RFE FSMD200-1812

Surface Mount PPTC
FSMD 1812 Series
FEATURES
RoHS
ü
AGENCY RECOGNITION
•UL (E211981)
•C-UL (E211981)
•TÜV (R50004084)
•1812 size Surface Mount
•Application: All high-density boards
•Operation Current: 140mA ~ 1.6A
•Maximum Voltage: 6V ~ 60V
•Temperature Range: -40°C to 85°C
•RoHS Compliant
ELECTRICAL CHARACTERISTICS (23°C)
Part Number
Hold
Current
Trip
Current
Rated
Voltage
Maximum
Current
Typical
Power
Max Time to Trip
Current
Time
Resistance Tolerance
RMIN
R1MAX
IH, A
IT, A
VMAX, Vdc
IMAX, A
Pd, W
Amp
Sec
OHMS
OHMS
FSMD014-1812
0.14
0.30
60
10
0.8
8.0
0.008
1.20
6.50
FSMD020-1812
0.20
0.40
30
10
0.8
8.0
0.02
0.80
5.00
FSMD035-1812
0.35
0.70
16
40
0.8
8.0
0.10
0.32
1.50
FSMD050-1812
0.50
1.00
16
40
0.8
8.0
0.15
0.15
1.00
FSMD075-1812
0.75
1.50
16
40
0.8
8.0
0.20
0.11
0.45
FSMD110-1812
1.10
2.20
8
100
0.8
8.0
0.30
0.04
0.21
FSMD110-16-1812
1.10
1.95
16
40
0.8
8.0
0.50
0.04
0.18
FSMD125-1812
1.25
2.50
6
40
0.8
8.0
0.40
0.05
0.14
FSMD150-1812
1.50
3.00
6
40
0.8
8.0
0.50
0.04
0.11
FSMD160-1812
1.60
3.20
6
40
0.8
8.0
0.50
0.03
0.10
FSMD200-1812
2.00
3.50
8
40
0.8
8.0
2.00
0.02
0.07
IH=Hold current-maximum current at which the device will not trip at 23°C still air.
IT=Trip current-maximum current at which the device will always trip at 23°C still air.
V MAX=Maximum voltage device can withstand without damage at its rated current (I MAX).
I MAX=Maximum fault current device can withstand without damage at rated voltage (V MAX).
Pd=Typical power dissipated-type amount of power dissipated by the device when in the tripped state in 23°C still air environment.
R MIN=Minimum device resistance at 23°C prior to tripping.
R1MAX=Maximum device resistance at 23°C measured 1 hour post trip.
Termination pad characteristics
Termination pad materials: Tin-plated copper
FSMD PRODUCT DIMENSIONS (MILLIMETERS)
D
B
A
Top and bottom view
Figure 1
Figure 2
Side view
Part
A
Number
B
Min
C
Max
Min
C
D
Min
Max
Max
Min
FSMD014-2920
4.37
4.73 3.07 3.41 0.60 0.90
0.30
FSMD020-2920
4.37
4.73 3.07 3.41 0.60 0.90
0.30
FSMD035-2920
4.37
4.73 3.07 3.41 0.40 0.70
0.30
FSMD050-2920
4.37
4.73 3.07 3.41 0.35 0.65
0.30
FSMD075-2920
4.37
4.73 3.07 3.41 0.35 0.65
0.30
FSMD110-2920
4.37
4.73 3.07 3.41 0.25 0.55
0.30
FSMD110-16-2920
4.37
4.73 3.07 3.41 0.25 0.90
0.30
FSMD125-2920
4.37
4.73 3.07 3.41 0.25 0.55
0.30
FSMD150-2920
4.37
4.73 3.07 3.41 0.25 0.55
0.30
FSMD160-2920
4.37
4.73 3.07 3.41 0.25 0.90
0.30
FSMD200-2920
4.37
4.73 3.07 3.41 0.50 0.90
0.30
RFE International • Tel:(949) 833-1988 • Fax:(949) 833-1788 • E-Mail [email protected]
C5ED04
REV 2007.8.14
Surface Mount PPTC
FSMD 1812 Series
RoHS
ü
THERMAL PRODUCT DIMENSIONS (MILLIMETERS)
Percent of Rated Hold and Trip
Current
Thermal Derating Curve, FSMD Series
200%
150%
100%
A= FSMD 075, 110, 110-16, 125, 150
160 & 200
B= FSMD 014, 020, 035 & 050
A
50%
B
0%
4- 0
2- 0
0
20
40
60
80
Ambient Temperature (C)
TYPICAL TIME-TO-TRIP AT 23°C
A = FSMD014
A B
C
D E FGH I J
B = FSMD020
100
C = FSMD035
10
Time-to-trip (S)
D = FSMD050
1
E = FSMD075
F = FSMD110/110-16
0.1
G = FSMD125
0.01
H = FSMD150
0.001
0.1
1
10
100
I = FSMD160
J
Fault current (A)
FSMD200
PAD LAYOUTS, SOLDER REFLOW AND REWORK RECOMMENDATIONS
The dimensions in the table below provide the recommended pad layout for each FSMD 1812 device
NOMINAL PAD DIMENSIONS (MILLIMETERS)
SOLDER RELOW
20 to 40 Seconds
260 °C
Ramp-up
3°C/Second Max
3.5
Ramp-down
6°C/Second Max
217 °C
f
200 °C
150 °C
1.78
3.45
1.78
Preheat
25 °C
60 to 180 Seconds
60 to 150 Seconds
Solder Reflow
Due to “Lead Free” nature, up to 40 seconds dwelling time for the soldering zone is strongly recommended.
1. Recommended reflow methods; IR, vapor phase oven, hot air oven.
2. The FSMD Series are suitable for use with wave-solder application methods. (Top side only)
3. Recommended maximum paste thickness is 0.25mm.
4. Devices can be cleaned by using standard industry methods and solvents.
5. Storage Environment: <30°C / 60%RH
Caution:
If reflow temperatures exceed the recommended profile, devices may not meet performance requirements.
Rework:
Use standard industry practices.
RFE International • Tel:(949) 833-1988 • Fax:(949) 833-1788 • E-Mail [email protected]
C5ED04
REV 2007.8.14