RHOMBUS-IND TTLPWG-50

TTL Gated
Oscillators
TTL Pulse Width
Generator Modules
TTL Pulse Width
Discriminators
These gated oscillators permit synchronization of the output square wave with the high-tolow transition of the enable input. When the
enable is high, the output is held high. The
output will start with a high-to-low transition one
half-cycle after the input trigger. The output
frequency tolerance is ± 3%.
Triggered by the input's rising edge (input
pulse width 10 ns, min.), a pulse of specified
width will be generated at the output with a
propagation delay of 5 ± 2 ns (7 ± 2 ns, for
inverted output). High-to-low transitions will
not trigger the unit. Designed for output dutycycle less than 50%.
Input pulse widths greater than the Nominal
value (XX in ns from P/N TTLPD-XX) of the
module, will propagate with delay of (XX + 5ns)
± 5% or 2 ns, whichever is greater. Output
pulse width will follow the input width ± 7% or
4 ns, whichever is greater. Input pulse widths
less than the Nominal value will be suppressed.
E
Pin 8
IN
Pin 8
IN
Pin 8
OUT
Pin 1
OUT
Pin 1
OUT
Pin 1
TON
T OFF
TTLOS
Schematic
Vcc
ENABLE
14
8
T
D
PW
Vcc
OUT
14
13
SQUARE WAVE
OSCILLATOR
T
D
PW
OUT
PWIN > XX
PWIN < XX
T
D
PW
OUT
OUT
TTLPWG
Schematic
IN
Vcc
8
14
TTLPD
Schematic
IN
8
Pulse Width
Discriminator
Pulse Width
Control Circuit
1
7
1
7
1
7
OUT
GND
OUT
GND
OUT
GND
Electrical Specifications at 25OC
TTL Gated Oscillators
Part Number
Output Frequency
TTLOS-5
TTLOS-10
TTLOS-15
TTLOS-20
TTLOS-25
TTLOS-30
TTLOS-33
TTLOS-35
TTLOS-40
TTLOS-45
TTLOS-50
TTLOS-66
TTLOS-75
TTLOS-80
5 MHz
10 MHz
15 MHz
20 MHz
25 MHz
30 MHz
33 MHz
35 MHz
40 MHz
45 MHz
50 MHz
66 MHz
75 MHz
80 MHz
Electrical Specifications at 25OC
TTL Buffered Pulse Width Generator Modules
Output Pulse
Width (ns)
TTLPWG-5
5 ± 1.0
TTLPWG-7
7 ± 1.0
TTLPWG-10
10 ± 1.5
TTLPWG-15
15 ± 2.0
TTLPWG-20
20 ± 2.0
TTLPWG-25
25 ± 2.0
TTLPWG-30
30 ± 2.0
TTLPWG-35
35 ± 2.0
TTLPWG-40
40 ± 2.0
TTLPWG-45
45 ± 2.25
TTLPWG-50
50 ± 2.5
TTLPWG-60
60 ± 3.0
TTLPWG-80
80 ± 4.0
TTLPWG-100
100 ± 5.0
Part Number
Maximum
Freq. (MHz)
63
53
42
32
22
19
15
13
11
10
9
8
6
5
Electrical Specifications at 25OC
TTL Pulse Width Discriminator Modules
Suppressed
Passed
Pulse Width, Pulse Width,
Part Number
Max. (ns)
Min. (ns)
TTLPD-10
< 8.5
> 11.5
TTLPD-15
< 13.5
> 16.5
TTLPD-20
< 18.5
> 21.5
TTLPD-25
< 23.5
> 26.5
TTLPD-30
< 28.5
> 31.5
TTLPD-40
< 38.0
> 42.0
TTLPD-50
< 47.5
> 52.5
TTLPD-60
< 57.0
> 63.0
TTLPD-75
< 71.0
> 79.0
TTLPD-100
< 95.0
> 105.0
TTLPD-120
< 114.0
> 126.0
TTLPD-125
< 118.7
> 131.3
TTLPD-150
< 142.5
> 157.5
TTLPD-200
< 190.0
> 210.0
Dimensions in Inches (mm)
14-Pin Package with Unused Leads Removed Per Schematic
GENERAL: For Operating Specifications and Test Conditions, see Tables I and VI on page 5 of this catalog. Delays
specified for the Leading Edge.
.810
(20.57)
MAX.
Operating Temp. Range ................................. 0OC to +70OC
Temperature Coefficient ........................ 500ppm/OC typical
Supply Current, ICC
TTLPWG .............................. 35 mA typ., 55 mA max.
TTLPD .................................. 42 mA typ., 60 mA max.
TTLOS .................................. 15 mA typ., 30 mA max.
.245 .275
(6.22) (6.99)
TYP. MAX.
.020
(0.51)
TYP.
.100
(2.54)
TYP.
Specifications subject to change without notice.
Rhombus
Industries Inc.
.400
(10.16)
MAX.
.120
(3.05)
MIN.
.600
(15.24)
TYP.
For other values & Custom Designs, contact factory.
23
.050
(1.27)
TYP.
.010
(0.25)
TYP.
.300
(7.62)
TTL_PW 1/98
15801 Chemical Lane, Huntington Beach, CA 92649-1595
Tel: (714) 898-0960 • Fax: (714) 896-0971