RHOMBUS-IND T-802

Pulse Transformer
Turns Ratio ( + 2% )
Parameter
*Open Circuit Inductance
Oscillation Voltage = 1V
Oscillation Frequency = 100 KHz
1.3 : 1.0
Min.
Max.
1.0
mH
Pri.
Interwinding Capacitance (CW/W)
Oscillation Frequency = 100 KHz
15
pF
Primary DC Resistance
1.7
ohms
Secondary DC Resistance
1.0
ohms
Isolation (HI-POT)
Schematic
Diagram
Units
1000
Pin3 is Shield
VRMS
* Tested on Primary Pins 1 & 2
Physical Dimensions in inches (mm)
RHOMBUS P/N: T-802
CUST P/N:
DATE: 5/14/96
Rhombus
Industries Inc.
Transformers & Magnetic Products
NAME:
SHEET:
1 of 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971