RHOMBUS-IND T-1074

LOW VOLTAGE INVERTER TRANSFORMER
Turns Ratio ( + 2% )
1CT : 1CT
PARAMETER
MIN.
Open Circuit Inductance *
TYP.
MAX.
3.0
UNITS
mHy
Leakage Inductance *
12
µHy
Interwinding Capacitance (CW/W) *
65
pF
Operating Frequency
20
KHz
Primary DC Resistance
0.250
ohms
Secondary DC Resistance
0.300
ohms
Isolation (HI-POT)
300
VRMS
Power Rating
10
Watts
Current
1
A
Operating Temperature
Designed as Driven NonSaturating Transformer at
Rated Voltage, Power and
Frequency.
0
0
+70
C
Materials used in construction of this component meet
or exceed UL Class B and can
be operated up to 1300 C
Flammability: Materials used
in the production of these
units meet requirements of
UL94-VO and IEC 695-2-2
needle flame test.
PHYSICAL DIMENSIONS
in inches (mm)
1.20
(30.5)
MAX.
SCHEMATIC
DIAGRAM
1.00
(25.4)
MAX.
.900
(22.86)
MAX.
1
6
2
5
3
4
.500
(12.70)
MIN.
.600
(15.24)
TYP.
1
# 22 AWG
Solderable
Leads, 6 ea.
.400
(10.16)
TYP.
2
.800
(20.32)
3
RHOMBUS INDUSTRIES INC.
FSCM NO. 16714
RHOMBUS P/N: T-1074
6
5
4
Rhombus
Industries Inc.
Transformers & Magnetic Products
CUST P/N:
DATE: 11/11/97
NAME:
SHEET:
1 OF 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971