NI NIPXIE-2527

32-Channel (2-Wire), 300 V Multiplexer Switches
NI PXI-2527, NI PXIe-2527 NEW!
■
■
64x1 1-wire, 32x1 2-wire, or 16x1
4-wire multiplexer
Maximum switch capacity
Up to 300 VDC/300 VAC, CAT I
Up to 2 A switching/2 A carry
Up to 60 W or 62.5 VA
Onboard relay counting
140 cycles/s
Fully software programmable
Deterministic operation with
hardware triggers
32,000-step scan list
Available in both PXI and PXI Express
versions for optimal slot placement
■
■
■
■
■
■
■
■
■
Operating Systems
Windows XP/2000/NT
■
Recommended Software
LabVIEW
LabWindows™/CVI
Measurement Studio
for Visual C++
NI Switch Executive
■
■
■
■
Other Compatible Software
Visual Basic
ANSI C/C++
■
■
Driver/Measurement Services
Software (included)
NI-SWITCH
NI-DAQmx
■
■
Compliance
UL
CE
■
■
Overview and Applications
Relay Count Tracking
The NI PXI-2527 and PXIe-2527 are high-voltage multiplexer switch modules
These switch modules count relay closures on each of their relays. Relay counts
designed for medium- to high-density automated test systems. With a
are incremented each time a relay is actuated. You can retrieve the counts,
switching capacity of up to 300 VDC/300 VAC and up to 2 A, an NI 2527
stored on board the modules, programmatically and use them for predictive
acts as an effective front end for NI 4070 and NI 4072 digital multimeters
maintenance to reduce unexpected system downtime.
(DMMs), offering simple channel expansion for voltage, current, resistance,
capacitance, or inductance measurements. NI provides multiple-channel
configurations including 64x1 one-wire, 32x1 two-wire, and 16x1 four-wire.
Each channel, using robust electromechanical relays, is capable of scanning
up to 140 channels/s. A cold-junction compensation (CJC) sensor is also
included in the front-mounting terminal block to assist in thermocouple
Simplified Signal Connectivity
Make signal connections for the NI 2527 modules in the TB-2627 front-mounting
screw-terminal block. Additionally, to simplify connectivity with a DMM, use the
HV6-BAN4 cable, which connects the banana jack inputs of a DMM to the COMs
of each multiplexer bank.
scanning applications.
Software
Automatic Scanning
All National Instruments PXI switch modules are shipped with NI-SWITCH, an
NI 2527 switches are able to maximize throughput in automated test applications
with the use of scanning. Scanning improves throughput by downloading a list
of up to 32,000 connections to the switches and cycling through the list using
an event (trigger) without any interruption from the host processor. You can most
efficiently implement scanning by mating an NI 2527 with an instrument such
as an NI 407x FlexDMM, which issues a trigger after each measurement.
IVI-compliant driver that offers complete functionality for all switch modules.
For additional assistance in configuring, programming, and managing higherchannel-count switching systems, NI Switch Executive software provides an
easy-to-use, intelligent switch management and visual routing environment.
Use the NI-SWITCH soft front panel for simple relay operations or debugging
switch code/execution.
32-Channel (2-Wire), 300 V Multiplexer Switches
Ordering Information
NI PXI-2527 ...................................................................................778572-27
NI PXIe-2527 ..................................................................................780587-27
Includes NI-SWITCH driver software.
Accessories
TB-2627 terminal block .................................................................779358-01
HV6-BAN4 DMM connectivity cable ...........................................192795-0R2
NI Switch Executive
Development system......................................................................778546-01
Deployment engine ........................................................................778548-00
BUY NOW
For complete product specifications, pricing, and accessory information,
call 800 813 3693 (U.S.) or go to ni.com/switches.
Safety Compliance
■
■
IEC 61010-1, EN 61010-1
UL 61010-01, CSA 61010-1
Electromagnetic Compatibility
This product meets the requirements of the following EMC standards for
electrical equipment for measurement, control, and laboratory use:
EN 61326 (IEC 61326): Class A emissions; Basic immunity
EN 55011 (CISPR 11): Group 1, Class A emissions
AS/NZS CISPR 11: Group 1, Class A emissions
FCC 47 CFR Part 15B: Class A emissions
ICES-001: Class A emissions
■
■
■
■
■
Note: For EMC compliance, operate this product according to the documentation.
CE Compliance
This product meets the essential requirements of applicable European Directives
as follows:
2006/95/EC; Low-Voltage Directive (safety)
■
2004/108/EC; Electromagnetic Compatibility Directive (EMC)
BUY ONLINE at ni.com or C ALL 800 813 36 93 (U.S.)
2
32-Channel (2-Wire), 300 V Multiplexer Switches
Specifications
Dynamic Characteristics
Specifications subject to change without notice. Visit ni.com/manuals for
Maximum speed....................................
the latest full specifications.
Relay operate time
Input Characteristics
Maximum switching voltage
Channel-to-ground ............................
300 V, CAT I
Channel-to-channel ..........................
300 V
Maximum switching/carry current ...
2A
Maximum switching power
AC systems .......................................
60 W, 62.5 VA
DC systems .......................................
Refer to Figure 1
140 cycles/s
Typical ...............................................
1 ms
Maximum ..........................................
3.4 ms
Expected relay life
Mechanical .......................................
1x108 cycles
Electrical
<30 mV, <10 mA, resistive ................
2.5x106 cycles
30 VDC, 2 ADC, resistive ..................
1x105 cycles
300 VDC, 60 mADC, resistive ...........
5x105 cycles
Physical
Relay types ............................................
Electromechanical, latching
Contact material....................................
Palladium-ruthenium, gold-covered
I/O connectors .......................................
100 POS HDI right-angle, male
Dimensions............................................
2 by 10 by 17.4 cm
(0.8 by 3.9 by 6.9 in.) single-slot, 3U
Environment
Operating temperature..........................
0 to 55 °C
Note: If you are using an NI 2527 with an NI PXI-101x or the NI PXI-1000B chassis,
operating temperature for the NI 2527 modules is 0 to 45 °C.
Figure 1. Maximum Switching Power for DC Loads (per channel).
Storage temperature .............................
-20 to 70 °C
Relative humidity ..................................
5 to 85% noncondensing
Pollution degree ....................................
2
Indoor use only.
Typical DC path resistance
Initial .................................................
<1½
End of life..........................................
>2½
Differential thermal EMF
Typical ...............................................
2.5 μV
Maximum ..........................................
<12 μV
Bandwidth (-3 dB)
1-wire................................................
>30 MHz
2-wire................................................
>25 MHz
BUY ONLINE at ni.com or C ALL 800 813 36 93 (U.S.)
3
NI Services and Support
your needs around the globe and through
PL
AN
MA
IN
NI has the services and support to meet
IN
TA
the application life cycle – from planning
and development through deployment and
SERVICE
NEEDS
ongoing maintenance. We offer services
P
DE
EL
OP
and service levels to meet customer
LO
Y
requirements in research, design, validation,
V
DE
and manufacturing.
Visit ni.com/services.
Local Sales and Technical Support
In offices worldwide, our staff is local to the country, giving you access to
engineers who speak your language. NI delivers industry-leading technical
support through online knowledge bases, our applications engineers,
and access to 14,000 measurement and automation professionals within NI
Developer Exchange forums. Find immediate answers to your questions at
ni.com/support.
We also offer service programs that provide automatic upgrades to your
application development environment and higher levels of technical support.
Training and Certification
Visit ni.com/ssp.
NI training is the fastest, most certain route to productivity with our products.
Hardware Services
NI training can shorten your learning curve, save development time, and reduce
maintenance costs over the application life cycle. We schedule instructor-led
System Assurance Programs
courses in cities worldwide, or we can hold a course at your facility. We also
NI system assurance programs are designed to make it even easier for you
offer a professional certification program that identifies individuals who have
to own an NI system. These programs include configuration and deployment
high levels of skill and knowledge on using NI products.
services for your NI PXI, CompactRIO, or Compact FieldPoint system. The NI Basic
Visit ni.com/training.
System Assurance Program provides a simple integration test and ensures that
Professional Services
your system is delivered completely assembled in one box. When you configure
your system with the NI Standard System Assurance Program, you can select
Our NI Professional Services team is composed of NI applications and systems
from available NI system driver sets and application development environments
engineers and a worldwide National Instruments Alliance Partner program of
to create customized, reorderable software configurations. Your system arrives
more than 600 independent consultants and integrators. Services range from
fully assembled and tested in one box with your software preinstalled. When
start-up assistance to turnkey system
you order your system with the standard program, you also receive system-
integration. Visit ni.com/alliance.
specific documentation including a bill of materials, an integration test report,
a recommended maintenance plan, and frequently asked question documents.
OEM Support
Finally, the standard program reduces the total cost of owning an NI system
We offer design-in consulting and product integration assistance if you want to
online product advisors at ni.com/advisor to find a system assurance program
use our products for OEM applications. For information about special pricing and
services for OEM customers, visit ni.com/oem.
by providing three years of warranty coverage and calibration service. Use the
to meet your needs.
Calibration Services
NI recognizes the need to maintain properly calibrated devices for highaccuracy measurements. We provide manual calibration procedures, services
to recalibrate your products, and automated calibration software specifically
designed for use by metrology laboratories. Visit ni.com/calibration.
Repair and Extended Warranty
NI provides complete repair services for our products. Express repair and
advance replacement services are also available. We offer extended warranties
to help you meet project life-cycle requirements. Visit ni.com/services.
ni.com
■
800 813 3693
National Instruments
■
[email protected]
©2009 National Instruments. All rights reserved. CompactRIO, CVI, FieldPoint, FlexDMM, LabVIEW, Measurement Studio, National Instruments, National Instruments Alliance Partner, NI, and ni.com are trademarks of
National Instruments. The mark LabWindows is used under a license from Microsoft Corporation. Windows is a registered trademark of Microsoft Corporation in the United States and other countries. Other product and
company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent from National Instruments and has no agency, partnership,
or joint-venture relationship with National Instruments. 2009-11120-101-D