MRV EM316DMR3G-3R

Media Converters
Repeaters and Optimizers
Datasheet
FD
SFP Multi-Rate Dual Transponder
Features
Wide range of applications:
- Media conversion
- Signal repeating
- Lambda conversion
- WDM
- OADM
- Self-healing redundant links
- Physical layer multicasting
Any-port-to-any-port connectivity
Single-port-to-multiport connectivity
3R signal regeneration
- Retransmission
- Reshaping
- Retiming
Overview
The Fiber Driver® SFP Multi-Rate Dual Transponder (EM316DMR3G-3R)
from MRV Communications defines a new level of deployment flexibility
and inventory management. It combines software selectable data rates,
any-port-to-any-port connectivity, and the use of Small Form-factor
Pluggable (SFP) optical transceivers. It offers an extremely wide range
of optical infrastructure solutions including media conversion, signal
repeating, lambda conversion, Wave Division Multiplexing (WDM), and
Optical Add/Drop Multiplexing (OADM). The EM316DMR3G-3R can
create self-healing redundant links for mission critical applications or
support physical layer multicast broadcasts of any protocol within its
range.
SFP Multi-Rate Dual Transponder deployment is quick and easy. The
module resides in a Fiber Driver chassis. The selected SFP transceivers
are inserted, and the ports are set to the corresponding data rate.
Changing the connection type at a later time means simply replacing
the SFP transceivers and configuring the module for the new data rate.
SFP transceivers are easily reuseable at different locations for other
applications. Reuse maximizes the investment in optical equipment
and reduces the need for on-hand inventory. MRV Communications
provides a complete range of optical and copper plug-in interfaces for
the EM316DMR3G-3R and other Fiber Driver modules.
The Fiber Driver SFP Multi-Rate Dual Transponder performs full 3R signal
regeneration - retransmission, reshaping, and retiming - on each channel
at any selected data rate from 42 Mbps to 3.2 Gbps. This range covers
Fast and Gigabit Ethernet, FDDI, ESCON, SONET (OC-3, OC-12 and OC-48),
Fibre Channel (1 Gbps and 2 Gbps), Serial Digital Video Interface (SDI)
SMPTPE-259M (270Mbps), High-Definition Serial Digital Video Interface
(HD-SDI) SMTPE-292M (1.5Gbps) and DVB-ASI (270Mbps). Bypassing the
signal retiming function creates a protocol-transparent 2R connection
for more application options.
[email protected]
Data rate support from 42 Mbps to 3.2 Gbps
SFP transceivers for flexible configuration
High port density - four data ports on a single slot
SNMP management through MegaVision Pro® and a
Fiber Driver network management module
SFP Digital Diagnostics (SFF-8472)
Benefits
Flexible and scalable
- Add or change optics to adjust data or media rates
- Maintain single item inventory
Wide range of optical and copper interfaces
- Standard wavelengths (850 nm, 1310 nm, 1550nm)
- CWDM wavelengths
- DWDM (ITU-T G.694.1-2002)
- Ethernet, Fast Ethernet, and Gigabit Ethernet
Media Converters
Repeaters and Optimizers
The data rate may be set through one of the management
interfaces available with a Fiber Driver network
management module - SNMP, Telnet, SSH, or the local serial
port - or by jumpers located on the module itself. The data
rates available using the onboard jumpers without remote
management are Fast and Gigabit Ethernet, Fibre Channel
(1 Gbps and 2 Gbps), and SONET (OC-3).
to-any-port internal mapping. Port assignments may be
changed through management at any time, allowing data
routes to change as needed and enabling the module to
perform physical layer multicasting for any protocol. For
example, the device may be configured to retransmit
the data signal entering port 1 out from ports 2, 3, and 4
simultaneously.
The application of the SFP Multi-Rate Dual Transponder
varies with the type of SFPs employed. The module may be
used as a media converter to connect network segments of
different media types, or as a lambda converter to connect
network elements operating at different wavelengths.
For example, a multi-mode link operating at 850 nm may
connect to a single-mode link operating at 1550 nm by
using the required SFPs. With its 3R functionality, the
EM316DMR3G-3R long-haul optics also work perfectly as
a repeater in a link spanning hundreds of kilometers.
In mission critical installations that demand maximum
uptime, EM316DMR3G-3R modules can establish a selfhealing redundant link. In the event of link loss, the
module pair is configured to automatically switch from
the primary to the secondary data path. The switchover
occurs in microseconds without the reconvergence times
and data loss associated with slower solutions like OSPF or
Spanning Tree.
Together with an externally connected Mux/DeMux unit
such as the 4-channel or 8-channel Fiber Driver CWDM
Passive Mux/DeMux (EM316PAMULC41, EM316PAMULC42
or EM316PAMULC8), the SFP Multi-Rate Dual Transponder
becomes a part of an elaborate SFP-based WDM solution.
It may be used to create a static trunk WDM system, a
trunk switching WDM system, or a WDM repeater with or
without lambda conversion. Deployed along a WDM trunk
at customer service points using MRV Communications
passive OADM technology, the SFP Multi-Rate Dual
Transponder can create a sophisticated Add/Drop
topology.
The EM316DMR3G-3R is factory-configured to support
two independent data connections; ports 1 & 2 and ports
3 & 4 are paired for redundancy. It also supports any-port-
The Fiber Driver SFP Multi-Rate Dual Transponder is a hotswappable, single-slot module that is compatible with
any powered Fiber Driver chassis. The EM316DMR3G3R is SNMP manageable with a Fiber Driver network
management module in the same chassis. MegaVision
Pro®, the MRV network management system, uses SNMP
to provide full graphical administration for all Fiber Driver
and other addressable systems in the network.
The EM316DMR3G-3R supports the SFF-8472 standard
including digital diagnostics. Together with the network
manager it provides real-time access to information such
as transceiver details, transceiver temperature, TX/RX
optical power, and transceiver supply voltage.
Contact your MRV Communication sales representative
for additional information about the full line of MRV
Communications products or for pricing and availability.
DMR Application # 1: Point-to-Point Media Conversion with Redundant Link
%-$-2'2AND&IBER$RIVER.INA3LOT#HASSIS
-3WITCH2OUTER
0RIMARY
3ECONDARY
KM
3-
#OPPER
*Range determined by SFP transceivers used and quality of fiber plant
[email protected]
3WITCH2OUTER
Media Converters
Repeaters and Optimizers
DMR Application # 2: Point-to-Point Repeater with Redundant Link
3WITCH2OUTER
3ECONDARY
0RIMARY
KM
KM
3WITCH2OUTER
%-$-2'2AND&IBER$RIVER.INA3LOT#HASSIS
*Range determined by SFP transceivers used and quality of fiber plant
DMR Application Example #3: 8-Channel CWDM with OADM
,OS!NGELES
3ANTA-ONICA
3WITCH2OUTER
'B%
#
'&
3!.
#HANNEL7$-3YSTEM
,!8
%-$-2'2&IBER$RIVER.INA3LOT#HASSIS
%-$-2'2&IBER$RIVER.INA3LOT#HASSIS
,AYER-ULTICAST
6IDEO3TREAMING
/#
3$)
3$)
2EDUNDANT,INK
#HANNEL7$-3YSTEM
3$)
%-$-2'2
(OLLYWOOD
3WITCH2OUTER
[email protected]
Media Converters
Repeaters and Optimizers
Physical Specifications
Operating Temperature Range
00C to 600C (320F to 1400F)
Storage Temperature
-40°C to 70°C (-40°F to 158°F)
Relative Humidity
85% maximum, non-condensing
Physical Dimensions
25 mm x 75 mm x 175 mm deep (1” x 3” x 7” deep)
Weight
Approximately 213 g (7.5 oz)
Regulatory Compliance
FCC Part 15 (Class A); IC (Class A); EMC Directive: Emission (Class A) and Immunity; RoHS Directive;
China RoHS; WEEE Directive
Ordering Information
Model
Function
Protocol
Connectors
Wavelength (nm)
Budget (dB)
Range
EM316DMR3G-3R
4-port SFP multi-rate transponder
module with quad CDR
Any from 42 Mbps to
3.2 Gbps in 3R mode
SFP (x4)
SFP dependent
SFP dependent
SFP dependent
MRV has more than 50 offices throughout the world. Addresses, phone numbers, and fax numbers are listed at www.mrv.com.
Please e-mail us at [email protected] or call us for assistance.
MRV (West Coast USA)
20415 Nordhoff St.
Chatsworth, CA 91311
800-338-5316
818-773-0900
MRV (East Coast USA)
295 Foster St.
Littleton, MA 01460
800-338-5316
978-952-4700
MRV (International)
Business Park Moerfelden
Waldeckerstrasse 13
64546 Moerfelden-Walldorf
Germany
Tel. (49) 6105/2070
Fax. (49) 6105/207-100
All statements, technical information and recommendations related to the products herein are based upon information believed to be reliable or accurate. However, the accuracy or completeness
thereof is not guaranteed, and no responsibility is assumed for any inaccuracies. Please contact MRV Communications for more information. MRV Communications and the MRV Communications
logo are trademarks of MRV Communications, Inc. Other trademarks are the property of their respective holders.
MRV-FD-DMR-100407
1398020-001 Rev. A2
Copyright ©2007 MRV Communications, Inc. All Rights Reserved.