WIDE BAND ISOLATION TRANSFORMER R3600 SERIES • For RF, DS3/E3, Boradband, BPL and Ethernet Magnetics which require Supplementary or Reinforced Isolation • Construction complies with IEC60950 Isolation requirement • RoHS Compliant Product • Operating Temp : 0°C to 70°C (extended temperature subject to request) ELECTRICAL SPECIFICATION @ 25°C PART NO Turns Ratio Pri OCL (µH) Min Pri DCR (W) Max Insertion Loss Insertion Loss Insertion Loss dB Max dB Max dB Typ Hipot VRMS R3600- Pri : Sec ±5% 1-4 1-4 1MHz 100MHz 300MHz Pri to Sec 1 2 3 4 5 6 1:1 1CT:1CT 1:2 1:1:1 3:3:1 1:1.224 500 800 120 120 200 500 0.30 0.50 0.20 0.20 0.30 0.50 -0.5 -0.5 -0.8 -0.8 -0.5 -0.8 -1.0 -1.2 -1.0 -1.0 -1.0 -1.0 -2.6 -3.5 -1.5 -1.5 -3.0 -3.0 4500 3000 4500 4500 3000 3000 Schematic B A B C C B Note: • OCL measured @ 100KHz, 0.1VRMS at Pin 1-4 (with 2-3 shorted) • Insertion Loss measured with 100W as Input (Primary) Impedance between 1-4 and Output (Secondary) load with respective impedance • 50W and 75W impedance data available upon request Mechanical Schematic Schematic A Dimensions Unless otherwise specified, all tolerances are: inch: .XX : ± 0.015 .XXX : ±0.004 mm: X,X : ± 0,38 X,XX : ±0,10 Schematic B Schematic C Product performance is limited to specified parameter. Data is subject to change without prior notice. 2570 W. 237th Street, Suite B Torrance, CA 90505 Tel: (310) 325-1043 Fax: (310) 325-1044 R3600-XX 1004JW www.mpsind.com [email protected]