High-Density General-Purpose SPST Relays NI PXI-2569, NI PXIe-2569 NEW! ■ ■ 100 independent single-pole single-throw (SPST) relays Maximum switch capacity Up to 100 VDC, 100 VAC, CAT I Up to 1 A switching/1 A carry Latching relays 32,000-step scan list for deterministic scanning Fully software programmable 145 cycles/s Tight synchronization with instruments through hardware triggers Available in both PXI and PXI Express versions for optimal slot placement ■ ■ ■ ■ ■ ■ ■ ■ Operating Systems Windows XP/2000/NT ■ Recommended Software LabVIEW LabWindows™/CVI Measurement Studio for Visual C++ NI Switch Executive ■ ■ ■ ■ Other Compatible Software Visual Basic ANSI C/C++ ■ ■ Driver Software (included) NI-SWITCH ■ Compliance UL CE ■ ■ Overview Software The NI PXI-2569 and PXIe-2569 are 100-channel, general-purpose switch All National Instruments PXI switch modules are shipped with NI-SWITCH, an modules featuring SPST (Form A) armature relays. Ideal for medium-power IVI-compliant driver that offers complete functionality for all switch modules. automated test loads, these modules offer maximum relay density, with For additional assistance in configuring, programming, and managing higher- 100 latching relays in a single PXI slot. NI 2569 modules are able to switch channel-count switching systems, NI Switch Executive software provides an up to 100 VDC/100 VAC or up to 1 A. They are fully software-programmable easy-to-use, intelligent switch management and visual routing environment. and contain a 32,000-step scan list for deterministic scanning capability. Automatic Scanning Ordering Information NI 2569 modules are able to maximize throughput in automated test applications NI PXI-2569 ....................................................................................778572-69 by the use of scanning. Scanning improves throughput by downloading a list NI PXIe-2569 ..................................................................................780587-69 of up to 32,000 connections to the switch and cycling through the list using an Includes switch module and NI-SWITCH driver software. event (trigger) without any interruption from the host processor. You can NI Switch Executive most efficiently implement scanning by mating an NI 2569 with an instrument Development system......................................................................778546-01 such as the NI PXI-4070 6½-digit FlexDMM, which issues a trigger after Deployment engine ........................................................................778548-00 each measurement. BUY NOW For complete product specifications, pricing, and accessory information, call 800 813 3693 (U.S.) or go to ni.com/switches. High-Density General-Purpose SPST Relays Specifications Physical Specifications subject to change without notice. Visit ni.com/manuals for Relay types ............................................ Electromechanical, latching the latest full specifications. Contact material ................................... Palladium-ruthenium, gold covered I/O connectors ....................................... 200 POS LFH Matrix 50, receptacle Dimensions............................................ 10 by 17.5 cm (3.9 by 6.9 in.), 1 3U slot Input Characteristics Maximum switching voltage Channel-to-ground ............................ 300 V, CAT I Environment Channel-to-channel .......................... 300 V Operating temperature.......................... 0 to 55 °C 1A Storage temperature ............................. -20 to 70 °C (switching or carry, per channel) Relative humidity .................................. 5 to 85% noncondensing Pollution degree .................................... 2 Maximum current ............................. Simultaneous channels at maximum current (±35 °C) ................ Maximum switching power .................. 50 60 W, 62.5 VA (DC to 60 Hz) (per channel, resistive) Typical DC path resistance Safety Compliance ■ ■ Initial ................................................. <0.55 Ω End of life.......................................... ≤1 Ω Thermal EMF..................................... ≤12 μV Bandwidth (-3 dB, typical at 23 °C) ...... Approved at altitudes up to 2,000 m. ≤20 MHz IEC 61010-1, EN 61010-1 UL 61010-01, CSA 61010-1 Electromagnetic Compatibility This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use: EN 61326 (IEC 61326): Class A emissions; Basic immunity EN 55011 (CISPR 11): Group 1, Class A emissions AS/NZS CISPR 11: Group 1, Class A emissions FCC 47 CFR Part 15B: Class A emissions ICES-001: Class A emissions ■ Dynamic Characteristics Maximum speed.................................... ■ 145 cycles ■ Relay operate plus debounce time ■ Typical ............................................... 1 ms Maximum .......................................... 3.4 ms Expected relay life Mechanical ....................................... ■ 108 cycles Electrical Note: For EMC compliance, operate this product according to the documentation. CE Compliance This product meets the essential requirements of applicable European Directives as follows: 2006/95/EC; Low-Voltage Directive (safety) 2004/108/EC; Electromagnetic Compatibility Directive (EMC) ■ 10 VDC, 100 mADC, resistive ........... 2.5x106 cycles 10 VDC, 1 ADC, resistive .................. 1x106 cycles 30 VDC, 1 ADC resistive ................... 5x105 cycles 60 VDC, 1 ADC resistive ................... 1x105 cycles ■ BUY ONLINE at ni.com or C ALL 800 813 36 93 (U.S.) 2 NI Services and Support your needs around the globe and through PL AN MA IN NI has the services and support to meet IN TA the application life cycle – from planning and development through deployment and SERVICE NEEDS ongoing maintenance. We offer services P DE EL OP and service levels to meet customer LO Y requirements in research, design, validation, V DE and manufacturing. Visit ni.com/services. Local Sales and Technical Support In offices worldwide, our staff is local to the country, giving you access to engineers who speak your language. NI delivers industry-leading technical support through online knowledge bases, our applications engineers, and access to 14,000 measurement and automation professionals within NI Developer Exchange forums. Find immediate answers to your questions at ni.com/support. We also offer service programs that provide automatic upgrades to your application development environment and higher levels of technical support. Training and Certification Visit ni.com/ssp. NI training is the fastest, most certain route to productivity with our products. Hardware Services NI training can shorten your learning curve, save development time, and reduce maintenance costs over the application life cycle. We schedule instructor-led System Assurance Programs courses in cities worldwide, or we can hold a course at your facility. We also NI system assurance programs are designed to make it even easier for you offer a professional certification program that identifies individuals who have to own an NI system. These programs include configuration and deployment high levels of skill and knowledge on using NI products. services for your NI PXI, CompactRIO, or Compact FieldPoint system. The NI Basic Visit ni.com/training. System Assurance Program provides a simple integration test and ensures that Professional Services your system is delivered completely assembled in one box. When you configure your system with the NI Standard System Assurance Program, you can select Our NI Professional Services team is composed of NI applications and systems from available NI system driver sets and application development environments engineers and a worldwide National Instruments Alliance Partner program of to create customized, reorderable software configurations. Your system arrives more than 600 independent consultants and integrators. Services range from fully assembled and tested in one box with your software preinstalled. When start-up assistance to turnkey system you order your system with the standard program, you also receive system- integration. Visit ni.com/alliance. specific documentation including a bill of materials, an integration test report, a recommended maintenance plan, and frequently asked question documents. OEM Support Finally, the standard program reduces the total cost of owning an NI system We offer design-in consulting and product integration assistance if you want to online product advisors at ni.com/advisor to find a system assurance program use our products for OEM applications. For information about special pricing and services for OEM customers, visit ni.com/oem. by providing three years of warranty coverage and calibration service. Use the to meet your needs. Calibration Services NI recognizes the need to maintain properly calibrated devices for highaccuracy measurements. We provide manual calibration procedures, services to recalibrate your products, and automated calibration software specifically designed for use by metrology laboratories. Visit ni.com/calibration. Repair and Extended Warranty NI provides complete repair services for our products. Express repair and advance replacement services are also available. We offer extended warranties to help you meet project life-cycle requirements. Visit ni.com/services. ni.com ■ 800 813 3693 National Instruments ■ [email protected] ©2009 National Instruments. All rights reserved. CompactRIO, CVI, FieldPoint, FlexDMM, LabVIEW, Measurement Studio, National Instruments, National Instruments Alliance Partner, NI, and ni.com are trademarks of National Instruments. The mark LabWindows is used under a license from Microsoft Corporation. Windows is a registered trademark of Microsoft Corporation in the United States and other countries. Other product and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent from National Instruments and has no agency, partnership, or joint-venture relationship with National Instruments. 2009-11145-101-D