RHOMBUS-IND T

10BASE T ISOLATION TRANSFORMER
Turns Ratio
+5%
1CT:1CT (Pins 1-3:16-14)
1CT:2CT (Pins 6-8:11-9)
PARAMETER
MIN.
MAX.
UNITS
Open Circuit Inductance (1-3)
@ 10 kHz-10mV
120
µH
Open Circuit Inductance (6-8)
@ 10 kHz-10mV
20
µH
Leakage Inductance (1-3, Short 16-14)
@1MHz-1V
0.4
µH
Leakage Inductance (6-8, Short 11-9)
@1MHz-1V
0.2
µH
Interwinding Capacitance
@100kHz-1V (1-3 to 14-16)
9.0
pF
Interwinding Capacitance
@100kHz-1V (6-8 to 11-9)
6.0
pF
DC Resistance Any Winding
0.9
ohms
HI-POT
1500
Fast Rise Times
Meets ECMA Requirements
IEEE 802.3 Compatible
(10BASE 2, 10BASE 5, & 10BASE T)
Flammability: Materials used in
the production of these units
meet requirements of UL94-VO
and IEC 695-2-2 needle flame
test.
Parts shipped in anti-static
tubes. 33 pieces per tube
VRMS
Dimensions in inches (mm)
SCHEMATIC DIAGRAM
1
16
2
15
3
14
6
11
7
10
8
9
RHOMBUS P/N: T-14954
CUST P/N:
DATE: 07/02/98
Rhombus
Industries Inc.
Transformers & Magnetic Products
www.rhombus-ind.com
NAME:
SHEET: 1 OF 1
15801 Chemical Lane,
Huntington Beach, CA 92649-1595
Phone: (714) 898-0960 FAX: (714) 896-0971