W, WIDE INPUT, ISOLATED & REGULATED
DUAL/SINGLE OUTPUT, DIP DC-DC CONVERTER
multi-country patent protection RoHS
FEATURES
PRODUCT PROGRAM
Wide (2:1) Input Range
Operating Temperature:-40 to +85°C
Short circuit protection(automatic recovery)
1500VDC Isolation
Internal SMD construction
Metal Shielding Package
No Heat Sink Required
Industry Standard Pinout
MTBF>1,000,000 hours
RoHS Compliance
APPLICATIONS
Input
Part
Number
Output
Voltage (VDC)
Effiecincy
(%, Typ)
Current (mA)
Voltage
(VDC)
Max
Min
WRA0505ZP-3W
±5
±300
±30
68
WRA0509ZP-3W
±9
±166
±16
70
WRA0512ZP-3W
±12
±125
±12
71
WRA0515ZP-3W
±15
±100
±10
71
3.3
600
60
65
WRB0505ZP-3W
5
600
60
68
WRB0512ZP-3W
12
250
25
71
WRB0515ZP-3W
15
200
20
71
WRA1205ZP-3W
±5
±300
±30
76
WRA1209ZP-3W
±9
±166
±16
78
WRA1212ZP-3W
±12
±125
±12
79
±15
±100
±10
80
3.3
600
60
71
Nominal Range
WRB0503ZP-2W
5
4.5-9
Max*
11
The WRB_ZP-3W &WRA_ZP-3W Series are
WRA1215ZP-3W
specially designed for applications where a wide
WRB1203ZP-2W
range input voltage power supplies are isolated
WRB1205ZP-3W
5
600
60
76
from the input power supply in a distributed
WRB1212ZP-3W
12
250
25
79
power supply system on a circuit board. These
WRB1215ZP-3W
15
200
20
80
products apply to:
WRA2405ZP-3W
±5
±300
±30
78
1) Where the voltage of the input power supply
WRA2409ZP-3W
±9
±166
±16
79
WRA2412ZP-3W
±12
±125
±12
80
WRA2415ZP-3W
±15
±100
±10
81
3.3
909
90
76
WRB2405ZP-3W
5
600
60
78
WRB2412ZP-3W
12
250
25
81
WRB2415ZP-3W
15
200
20
82
WRA4805ZP-3W
±5
±300
±30
78
WRA4809ZP-3W
±9
±166
±16
79
WRA4812ZP-3W
±12
±125
±12
80
±15
±100
±10
81
3.3
909
90
76
WRB4805ZP-3W
5
600
60
78
WRB4812ZP-3W
12
250
25
80
WRB4815ZP-3W
15
200
20
81
is wide range (voltage range≤ 2:1);
2) Where isolation is necessary between input
and output(isolation voltage≤1500VDC);
3) Where the regulation of the output voltage
and the output ripple noise are demanded.
MODEL SELECTION
WRB0512ZP-3W
WRB2403ZP-3W
WRA4815ZP-3W
Ra ted Power
Packag e Style
Output Voltage
Input Voltage
Produ ct S eries
WRB4803ZP-3W
12
24
48
9-18
18-36
36-72
22
40
80
*Input voltage can’t exceed this value, or will cause the permanent damage.
Note: The load shouldn't be less than 10%, otherwise ripple will increase dramatically.
Operation under 10% load will not damage the converter; However, they may not meet all specification
listed.
ISOLATION SPECIFICATIONS
MORNSUN Science & Technology co.,Ltd.
Address: 2th floor 6th building, Hangzhou
Industrial District, Guangzhou, China
Tel: 86-20-38601850
Fax: 86-20-38601272
http://www.mornsun-power.com
MORNSUN reserves the copyright
Item
Test conditions
Min
Isolation voltage
Tested for 1 minute and 1 mA max
1500
Isolation resistance
Test at 500VDC
1000
Isolation capacitance Input/Output
Specifications subject to change without notice.
WRA_ZP-3W & WRB_ZP-3W
Typ
Max
Units
VDC
MΩ
85
A/1-2008
pF
Page 1 of 2
OUTPUT SPECIFICATIONS
APPLICATION NOTE
*Dual output models unbalanced load: ±5%.
**Test ripple and noise by “parallel cable” method. See detailed operation instructions at Testing of
Power Converter section, application notes.
Requirement on output load
In order to ensure the product operate efficiently
and reliably, in addition to a max load (namely full
load), a minimum load is specified for this kind of
DC/DC converter. Make sure the specified range
of input voltage is not exceeded, the minimum
output load no less than 10% load. If the actual
load is less than the specified minimum load, the
output ripple may increase sharply while its
efficiency and reliability will reduce greatly. If the
actual output power is very small, please add an
appropriate resistor as extra loading, or contact
our company for other lower output power
products.
COMMON SPECIFICATIONS
Recommended Circuit
All the WRA_ZP-3W & WRB_ZP-3W Series
Item
Test conditions
Output power
See below products program
Positive voltage accuracy Refer to recommended circuit
Negative voltage accuracy Refer to recommended circuit
10% to 100% load(WRB_ZP_3W)
Load regulation
10% to 100% load(WRA_ZP_3W)*
Line regulation
Input voltage from low to high
Temperature drift
Refer to recommended circuit
Min
Typ
0.3
3
±1
±3
±3
±5
±0.5 ±0.75
±0.5
±0.2
20MHz bandwidth
50
Switching frequency
100% load, nominal input voltage
300
Test Conditions
Min
Typ
Storage humidity
Operating temperature
Storage temperature
-40
-55
Temp. rise at full load
Lead temperature
Units
W
%
±1
±0.5
±0.03 %/°C
Ripple & Noise**
Item
Max
100 mVp-p
KHz
Max
Units
95
%
85
125
°C
have been tested according to the following
recommended testing circuit before leaving factory
(Figure 1). This series should be tested under
load.
15
1.5mm from case for 10 seconds
No-load power consumption
0.2
Cooling
Short circuit protection
Copper, Nickel Coated
1000
Weight
Cin
W
DC
K hours
g
Note:
1.All specifications measured at TA=25°C, humidity<75%, nominal input voltage and rated output load
unless otherwise specified.
2.See below recommended circuits for more details.
0V
-Vout
Single Output
Vin
Cin
15
DC
GND
Free air convection
Continuous, automatic recovery
Case material
MTBF
+Vout
Vin
300
+Vout
DC
DC
0V
GND
(Figure 1)
If you want to further decrease the input/output
ripple, you can increase capacitance properly or
choose capacitors with low ESR. However, the
TYPICAL CHARACTERISTICS
capacitance of the output filter capacitor must be
proper. If the capacitance is too big, a startup
problem might arise. For every channel of output,
provided the safe and reliable operation is
ensured, the greatest capacitance of its filter
100
Operating Temp.( C )
OUTLINE DIMENSIONS& PIN CONNECTIONS
(0.094)
First Angle Projection
(0.600)
20.00 (0.787)
32.00(1.260)
11
2 3
RECOMMENDED FOOTPRINT
Top view,grid:2.54mm(0.1inch),
di amete r:1.0 0mm(0 .039 inch)
Dual Output
23 22
16
14
( Bottom View )
23 22
16
14
2 3
9
capacitor sees (Table 1). General:
Cin: 5V&12V
100μF
24V&48V
10μF-47μF
Cout: 10μF/100mA
Output External Capacitor Table(Table 1)
Single Vout
Cout
Dual Vout
Cout
(VDC)
(uF)
(VDC)
(uF)
3.3
2200
±5
680
5
1000
±9
470
12
470
±12
330
15
330
±15
220
11
Input Current
When it is used in unregulated power supply, be
sure that the fluctuating range of the power supply
2.54
(0.100)
4.57
(0.180)
22.86 (0.900)
Single Output
23 22
and the rippled voltage do not exceed the module
16
14
standard. Input current of power supply should
Note:
Unit:mm(inch)
Pin diameter:0.50mm(0.020inch)
Pin tolera nces:±0.10mm(±0.004inch)
Gen eral tolerances:± 0.2 5mm(± 0.010inch)
MORNSUN reserves the copyright
2 3
11
FOOTPRINT DETAILS
Pin
2,3
9
11
14
16
22,23
Single
GND
No Pin
NC
+Vo
0V
Vi n
Dual
GND
0V
-Vo
+Vo
0V
Vin
NC:No Connection
Specifications subject to change without notice.
module (See figure 2), General: Ip ≤1.4*Iin-max
Input Current(A)
0.50
(0.020)
4.10
(0.161)
( Side View )
10.00
(0.394)
afford the startup current of this kind of DC/DC
Ip
Input Voltage
Range
Input Voltage (V)
No parallel connection or plug and play.
WRA_ZP-3W & WRB_ZP-3W
A/1-2008