MURATA-PS VKA50MS24C

VKA50xSC
50 Wat
Watt
tt Single Output
Outpuut Half Brick
Brrick DC/DC Converter
OBSOLETE
PRODUCT
Contact Factory for Replacement Model
RoHS
S Compliant
Compliaant
18-36 V & 33 - 75V Input Range
High Efficiency: 87% Typical at
5V
100MS Transient Response 50100% Load Step
420 kHz Fixed-Frequency
Operation
Remote Sense
The VKA50xSC Series DC/DC
converters present an economical and
practical solution for distributed power
system architectures which require
high power density and efficiency
while maintaining system modularity
and upgradeability. With the ability to
operate over a wide input voltage range
of 18 to 36 and 33 to 75 volts, these
modules are ideal for use in battery
backup applications common in todays’
telecommunication and electronic data
processing applications. The output is
fully isolated from the input, allowing
for a variety of polarity and grounding
configurations.
The VKA50xSC’s proprietary
control circuitry responds to 50-100%
load steps in 100MSeconds to within 1%
nominal Vout.
Opperation too +100oC
Operation
+
Baseplate
Temperature
Primary Remote On/Off, Choice of
Pos/Neg Logic
Adjustable Output Voltage
Continuout Short-Circuit Protection
Thermal Shutdown
Case Ground Pin
The patented fixed frequency
architecture combined with surface
mount technology results in a compact,
efficient and reliable solution to DC/
DC conversion requirements. Safety
per UL1950, EN 60950 and CSA 22.2
#234.
PRODUCT SELECTION CHART
MODEL
INPUT
VOLTAGE
VKA50LS03C
VKA50LS05C
VKA50LS12C
VKA50LS15C
VKA50LS24C
VKA50MS03C
VKA50MS05C
VKA50MS12C
VKA50MS15C
VKA50MS24C
24VDC
(18-36)
48VDC
(33-75)
VOUT
(VDC)
IOUT
(A)
3.3V
5.0V
12.0V
15.0V
24.0V
3.3V
5.0V
12.0V
15.0V
24.0V
10.0
10.0
4.2
3.3
2.1
10.0
10.0
4.2
3.3
2.1
EFFICIENCY
MIN
80
85
87
88
89
81
86
88
89
89
TYP
81
86
88
89
90
82
87
89
90
90
THROUGH-HOLE SOLDERING INFORMATION
These devices are intended for wave soldering or manual soldering.
They are not intended to be subject to surface mount processes under any circumstances.
The normal wave soldering process can be used with these devices where the device is subjected to a maximum wave temperature of 260°C for a period of
no more than 10 seconds. Within this time and temperature range, the integrity of the device’s plastic body will not be compromised and internal temperatures
within the converter will not exceed 175°C. Care should be taken to control manual soldering limits identical to that of wave soldering.
ISO9001
CERTIFIED
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
Technical enquiries - email: [email protected], tel: +44 (0)1908 615232
VKA50xSC.B01 Page 1 of 4
VKA50xSC
50 Watt Single Output Half Brick DC/DC Converter
SPECIFICATIONS, ALL MODELS
Specifications are at TCASE = +40°C nominal input voltage unless otherwise specified.
PARAMETER
INPUT
INPUT
Voltage Range
18
33
Maximum Input Current
VKA50LS
VKA50MS
Reflected Ripple Current
Input Ripple Rejection
No Load Input Current LS/MS
CONDITIONS
MIN
TYP
24
48
36
75
VDC
VDC
OUTPUT
OUTPUT
Rated Power
Set point Accuracy
Line Regulation
Load Regulation
Output Temperature Drift
Output Ripple, p-p
Output Current Limit Inception
Output Short-Circuit Current (2)
Output Overvoltage Limit
Transient Response
Peak Deviation
Settling Time
GENERAL
PARAMETER
ISOLATION
Input to Output
Input to Baseplate
Output to Baseplate
Resistance
Capacitance
Leakage Current
GENERAL
Efficiency, Line, Load, Temp. (3)
Switching Frequency
Remote Sense Compensation
Output Voltage Adjust Range
Remote On/Off Control Inputs
Primary
Sink Current-Logic Low
Vlow
Vhigh
Turn-on Time
Weight
TEMPERATURE
Operation/Specification
Storage
Shutdown Temperature
Thermal Impedance, case-ambient
Lead Solder Temperature
UNITS
VKA50LS
VIN = 16VDC
VIN = 27VDC
Peak - Peak
DC to 1KHz
VKA50MS
3.7
2.2
50
Power Dissipation LS/MS
No Load
Standby, Primary On/Off Disabled LS/MS
Inrush Charge
VIN = VINmax.
VKA50LS
VKA50MS
Quiescent Operating Current
Primary On/Off Disabled
PARAMETER
MAX
CONDITIONS
20
60
50/100
A
A
mA
dB
mA
3.6/4.8
0.18/0.4
W
W
8
MIN
TYP
0
High Line to Low Line
No Load to Rated Load
0.02
0.2
±.02
1%
130%
120%
125%
DC to 20MHz BW
test
50 to 100% Load Step
di/dt = 1.0A/μSec
VOUT, 1% of Nominal Output
0.520
0.360
mC
mC
12
mA
MAX
UNITS
50
1
0.05
0.5
W
%
%
%
%/°C
VOUT, Nom
lOUT, Nom
lOUT, Nom
V
150%
150%
135%
2%
100
CONDITIONS
MIN
Peak Test for 2 Seconds
1500
1500
500
10
TYP
VOUT, Nom
μSec
MAX
VDC
VDC
VDC
MΩ
pF
μA, rms
2000
180
VISO = 240VAC, 60Hz
400
12V & higher(4)
420
UNITS
440
0.5
KHz
V
VOUT, Nom
1.0
0.4
Open Collector
12.5
85 (3.0)
mA
V
-50% / +25%
Open Collector/Drain
Within 1% of Rated Output
Case Temperature
Case Temperature
Case Temperature
10.0
-40
-55
+100
+25
+25
+100
+125
+115
7.1
10 Seconds max
+300
mSec
g (oz.)
°C
°C
°C
°C/W
°C
NOTES: 1) See Typical Performance Curves, page 3
(2) Continuous Mode
(3) See graphs for Efficiency vs. Output Load, VIN, TCASE
(4) 3.3V Models Limited in Trim Down Range
(5) Consult Factory for Details
www.murata-ps.com
Technical enquiries - email: [email protected], tel: +44 (0)1908 615232
VKA50xSC.B01 Page 2 of 4
VKA50xSC
Power Dissipation (W)
TYPICAL PERFORMANCE CURVES
TCASE = +40°C nominal input voltage unless otherwise specified.
50 Watt Single Output Half Brick DC/DC Converter
Ambient Air Temperature (°C)
ORDERING
INFORMATION
VKA50
Device Family
Indicates 50 Watt Regulated Unit
Model Number
Selected from Table of Electrical Characteristics
Where:
x = Input Voltage (L = 24VDC; M = 48VDC)
zz = Output Voltage (03=3.3V, 05=5V, etc.)
Lead Length
0.200” - No Number
0.145” - (6)
0.110” - (8)
Remote On-Off Logic:
Positive - No Number
Negative - (1)
RoHS Compliant
www.murata-ps.com
xSzz
C
Technical enquiries - email: [email protected], tel: +44 (0)1908 615232
VKA50xSC.B01 Page 3 of 4
VKA50xSC
50 Watt Single Output Half Brick DC/DC Converter
MECHANICAL
NOTES:
All dimensions are in inches (millimeters).
PIN PLACEMENT TOLERANCE: ± 0.005”
0.530 MAX
[13.46]
MECHANICAL TOLERANCE: ± 0.015”
0.20 [5.1]
Marked with: specific modeL ordered, date code, job
code.
.040 [1.02] DIA.
7 PLACES
.081 [2.06] DIA.
2 PLACES
0.20 [5.1]
0.50 [12.7]
MATERIAL: Units are encapsulated in a low thermal
resistance molding compound which has excellent chemical
resistance and electrical properties in high humidity
environments and over a wide operating temperature
range. The encapsulant and outer shell of the unit have
UL94V-0 ratings. Lead material is solder plated to allow
ease of solderability.
.400 [10.16]
0.40 [10.16]
2.000
[50.80]
0.700
[17.78]
VKA50xSC
1.000
[25.40]
1.000
[25.40]
2.40
[61.0]
MAX
1.400
[35.56]
1.400
[35.56]
MOUNTING INSERTS M3 X 0.5 THRU, 4 PLACES
MAX. TORQUE, 8 IN/LBS
1.900
[48.26]
0.19 [4.8]
2.28
[57.91]
MAX
OUTPUT ADJUST VOLTAGE
OVP NOTE
This feature allows the user to accurately adjust the module’s
output voltage set point to a specified level. This is achieved
by connecting a resistor or potentiometer from the TRIM
terminal to either the +Vout terminal (for increased Vout) or
the -Vout terminal (for decreased Vout). The formulae below
describe the trim resistor value to obtain a Vout change of
$%. VO is output voltage prior to adjustment (3.3V, 5V, 12V,
15V, or 24V).
Radj - up =
+ $%) _ (100 + 2$%)
7
( Vo(100
1.225$% $% )
Radj - down =
Special attention should be given to the peak voltage
deviation during a dynamic load step when trimming the
output above the original set point to avoid tripping the
overvoltage protection circuit. Should an OVP condition
occur, the converter will go into a latch condition and
must be externally reset before it will return to normal
operation.
(100 $-%2)
7
USA:
Tucson (Az), Tel: (800) 547 2537, email: [email protected]
Canada: Toronto, Tel: (866) 740 1232, email: [email protected]
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
UK:
Milton Keynes, Tel: +44 (0)1908 615232, email: [email protected]
France:
Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: [email protected]
Germany: München, Tel: +49 (0)89-544334-0, email: [email protected]
www.murata-ps.com email: [email protected] ISO 9001 REGISTERED
Japan:
Tokyo, Tel: 3-3779-1031, email: [email protected]
Osaka, Tel: 6-6354-2025, email: [email protected]
Website: www.murata-ps.jp
China:
Shanghai, Tel: +86 215 027 3678, email: [email protected]
Guangzhou, Tel: +86 208 221 8066, email: [email protected]
07/28/08
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2008 Murata Power Solutions, Inc.
www.murata-ps.com
Technical enquiries - email: [email protected], tel: +44 (0)1908 615232
VKA50xSC.B01 Page 4 of 4