NI NIPXIE-2569

High-Density General-Purpose SPST Relays
NI PXI-2569, NI PXIe-2569 NEW!
■
■
100 independent single-pole
single-throw (SPST) relays
Maximum switch capacity
Up to 100 VDC, 100 VAC, CAT I
Up to 1 A switching/1 A carry
Latching relays
32,000-step scan list for
deterministic scanning
Fully software programmable
145 cycles/s
Tight synchronization with
instruments through hardware triggers
Available in both PXI and PXI Express
versions for optimal slot placement
■
■
■
■
■
■
■
■
Operating Systems
Windows XP/2000/NT
■
Recommended Software
LabVIEW
LabWindows™/CVI
Measurement Studio
for Visual C++
NI Switch Executive
■
■
■
■
Other Compatible Software
Visual Basic
ANSI C/C++
■
■
Driver Software (included)
NI-SWITCH
■
Compliance
UL
CE
■
■
Overview
Software
The NI PXI-2569 and PXIe-2569 are 100-channel, general-purpose switch
All National Instruments PXI switch modules are shipped with NI-SWITCH, an
modules featuring SPST (Form A) armature relays. Ideal for medium-power
IVI-compliant driver that offers complete functionality for all switch modules.
automated test loads, these modules offer maximum relay density, with
For additional assistance in configuring, programming, and managing higher-
100 latching relays in a single PXI slot. NI 2569 modules are able to switch
channel-count switching systems, NI Switch Executive software provides an
up to 100 VDC/100 VAC or up to 1 A. They are fully software-programmable
easy-to-use, intelligent switch management and visual routing environment.
and contain a 32,000-step scan list for deterministic scanning capability.
Automatic Scanning
Ordering Information
NI 2569 modules are able to maximize throughput in automated test applications
NI PXI-2569 ....................................................................................778572-69
by the use of scanning. Scanning improves throughput by downloading a list
NI PXIe-2569 ..................................................................................780587-69
of up to 32,000 connections to the switch and cycling through the list using an
Includes switch module and NI-SWITCH driver software.
event (trigger) without any interruption from the host processor. You can
NI Switch Executive
most efficiently implement scanning by mating an NI 2569 with an instrument
Development system......................................................................778546-01
such as the NI PXI-4070 6½-digit FlexDMM, which issues a trigger after
Deployment engine ........................................................................778548-00
each measurement.
BUY NOW
For complete product specifications, pricing, and accessory information,
call 800 813 3693 (U.S.) or go to ni.com/switches.
High-Density General-Purpose SPST Relays
Specifications
Physical
Specifications subject to change without notice. Visit ni.com/manuals for
Relay types ............................................
Electromechanical, latching
the latest full specifications.
Contact material ...................................
Palladium-ruthenium, gold covered
I/O connectors .......................................
200 POS LFH Matrix 50, receptacle
Dimensions............................................
10 by 17.5 cm (3.9 by 6.9 in.), 1 3U slot
Input Characteristics
Maximum switching voltage
Channel-to-ground ............................
300 V, CAT I
Environment
Channel-to-channel ..........................
300 V
Operating temperature..........................
0 to 55 °C
1A
Storage temperature .............................
-20 to 70 °C
(switching or carry, per channel)
Relative humidity ..................................
5 to 85% noncondensing
Pollution degree ....................................
2
Maximum current .............................
Simultaneous channels at
maximum current (±35 °C) ................
Maximum switching power ..................
50
60 W, 62.5 VA (DC to 60 Hz)
(per channel, resistive)
Typical DC path resistance
Safety Compliance
■
■
Initial .................................................
<0.55 Ω
End of life..........................................
≤1 Ω
Thermal EMF.....................................
≤12 μV
Bandwidth (-3 dB, typical at 23 °C) ......
Approved at altitudes up to 2,000 m.
≤20 MHz
IEC 61010-1, EN 61010-1
UL 61010-01, CSA 61010-1
Electromagnetic Compatibility
This product meets the requirements of the following EMC standards for
electrical equipment for measurement, control, and laboratory use:
EN 61326 (IEC 61326): Class A emissions; Basic immunity
EN 55011 (CISPR 11): Group 1, Class A emissions
AS/NZS CISPR 11: Group 1, Class A emissions
FCC 47 CFR Part 15B: Class A emissions
ICES-001: Class A emissions
■
Dynamic Characteristics
Maximum speed....................................
■
145 cycles
■
Relay operate plus debounce time
■
Typical ...............................................
1 ms
Maximum ..........................................
3.4 ms
Expected relay life
Mechanical .......................................
■
108 cycles
Electrical
Note: For EMC compliance, operate this product according to the documentation.
CE Compliance
This product meets the essential requirements of applicable European Directives
as follows:
2006/95/EC; Low-Voltage Directive (safety)
2004/108/EC; Electromagnetic Compatibility Directive (EMC)
■
10 VDC, 100 mADC, resistive ...........
2.5x106 cycles
10 VDC, 1 ADC, resistive ..................
1x106 cycles
30 VDC, 1 ADC resistive ...................
5x105 cycles
60 VDC, 1 ADC resistive ...................
1x105 cycles
■
BUY ONLINE at ni.com or C ALL 800 813 36 93 (U.S.)
2
NI Services and Support
your needs around the globe and through
PL
AN
MA
IN
NI has the services and support to meet
IN
TA
the application life cycle – from planning
and development through deployment and
SERVICE
NEEDS
ongoing maintenance. We offer services
P
DE
EL
OP
and service levels to meet customer
LO
Y
requirements in research, design, validation,
V
DE
and manufacturing.
Visit ni.com/services.
Local Sales and Technical Support
In offices worldwide, our staff is local to the country, giving you access to
engineers who speak your language. NI delivers industry-leading technical
support through online knowledge bases, our applications engineers,
and access to 14,000 measurement and automation professionals within NI
Developer Exchange forums. Find immediate answers to your questions at
ni.com/support.
We also offer service programs that provide automatic upgrades to your
application development environment and higher levels of technical support.
Training and Certification
Visit ni.com/ssp.
NI training is the fastest, most certain route to productivity with our products.
Hardware Services
NI training can shorten your learning curve, save development time, and reduce
maintenance costs over the application life cycle. We schedule instructor-led
System Assurance Programs
courses in cities worldwide, or we can hold a course at your facility. We also
NI system assurance programs are designed to make it even easier for you
offer a professional certification program that identifies individuals who have
to own an NI system. These programs include configuration and deployment
high levels of skill and knowledge on using NI products.
services for your NI PXI, CompactRIO, or Compact FieldPoint system. The NI Basic
Visit ni.com/training.
System Assurance Program provides a simple integration test and ensures that
Professional Services
your system is delivered completely assembled in one box. When you configure
your system with the NI Standard System Assurance Program, you can select
Our NI Professional Services team is composed of NI applications and systems
from available NI system driver sets and application development environments
engineers and a worldwide National Instruments Alliance Partner program of
to create customized, reorderable software configurations. Your system arrives
more than 600 independent consultants and integrators. Services range from
fully assembled and tested in one box with your software preinstalled. When
start-up assistance to turnkey system
you order your system with the standard program, you also receive system-
integration. Visit ni.com/alliance.
specific documentation including a bill of materials, an integration test report,
a recommended maintenance plan, and frequently asked question documents.
OEM Support
Finally, the standard program reduces the total cost of owning an NI system
We offer design-in consulting and product integration assistance if you want to
online product advisors at ni.com/advisor to find a system assurance program
use our products for OEM applications. For information about special pricing and
services for OEM customers, visit ni.com/oem.
by providing three years of warranty coverage and calibration service. Use the
to meet your needs.
Calibration Services
NI recognizes the need to maintain properly calibrated devices for highaccuracy measurements. We provide manual calibration procedures, services
to recalibrate your products, and automated calibration software specifically
designed for use by metrology laboratories. Visit ni.com/calibration.
Repair and Extended Warranty
NI provides complete repair services for our products. Express repair and
advance replacement services are also available. We offer extended warranties
to help you meet project life-cycle requirements. Visit ni.com/services.
ni.com
■
800 813 3693
National Instruments
■
[email protected]
©2009 National Instruments. All rights reserved. CompactRIO, CVI, FieldPoint, FlexDMM, LabVIEW, Measurement Studio, National Instruments, National Instruments Alliance Partner, NI, and ni.com are trademarks of
National Instruments. The mark LabWindows is used under a license from Microsoft Corporation. Windows is a registered trademark of Microsoft Corporation in the United States and other countries. Other product and
company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent from National Instruments and has no agency, partnership,
or joint-venture relationship with National Instruments. 2009-11145-101-D