WWW.PHIHONG.COM 19.6W Power Over Ethernet Adapter PSA20U High Power single port injector. Features • • • Fully Compliant detection, disconnect, over load and voltage control IEEE802.3af Diagnostic LEDs Non-Vented Case Applications • • • IP Telephones Wireless Network Access Points Blue Tooth Access Point Safety Approvals • • cUL/UL CE Mechanical Characteristics • • Length: 140mm (5.51in) Width: 65mm (2.55in) • UNH IOL Test Report • • Full Protection OCP, OVP Gigabit Compatible • • Security Camera IP Print Servers • TUV • • Height: 36mm (1.42in) Weight: 0.2Kg (0.44lb.) Output Specifications Model DC Output Voltage PSA20U-560(G) 56V Ripple And Noise* <500Hz 500Hz-150KHz 150KHz-500KHz 500KHz-1MHz Load Regulation Min. Max. 0A 0.35A Line Load ±4% Vp-p* 0.5 0.15 0.15 0.1 *As per IEEE802.3af Table 33-5. Phihong is not responsible for any error and change. Content is subject to change without notice. Please consult the factory and visit www.phihong.com for the most up-to-date specifications. PSA20U Characteristics INPUT: WWW.PHIHONG.COM AC Input Voltage Range EMC 90 to 264VAC FCC Part 15 Class B EN55022 Class B AC Input Voltage Rating 100 to 240VAC Isolation Test AC Input Current Primary to Secondary: 3000VAC for 1 minute 10mA Primary to F.G.: 1500VAC for 1 minute Output to F.G.: 1500VAC 0.5A(RMS) max. for 90VAC 0.35A(RMS) max. for 240VAC Immunity Leakage Current 0.25mA max. @ 254VAC 60Hz AC Input Frequency 47-63Hz AC Inrush Current 15A(RMS) max. for 115VAC 20A(RMS) max. for 230VAC OUTPUT: Total Output Power ESD: RS: EFT: Surge: CS: Voltage Dips Harmonic: EN61000-4-2. Level 3 EN61000-4-3. Level 2 EN61000-4-4. Level 2 EN61000-4-5. Level 3 EN61000-4-6. Level 2 EN61000-4-11 EN61000-3-2 Insulation Resistance Primary to secondary: >10M OHM 500VDC Primary to FC: >10M OHM 500VDC FEATURE: 19.6W Over Voltage/Current, Short Circuit Protection Efficiency 65% (typical) at Max. load, and 120VAC 60Hz Hold-up Time 16mS min. 120VAC and max. load Outputs equipped with short circuit protection and overload protection as per 802.3af specification The output can be shorted permanently without damage Indicators 60V max. at switch on and off at any AC line Phase Led #1 indicator for input power “on” GREEN Led #2 Indicator for fault-RED Led #3 Indicator that Detected and Connected to valid IEEE802.3af load-GREEN ENVIRONMENTAL: Input Connector Transient O/P Voltage Protection Temperature Operation Non-operation IEC320 inlet 3 pin 0 to +40°C -25 to +65°C Humidity Operation 5 to 90% Dimension Diagram Unit: mm (inch)