RHOMBUS-IND T

10BASE-T/ETHERNET ISOLATION TRANSFORMER
Turns Ratio
1CT:1CT & 1CT:1.41CT*
IEEE 802.3 & ECMA Compatible
*Pins 6 & 8 : 9 & 11
PARAMETER
MIN.
Open Circuit Inductance
MAX.
UNITS
Leakage Inductance
0.2
µHy
Interwinding Capacitance (CW/W)
12
pF
Rise Time
3.5
ns
ET
2.7
0.3
ohms
Secondary DC Resistance
0.3
ohms
2000
Parts shipped in anti-static
tubes. 34 pieces per tube
VµS
Primary DC Resistance
High Potential Test
Flammability: Materials used in
the production of these units
meet requirements of UL94-VO
and IEC 695-2-2 needle flame
test.
µHy
140
VRMS
Available on
Tape & Reel
Test Conditions: 100mV @ 100 KHz
Operating Temp. Range -450C to +850C
PHYSICAL DIMENSIONS
All dimensions in inches (mm):
SCHEMATIC DIAGRAM:
RHOMBUS P/N: T-14018
CUST P/N:
DATE: 10/23/97
Rhombus
Industries Inc.
Transformers & Magnetic Products
www.rhombus-ind.com
NAME:
SHEET: 1 OF 1
15801 Chemical Lane,
Huntington Beach, CA 92649-1595
Phone: (714) 898-0960 FAX: (714) 896-0971