RECTRON RS101M

RS101M
THRU
RS107M
SINGLE-PHASE GLASS PASSIVATED
SILICON BRIDGE RECTIFIER
VOLTAGE RANGE 50 to 1000 Volts CURRENT 1.0 Ampere
FEATURES
*
*
*
*
Low leakage
Low forward voltage
Low cost
Mounting position: Any
RS-1M
MECHANICAL DATA
.146 (3.7)
.130 (3.3)
.582 (14.8)
* Epoxy: Device has UL flammability classification 94V-O
.406 (10.3)
.582 (14.8)
.543 (13.8)
.09 (2.3)
.043 (0.9)
.035 (0.6)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
.059 (1.5)
.043 (1.1)
.059 (1.5)
.043 (1.1)
.421 (10.7)
.559 (14.2)
.024 (0.6)
.016 (0.4)
Ratings at 25 o C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
.165 (4.2) .165 (4.2) .165 (4.2)
.149 (3.8) .149 (3.8) .149 (3.8)
For capacitive load, derate current by 20%.
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted)
SYMBOL
RS101M
RS102M
RS103M
RS106M
RS107M
UNITS
Maximum Recurrent Peak Reverse Voltage
RATINGS
VRRM
50
100
200
400
600
800
1000
Volts
Maximum RMS Voltage
VRMS
35
70
140
280
420
560
700
Volts
VDC
50
100
200
400
600
800
1000
Volts
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
at T A = 50 o C
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Typical Thermal Resistance (Note 1)
Operating and Storage Temperature Range
RS104M RS105M
IO
1.0
Amps
I FSM
30
Amps
R q JC
15
R q JA
50
T J, T STG
-55 to + 150
0
C/ W
0
C
ELECTRICAL CHARACTERISTICS (@TA=25 OC unless otherwise noted)
CHARACTERISTICS
Maximum Instantaneous Forward Voltage at 1.0A DC
Maximum DC Reverse Current
at Rated DC Blocking Voltage
@T A = 25 o C
@T A = 100 o C
SYMBOL
VF
IR
NOTES : 1. Thermal Resistance : Heat-sink case mounted or if PCB mounted.
2. "Fully ROHS compliant", "100% Sn plating (Pb-free)".
RS101M
RS102M
RS103M
RS104M RS105M
1.0
2.0
100
RS106M
RS107M
UNITS
Volts
mAmps
2006-12
AVERAGE FORWARD CURRENT, (A)
1.0
0.8
0.6
0.4
Single Phase Half Wave
60 Hz Inductive or
Resistive Load
0.2
0
0
50
100
150
INSTANTANEOUS FORWARD CURRENT, (A)
RATING AND CHARACTERISTICS CURVES ( RS101M THRU RS107M )
4
1.0
0.4
0.1
0.04
0.01
T A = 25 OC
Pulse Width = 300mS
1% Duty Cycle
0
O
FIG.1 TYPICAL FORWARD CURRENT
DERATING CURVE
1000
TA = 100 OC
100
10
TA = 25 OC
1.0
0.1
0
20
40
60
80
100
0.5
1.0
1.5
2.0
2.5
3.0
3.5
INSTANTANEOUS FORWARD VOLTAGE, (V)
PEAK FORWARD SURGE CURRENT, (A)
INSTANTANEOUS REVERSE CURRENT, (mA)
AMBIENT TEMPERATURE, ( C)
120
140
PERCENT RATED PEAK REVERSE VOLTAGE, (%)
FIG.3 TYPICAL REVERSE CHARACTERISTICS
30
FIG.2 TYPICAL INSTANTANEOUS
FORWARD CHARACTERISTICS
8.3mS Single Half Sine-Wave
JEDEC Method
25
20
15
10
5
0
1
2
5
10
20
50
100
NUMBER OF CYCLES AT 60Hz
FIG.4 MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.