MORNSUN PWB4809LT-1W5

PWA_LT-1W5 & PWB_LT-1W5 Series
1.5W, WIDE INPUT ISOLATED & REGULATED
SINGLE/DUAL OUTPUT DC/DC CONVERTER
MINIATURE SMD PACKAGE
multi-country patent protection RoHS
FEATURES
PRODUCT PROGRAM
Wide (4:1) Input Range
Short Circuit Protection(automatic recovery)
1500VDC Isolation
Operating Temperature: -40°C to +85°C
No Heat Sink Required
No external component required
MTBF>1,000,000 hours
RoHS Compliance
Input
Part
Number
Output
Voltage (VDC)
Efficiency
(%, Typ)
Current (mA)
Voltage
(VDC)
Max
Min
PWA2405LT-1W5
±5
±150
±15
74
PWA2412LT-1W5*
±12
±63
±6
78
PWA2415LT-1W5*
±15
±50
±5
80
PWB2403LT-1W5*
3.3
455
45
72
PWB2405LT-1W5*
5
300
30
76
PWB2409LT-1W5*
9
167
17
78
PWB2412LT-1W5*
PWB2415LT-1W5*
12
15
125
100
12
10
79
80
Nominal
24
Range
Max**
9.0-36
40
PWA4805LT-1W5*
±5
±150
±15
74
The PWA_LT-1W5 & PWB_LT-1W5 Series are
PWA4812LT-1W5*
±12
±63
±6
76
specially designed for applications where a wide
PWA4815LT-1W5*
±15
±50
±5
78
range input voltage power supplies are isolated
PWB4803LT-1W5*
3.3
455
45
72
from the input power supply in a distributed
PWB4805LT-1W5*
5
300
30
76
power supply system on a circuit board.
PWB4809LT-1W5*
9
167
17
78
These products apply to:
PWB4812LT-1W5*
12
125
12
79
1) Where the voltage of the input power supply is
PWB4815LT-1W5*
15
100
10
80
APPLICATIONS
wide range(voltage range≤4:1);
2) Where isolation is necessary between input
and output (Isolation Voltage ≤1500 VDC);
48
18-72
80
*Designing.
**Input voltage can’t exceed this value, or will cause the permanent damage.
Note: The load shouldn't be less than 10%, otherwise ripple will increase dramatically.
Operation under 10% load will not damage the converter; However, they may not meet all specification listed.
3) Where the regulation of the output voltage
and the output ripple noise are demanded.
MODEL SELECTION
PWA2405LT-1W5
Rated Power
Package Style
Output Voltage
Input Voltage
Product Series
MORNSUN Science & Technology co.,Ltd.
Address: 2th floor 6th building, Huangzhou
Industrial District, Guangzhou, China
Tel: 86-20-38601850
Fax: 86-20-38601272
Http://www.mornsun-power.com
MORNSUN reserves the copyright
ISOLATION SPECIFICATIONS
Item
Test Conditions
Min
Isolation voltage
Tested for 1 minute and 1mA max
1500
Isolation resistance
Test at 500VDC
1000
Isolation Capacitance
Input/Output
Typ
Max
Units
VDC
MΩ
85
pF
OUTPUT SPECIFICATIONS
Item
Test conditions
Min
Output Power
See above products program
0.15
Positive voltage accuracy Refer to recommended circuit
Typ
±1
Max
Units
1.5
W
±3
±3
±5
Load Regulation
From 10% to 100% load
±0.5
±1.5*
Line Regulation
Input voltage from low to high
±0.2
±0.75
Temperature Drift (Vout)
Refer to recommended circuit
Output ripple& Noise**
20MHz Bandwidth
35
Switching Frequency
100% load, nominal input voltage
300
Negative voltage accuracy Refer to recommended circuit
%
0.03
%/°C
75
mVp-p
KHz
*Dual output models unbalanced load: ±5%.
**Test ripple and noise by “parallel cable” method. See detailed operation instructions at Testing of Power
Converter section, application notes.
Note:
1. All specifications measured at TA=25°C, humidity<75%, nominal input voltage and rated output load unless
Otherwise specified.
2. See below recommended circuits for more details.
Specifications subject to change without notice.
PWA_LT_1W5 & PWB_LT_1W5
A/2-2008
Page 1 of 2
COMMON SPECIFICATIONS
Max
Units
Recommended Circuit
All the PWA_LT-1W5 & PWB_LT-1W5 Series
Storage humidity range
95
%
have been tested according to the following
Operating Temp. range
-40
85
-55
125
Item
Test conditions
Min
Storage Temp. range
Typ
Temp. rise at full load
Lead temperature
recommended testing circuit before leaving
°C
15
1.5mm from case for 10 seconds
factory. This series should be tested under load.
(see Figure 1).
245
Short circuit protection
Continuous, automatics recovery
Cooling
Case Material
Cin
Plastic(UL94-V0)
MTBF
1000
Weight
DC
DC
GND
K hours
g
5.2
+Vout
Vin
Free air convection
Single Output
Vin
+Vout
Cin
DC
DC
0V
GND
TYPICAL TEMPERATURE CUTVE
0V
-Vout
(Figure 1)
Temperature Derating Graph
If you want to further decrease the input/output
ripple, you can increase capacitance properly or
choose capacitors with low ESR. However, the
Safe Operating Area
capacitance of the output filter capacitor must be
proper. If the capacitance is too big, a startup
problem might arise. For every channel of output,
provided the safe and reliable operation is
ensured, the greatest capacitance of its filter
Operating Temp.( C )
capacitor sees (Table 1). General:
RECOMMENDED REFLOW SOLDERING PROFILE
Cin:
R e com m ended R e flo w Pro fil e
50 Sec M ax
( >22 0℃)
P eak.Te m p 235~ 2 45℃
250
Tem pe ra tu re (℃ )
100
50
0
Tim e (s ec.)
OUTLINE AND SOLDER PAD DIMENSIONS
8. 2
[ 0.3 2]
0 .50
[0 .020
7. 5 [ 0.3 ]
Input Current
When it is used in unregulated power supply,
15. 25[ 0.6 ]
Side Vie w
10μF-47μF
Output External Capacitor Table(Table 1)
Single Vout
Cout
Dual Vout
Cout
(VDC)
(uF)
(VDC)
(uF)
3.3
2200
±5
680
5
1000
±9
470
9
680
±12
330
12
470
±15
220
15
330
-
90 S ec M ax
( >1 90℃)
23. 86
[ 0. 94]
100μF
Cout: 10μF/100mA
200
150
12V
24V&48V
1.4
[0 .05 5]
0.15
be sure that the fluctuating range of the power
0. 15
supply and the rippled voltage do not exceed the
module standard. Input current of power supply
1 3.1
[ 0.5 2]
should afford the flash startup current of this kind
17 .78 [0. 7]
of DC/DC module (Figure 2)
0.5
[0 .02 ]
1.0 2
[0. 04]
13. 7
[0. 54]
3.04
[ 0.1 2]
7
15. 24
[ 0.6 0]
2. 0
[0. 08]
Top View
1
Pin
Sing le
D ual
1
GN D
GND
7
NC
NC
9
18. 5
[0.73 ]
10
16
0. 8
[ 0.0 3]
8
2.5 4
[0. 10]
15 .2
[0 .60 ]
2.5 4
[ 0. 10]
8
NC
0V
9
+Vo
+Vo
10
0V
-Vo
16
Vin
Vin
Input Current(A)
General: Ip ≤1.4*Iin-max:
Pin Con ne ctio ns
Ip
Input Voltage
Range
Input Voltage (V)
Note: Unit: mm[inch]; Tolerance: ±0.25mm; All Pins on a 2.54mm .
APPLICATION NOTE
Requirement On Output Load
In order to ensure the product operate efficiently and reliably, in addition to a max load
No parallel connection or plug and play.
(namely full load), a minimum load is specified for this kind of DC/DC converter. Make sure the
specified range of input voltage is not exceeded, the minimum output load no less than 10%
load. If the actual load is less than the specified minimum load, the output ripple may increase
sharply while its efficiency and reliability will reduce greatly. If the actual output power is very
small, please add an appropriate resistor as extra loading, or contact our company for other
lower output power products.
MORNSUN reserves the copyright
Specifications subject to change without notice.
PWA_LT_1W5 & PWB_LT_1W5