LABORATORY DLM Series 3000-4000 WATTS PROGRAMMABLE DC SUPPLY Features • • • • • • • High power density Preview push button Remote voltage sense & remote operation Calibration without removing covers Regulatory compliance Parrallel or series operation IEEE-488.2 and RS-232 interface options Specifications OPERATING INPUT Input Voltage 3KW:180-264VAC, single or three phase (<200VAC range limited to 40°C maximum) 4KW:180264VAC, three phase (<200VAC range limited to 40°C maximum) Frequency 47-63Hz for both single and three phase input Power Factor 0.95 typical with three phase input 0.98 typical with single phase input ENVIRONMENTAL Efficiency 5-8V Models: 82% typical 16-80V Models: 87% typical 150-600V Models: 85% typical Remote sense The maximum allowed sense line drop is 2V for 5V, 8V and 16V models and 5V for all other models Remote sense protection Remote programming Voltage, current (0-100%) and OVP (5-110%) of full scale can be programmed by selectable 0-5VDC, 010VDC, or 0-5kΩ Remote monitoring Voltage or current can be monitored with userselectable ranges, 0-5VDC or 0-10VDC Operating temperature 0°C to 50° (No De-rating) Storage temperature -40°C to 65°C Cooling Internal fan with over-temperature protection OUTPUT Voltage adjustment Zero to rated output Current adjustment Zero to rated output Ripple & Noise See table Regulation (Line or Load) Voltage: 0.05% of maximum rated output +2mV Current: 0.1% of maximum rated output Transient response Typically recovers in 1ms to within 1% of steady-state output voltage (greater than 50% Vmax) for a 70100% or 100-70% load change Stability +/-0.05% of maximum voltage or current over 8 hours after 15 minute warm-up time at fixed line, load and temperature Over-voltage protection Crowbar type adjustable from 5-110% rated output using front panel control (local or remote program selectable) Displays and indicators Two 3.5 digital LED displays indicate output voltage, output current and over-voltage setting. LED indication for power on, shut-down, remote, overvoltage, overtemperature and front panel lockout, constant voltage and constant current modes. IEEE-488.2 indicators include error, SRQ and address Software LabVIEW® driver for M9E/M85 (Contact Powerbox) Built-in protection Over-voltage (resets by cycling the Enable/standby switch), over-temperature (will automatically reset) Master/slave parallel operation, up to 2 units can be connected in parallel with active current sharing control to within 10% of each supply. Series operation, up to 3 units of the same model type can be connected in series (consult manual). Negative terminal rated at 150Vmax Above ground Operational features Temperature coefficient 0.02%/°C of maximum output voltage 0.03%/°C of maximum output current Regulatory compliance 488 Unit will not be damaged due to misconnection of the remote sense leads CE Mark on all models LABORATORY DLM Series 3000-4000 WATTS PROGRAMMABLE DC SUPPLY Selection Tables OUTPUT RATING REGULATION LINE AND LOAD METER ACCURACY VOLTAGE VOLTAGE CURRENT CURRENT CURRENT (0.05% OF VMAX (0.5% OF VMAX (0.75%OF IMAX (ADC) (0.1% OF IMAX) +2MV) +1 COUNT) +1 COUNT) MODEL VOLTAGE (VDC) DLM 5-350E 0-5 0-350 5mV 350mA 0.04V 4A DLM 5-450E 0-5 0-450 5mV 450mA 0.04V 5A DLM 8-350E 0-8 0-350 6mV 350mA 0.05V 4A DLM 8-450E 0-8 0-450 6mV 450mA 0.05V 5A DLM 16-185E 0-16 0-185 10mV 185mA 0.09V 3A DLM 16-250E 0-16 0-250 10mV 250mA 0.09V 3A DLM 32-95E 0-32 0-95 18mV 95mA 0.3V 0.8A DLM 32-125E 0-32 0-125 18mV 125mA 0.3V 1A DLM 40-75E 0-40 0-75 22mV 75mA 0.3V 0.7A DLM 40-100E 0-40 0-100 22mV 100mA 0.3V 0.9A DLM 60-50E 0-60 0-50 32mV 50mA 0.4V 0.5A DLM 60-66E 0-60 0-66 32mV 66mA 0.4V 0.6A DLM 80-37E 0-80 0-37 42mV 37mA 0.5V 0.4A DLM 80-50E 0-80 0-50 42mV 50mA 0.5V 0.5A DLM 150-20E 0-150 0-20 77mV 20mA 0.9V 0.3A DLM 150-26E 0-150 0-26 77mV 26mA 0.9V 0.3A DLM 300-10E 0-300 0-10 152mV 10mA 1.6V 0.09A DLM 300-13E 0-300 0-13 152mV 13mA 1.6V 0.11A DLM 600-5E 0-600 0-5 302mV 5mA 3.1V 0.05A DLM 600-6.6E 0-600 0-6.6 302mV 7mA 3.1V 0.06A PREVIEW ACCURACY MODEL OVP VOLTAGE CURRENT ADJUSTMENT (0.5% OF (1.0% OF RANGE (5% VMAX +1 IMAX +1 TO 110% OF VMAX) COUNT) COUNT) RIPPLE AND NOISE RIPPLE (RMS)* NOISE (P-P) STABILITY TEMP. COEFF. MAXIMUM CURRENT TOTAL VOLTAGE CURRENT VOLTAGE (0.03%/ REMOTE (0.05% OF (0.05% (0.02%/°C SENSE °C OF VMAX) OFIMAX) OF VMAX) DROP IMAX) DLM 5-350E 0.04V 5A 0.3-5.5V 12mV 100mV 3mV 175mA 1mV 105mA 2V DLM 5-450E 0.04V 6A 0.3-5.5V 12mV 100mV 3mV 225mA 1mV 135mA 2V DLM 8-350E 0.05V 5A 0.4-8.8V 12mV 100mV 4mV 175mA 1.6mV 105mA 2V DLM 8-450E 0.05V 6A 0.4-8.8V 12mV 100mV 4mV 225mA 1.6mV 135mA 2V DLM 16-185E 0.09V 3A 0.8-17.6V 10mV 100mV 8mV 93mA 3.2mV 55mA 2V DLM 16-250E 0.09V 4A 0.8-17.6V 10mV 100mV 8mV 125mA 3.2mV 75mA 2V DLM 32-95E 0.3V 1.1A 1.6-35V 10mV 100mV 16mV 48mA 6mV 30mA 5V DLM 32-125E 0.3V 1.4A 1.6-35V 10mV 100mV 16mV 63mA 6mV 38mA 5V DLM 40-75E 0.3V 0.9A 2-44V 10mV 100mV 20mV 38mA 8mV 23mA 5V DLM 40-100E 0.3V 1.1A 2-44V 10mV 100mV 20mV 50mA 8mV 30mA 5V DLM 60-50E 0.4V 0.6A 3-66V 15mV 100mV 30mV 25mA 12mV 15mA 5V DLM 60-66E 0.4V 0.8A 3-66V 15mV 100mV 30mV 33mA 12mV 19.8mA 5V DLM 80-37E 0.5V 0.5A 4-88V 15mV 120mV 40mV 19mA 16mV 12mA 5V DLM 80-50E 0.5V 0.6A 4-88V 15mV 120mV 40mV 25mA 16mV 15mA 5V DLM 150-20E 0.9V 0.3A 7.5-165V 30mV 200mV 75mV 10mA 30mV 6mA 5V DLM 150-26E 0.9V 0.4A 7.5-165V 30mV 200mV 75mV 13mA 30mV 7.8mA 5V DLM 300-10E 1.6V 0.11A 15-330V 60mV 300mV 150mV 5mA 60mV 3mA 5V DLM 300-13E 1.6V 0.14A 15-330V 60mV 300mV 150mV 6.5mA 60mV 3.9mA 5V DLM 600-5E 3.1V 0.06A 30-660V 100mV 500mV 300mV 2.5mA 120mV 1.5mA 5V DLM 600-6.6E 3.1V 0.08A 30-660V 100mV *RMS ripple typical from 20Hz to 300kHz Dimensions: 2RU or 88mm(H)x482mm(W)x508mm(D) ; Weight: 18.2kg 500mV 300mV 3.3mA 120mV 2mA 5V Your dependable power partner – www.powerbox.com.au 489 LABORATORY DLM Series 3000-4000 WATTS PROGRAMMABLE DC SUPPLY OPTIONS & ACCESSORIES J3 PROGRAM AND SENSE INPUT VOLTAGE OPTIONS M9E IEEE-488.2 and RS 232 Interfaces 3 Remote Shutdown Return(-) 15 Remote OVP Programing Input 16 M13 Locking shafts (front panel potentiometers) 4 Remote Programming Indicator 17 Remote Shutdown Input (+), Pos or Neg true logic selection with S1 +5 VDC Auxillary Output 1 mACurrent Source for OVP Programming OVP Status Indicator M51A Optically Isolated analog programming 5 Operating Mode Indicator 18 Overtemperature Shutdown Indicator M85 Multichannel Slave Interface 6 Status Indicator Return (-) 19 DC Voltage Monitor Output 7 Current Monitor Output N/C 20 M1 400 VAC input (4 kW only) M2 480 VAC input (4 kW only REMOTE INTERFACE OPTIONS PARALLEL CABLE 5361969-01 Paralleling Cable, one cable per slave unit RACK SLIDE KIT 105-330-26 Rack slide kit Technical Illustration 490 1 2 Remote Output Enable 14 10 Current Programing Unit 23 Remote/Local Voltage Control Select 1 mA Current Source for Voltage Programming 1 mA Current Source for Current Programming Remote/Local Current Control Select 11 N/C 24 N/C 12 Programming/Monitor Return 25 N/C 13 N/C 8 9 Voltage Programing Input 21 22