MURATA-PS C1U-W-1200-12-TC2C

C1U-W-1200-12-Tx Series
AC/DC Front End Power Supply
PRODUCT OVERVIEW
The C1U-W-1200 is a 1200 Watt universal AC input, power-factor-corrected (PFC) front-end power supply for general
applications. The main output is 12V and standby output of either 5V or 3.3V. Packaged in U low profile, it is designed
to deliver reliable bulk power to servers, workstations, storage systems or any 12V distributed power architecture
systems requiring high power density. The highly efficient electrical and thermal design with internal cooling fans supports reliable operation conditions. The C1U-W-1200 is designed to auto-recover from over-temperature faults.
FEATURES
SELECTION GUIDE
RoHS compliant
1200W (110/220Vac) Output power
Part Number
12V Main output,
3.3V or 5V standby output
Dimensions: 1.67” x 5.5” x 14.2”
C1U-W-1200-12-TA1C
C1U-W-1200-12-TC1C
C1U-W-1200-12-TA2C
C1U-W-1200-12-TC2C
9.2 Watts per cubic inch density
INPUT CHARACTERISTICS
N+1 redundancy capable,
Parameter
Active current sharing on main output
Over-voltage, over-current,
over-temperature protection
Internal cooling fans
Power Output
Universal Line
Main Output
Standby
Output
Airflow
1200W
1200W
1200W
1200W
12V
12V
12V
12V
5V
3.3V
5V
3.3V
Front to back
Front to back
Back to front
Back to front
Conditions
Min.
Input Voltage Operating Range
Input Frequency
Turn-on Input Voltage
Turn-off Input Voltage
Maximum Input Current
Inrush Current
Ramp up
Ramp down
90
47
78.5
70.5
Power Factor
Output load >90%
Output load >50%
Typ.
55
Max.
Units
264
63
86.5
78
15
90
Vac
Hz
Vac
Arms
Apk
95%
75%
OUTPUT VOLTAGE CHARACTERISTICS
Output
Voltage
12V
3.3Vsb
5Vsb
Parameter
Voltage Set Point Accuracy
Line and Load Regulation
Ripple Voltage & Noise1
Output Current
Load Capacitance
Voltage Set Point Accuracy
Line and Load Regulation
Ripple Voltage & Noise1
Operating Range
Load Capacitance
Voltage Set Point Accuracy
Line and Load Regulation
Ripple Voltage & Noise1
Operating Range
Load Capacitance
Conditions
Min.
Typ.
Max.
12.12
11.75
12.48
120
98.3
40000
20MHz Bandwidth
0
3.3
3.2
3.4
33
6
1530
0
5
4.85
0
5.15
50
4
1530
Units
Vdc
mV p-p
A
μF
Vdc
mV p-p
A
μF
Vdc
mV p-p
A
μF
1
Ripple and noise are measured with 0.1 uF of ceramic capacitance and 2 x 270 uF of OSCON capacitance on each
of the power supply outputs. The output noise requirements apply over a 0 Hz to 20 MHz bandwidth. A short coaxial
cable with 50ohm scope termination is used. See Ripple Test Setup diagram.
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
Technical enquiries email: [email protected], tel: +1 (866) 740 1232
C1U-W-1200-12-Tx.A04 Page 1 of 4
C1U-W-1200-12-Tx Series
AC/DC Front End Power Supply
OUTPUT CHARACTERISTICS
Parameter
Conditions
Remote Sense
Efficiency
Output Rise Monotonicity
120
220Vac
90.6
Overshoot less than 10% for all outputs, no voltage negative between 10% to 95% during ramp up
AC ramp up
1.5
PS_On activated
150
12V Ramp 1A/μs
±600
3.3Vsb Ramp 1A/μs
±165
5Vsb Ramp 1A/μs
±250
Start-up Time
Transient Response
Current sharing accuracy (up to 3 in parallel)
Min.
Typ.
Max.
At 100% load
Hold-up Time
±10
20
Units
mV
%
s
ms
mV
%
ms
GENERAL CHARACTERISTICS
Parameter
Conditions
Min.
Storage Temperature Range
Operating Temperature Range
Operating Humidity
Storage Humidity
Shock
Sinusoidal Vibration
Non-condensing
-40
0
10
5
MTBF
Acoustic
Safety Approvals
Input Fuse
Material Flammability
Non-condensing
Typ.
Max.
70
50
90
90
Units
°C
%
30G non operating
0.5G, 5 – 500 Hz
Calculated per Bellcore at Ta=30°C
200
Khrs
Demonstrated
200
Khrs
ISO 7779-1999
60
dB LpAm
c-CSA-us (CSA 60950-1-03/UL 60950-1, First Edition) TUV approval (Bauart) EN 60950-1:2001
Power Supply has internal 20A/250V fast blow fuse on the AC line input
UL 94V-0
Switching Frequency
90KHz for Boost PFC Converter
165KHz for Main Output Converter
200KHz for Standby Output Converter
Weight
2.6kg
PROTECTION CHARACTERISTICS
Output
Voltage
12V
3.3Vsb
5Vsb
Parameter
Conditions
Min.
Over-temperature
Over Voltage
Over Current
Over Voltage
Over Current
Over Voltage
Over Current
Auto-restart
Latching
Latching
Latching
Latching
Latching
Latching
55
13
107
3.57
6.5
5.6
5
Conditions
Min.
Typ.
Max.
Units
65
14
122
4.02
8
6
7
°C
V
A
V
A
V
A
Max.
Units
ISOLATION CHARACTERISTICS
Parameter
Insulation Safety Rating / Test Voltage
Isolation
Material Flammability
Grounding
www.murata-ps.com
Typ.
Input to Output - Reinforced
3000
Vrms
Input to Chassis - Basic
1500
Vrms
Output to Chassis
Output to Output
UL 94V-0
Main Output Return and Standby Output Return are connected internally. 100kΩ resistor parallel with 100nF
capacitor is connected between Return and power supply chassis. Main Output Return should be connected to
the System Chassis.
Technical enquiries email: [email protected], tel: +1 (866) 740 1232
C1U-W-1200-12-Tx.A04 Page 2 of 4
C1U-W-1200-12-Tx Series
AC/DC Front End Power Supply
CONTROL SIGNALS
Status
Conditions
Description
LED
Off
Flashing Yellow
Flashing Green
Green
No AC input to all PS
Power Supply Failure
Main Output Absent
Power Supply Good
EMISSIONS AND IMMUNITY
Characteristic
Description
Harmonics
Voltage Fluctuation and Flicker
Emission Conducted
Emission Radiated
IEC/EN 61000-3-2
IEC/EN 61000-3-3
FCC 47 CFR Parts 15/CISPR 22/EN55022
FCC 47 CFR Parts 15/CISPR 22/EN55022
ESD
IEC/EN 61000-4-2
Electromagnetic Field
Electrical Fast Transients/Burst
Surge
RF Conducted Immunity
Magnetic Immunity
Voltage dips, interruptions
IEC/EN 61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
IEC/EN 61000-4-6
IEC/EN 61000-4-8
IEC/EN 61000-4-11
Criteria
Class A, 6dB margin
Class A, 6dB margin
4kV contact discharge
8kV operational air discharge
15kV non-operational air discharge
1kV/2kV, Performance Criteria B
3 Vac, 80% AM, 1kHz, Performance Criteria A
3 A/m
RIPPLE TEST SETUP
0.1uF Ceramic
2x270uF OSCON
Power Supply
Load Box
AC Phase
AC Ground
BNC to BNC Shielded Cable
General Notes:
1. Load the outputs at specified minimum
output current.
2. Connect the probe as shown with the
input tip and ground as short as possible.
Oscilloscope
20MHz BW
3. Take all measurements
4. Repeat the measurements with the
outputs at specified maximum output
current.
www.murata-ps.com
Technical enquiries email: [email protected], tel: +1 (866) 740 1232
C1U-W-1200-12-Tx.A04 Page 3 of 4
C1U-W-1200-12-Tx Series
AC/DC Front End Power Supply
MECHANICAL DIMENSIONS
CONNECTORS
Signal 16 pin connector details, Type: Molex:
39-28-5164 Mating part Molex: 39-51-2164
5.500
(139.70)
Pin
AC Input
Terminal Block
15.197 REF
(386.00)
M4 Ground Stud
1.673
(42.50)
14.220
(361.20)
Signal Connector
Output Terminal
M5 Studs
5.000
(127.00)
M4 Mounting Thread
(4X)
4.803
(122.00)
4.847
(123.12)
Signal
1
AC_OK
2
P_GOOD
3
PS_ON
4
BLANK
5
I_SHARE
6
BLANK
7
SENSE+
8
SENSE9
V_SB
10
V_SB
11
V_SB
12
V_SB
13
GND
14
GND
15
GND
16
GND
2-Pole terminal Block for AC Line and Neutral
Stud on Chassis for earth
+
12V Main
Output GND
Dimensions: 1.67” x 5.5 ” x 14.2”
USA:
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
www.murata-ps.com email: [email protected] ISO 9001 REGISTERED
03/17/09
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2009 Murata Power Solutions, Inc.
www.murata-ps.com
Mansfield (MA), Tel: (508) 339-3000, email: [email protected]
Canada:
Toronto, Tel: (866) 740-1232, email: [email protected]
UK:
Milton Keynes, Tel: +44 (0)1908 615232, email: [email protected]
France:
Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: [email protected]
Germany:
München, Tel: +49 (0)89-544334-0, email: [email protected]
Japan:
Tokyo, Tel: 3-3779-1031, email: [email protected]
Osaka, Tel: 6-6354-2025, email: [email protected]
China:
Shanghai, Tel: +86 215 027 3678, email: [email protected]
Guangzhou, Tel: +86 208 221 8066, email: [email protected]
Singapore:
Parkway Centre, Tel: +65 6348 9096, email: [email protected]
Technical enquiries email: [email protected], tel: +1 (866) 740 1232
C1U-W-1200-12-Tx.A04 Page 4 of 4