RHOMBUS-IND T

Low Profile International Series Power Transformer
Part
Number
VA
T-61001
T-61002
T-61003
T-61004
T-61005
T-61006
T-61007
T-61008
T-61009
T-61010
T-61011
T-61012
T-61013
T-61014
T-61015
T-61016
T-61017
T-61018
T-61019
T-61020
T-61021
T-61022
T-61023
T-61024
T-61025
T-61026
T-61027
T-61028
T-61029
T-61030
T-61031
T-61032
T-61033
T-61034
T-61035
T-61036
T-61037
T-61038
T-61039
T-61040
T-61041
T-61042
2.5
5.0
10.0
20.0
30.0
56.0
2.5
5.0
10.0
20.0
30.0
56.0
2.5
5.0
10.0
20.0
30.0
56.0
2.5
5.0
10.0
20.0
12.0
56.0
2.5
5.0
10.0
20.0
30.0
56.0
2.5
5.0
10.0
20.0
30.0
56.0
2.5
5.0
10.0
20.0
30.0
56.0
Secondary Ratings
--- Series --- --- Parallel --V
I(Amps) V I (Amps)
10.0
10.0
10.0
10.0
10.0
10.0
12.6
12.6
12.6
12.6
12.6
12.6
16.0
16.0
16.0
16.0
16.0
16.0
20.0
20.0
20.0
20.0
20.0
20.0
24.0
24.0
24.0
24.0
24.0
24.0
28.0
28.0
28.0
28.0
28.0
28.0
36.0
36.0
36.0
36.0
36.0
36.0
0.25
0.5
1.0
2.0
3.0
5.6
0.2
0.4
0.8
1.6
2.4
4.4
0.15
0.31
0.62
1.25
1.9
3.5
0.12
0.25
0.5
1.0
1.5
2.8
0.1
0.21
0.42
0.83
1.25
2.33
0.09
0.18
0.36
0.72
1.06
2.0
0.07
0.14
0.28
0.56
0.82
1.56
5.0
5.0
5.0
5.0
5.0
5.0
6.3
6.3
6.3
6.3
6.0
6.0
8.0
8.0
8.0
8.0
8.0
8.0
10.0
10.0
10.0
10.0
10.0
10.0
12.0
12.0
12.0
12.0
12.0
12.0
14.0
14.0
14.0
14.0
14.0
14.0
18.0
18.0
18.0
18.0
18.0
18.0
NON-CONCENTRIC WINDING:
Primary and Secondary are wound
side-by-side rather than layered.
The added isolation reduces interwinding capacitance, eliminating
the need for an electro-static shield.
Additionally, it reduces radiated
magnetic fields.
0.5
1.0
2.0
4.0
6.0
11.2
0.4
0.8
1.6
3.2
4.8
8.8
0.3
0.62
1.25
2.5
3.8
7.0
0.24
0.5
1.0
2.0
3.0
5.6
0.2
0.42
0.84
1.66
2.5
4.66
0.18
0.36
0.72
1.44
2.12
4.0
0.14
0.28
0.56
1.12
1.64
3.12
Dual Primaries: 115/230V, 50/60 Hz
3 Flange Bobbin Design
6 VA Ratings
--
Hi-Pot 4000 VRMS
Parallel External
Connections:
6-3, 1-4 & 10-7, 9-12
FOR 2.5 T0 56.0 VA
L
H
W
Series External
Connections:
4-3 & 9-10
PRIMARY
1
4
3
B
A
6
C
A
Schematic
F
6
7
4
9
3
10
1
12
E
FOR 2.5 T0 10.0 VA
B
A
.187 MIN
(4.75)
7
A
10
9
FOR 2.5 TO 10.0 SERIES
12
SECONDARY
D
7
9
7
4
9
3
10
1
11
12
FOR 20.0 TO 56.0 SERIES
FOR 20.0 T0 56.0 VA
A
6
A A
Materials used in construction of
this component meet or exceed
UL Class B and can be operated
up to 130o C
10 11 12
SECONDARY
4 000 Volts RMS Hipot Test - Dual
Non-concentric Bobbins and insulating
Shroud Provide High Isolation and
Reduced Capacitance
Size
(VA)
2.5
5.0
10.0
20.0
30.0
56.0
Dimension in Inches
L
W
H
A*
1.625
1.625
1.875
2.250
2.625
3.000
1.313
1.313
1.563
1.875
2.188
2.500
1.125
1.375
1.375
1.625
1.563
1.813
.200
.200
.200
.400
.550
.600
B
C
.250
.400
.400
.400
.275
.300
1.000
1.000
1.140
1.460
1.680
1.900
D
.40
.55
.60
E
F
1.063
1.063
1.250
1.500
1.75 2.19
2.00 2.50
* For 20.0 TO 56.0 series secondary only, dimensions A is 1/2 of value shown
Specifications are subject to change without notice
Rhombus
Industries Inc.
Transformers & Magnetic Products
INTL-PC 11/98
www.rhombus-ind.com
15801 Chemical Lane
Huntington Beach, California 92649-1595
Phone: (714) 898-0960 • FAX: (714) 896-0971