RHOMBUS-IND ECLPWG-10

10K / 10KH
ECL Logic
Pulse Width
Control Modules
Electrical Specifications at 25OC
Electrical Specifications at 25OC
10KH ECL Pulse Width Generator Modules
10K ECL Pulse Width Generator Modules
Maximum
Freq. (MHz)
77.0
67.0
59.0
53.0
48.0
43.0
31.0
23.0
19.0
15.0
11.0
9.0
8.0
6.5
5.0
Part Number
ECLPWG-5
ECLPWG-6
ECLPWG-7
ECLPWG-8
ECLPWG-9
ECLPWG-10
ECLPWG-15
ECLPWG-20
ECLPWG-25
ECLPWG-30
ECLPWG-40
ECLPWG-50
ECLPWG-60
ECLPWG-75
ECLPWG-100
Triggered by the input's rising edge (input pulse
width 5 ns, min.), a pulse of specified width will
be generated at the output
High-to-low transitions will not trigger the unit.
Propagation Delay of 2 ns typ., 4 ns max.
10K ECL ECLPWG Series: Designed
for output duty-cycle less than 50%.
10KH ECL ECLHPW Series: Designed
for output duty-cycle less than 65%.
Output Pulse
Width (ns)
5 ± 1.00
6 ± 1.00
7 ± 1.00
8 ± 1.00
9 ± 1.00
10 ± 1.50
15 ± 2.00
20 ± 2.00
25 ± 2.00
30 ± 2.00
40 ± 2.00
50 ± 2.50
60 ± 3.00
75 ± 3.75
100 ± 5.00
Maximum
Freq. (MHz)
100.0
98.0
88.0
84.0
68.0
56.0
41.0
30.0
23.0
20.0
15.0
12.7
10.6
8.2
6.3
Part Number
ECLHPW-5
ECLHPW-6
ECLHPW-7
ECLHPW-8
ECLHPW-9
ECLHPW-10
ECLHPW-15
ECLHPW-20
ECLHPW-25
ECLHPW-30
ECLHPW-40
ECLHPW-50
ECLHPW-60
ECLHPW-75
ECLHPW-100
ECLPWG Schematic
Vcc OUT
IN
Pin 4
ECLHPW
OUT
IN
Pin 9
9
15
16
Pulse Width
Control Circuit
OUT
Pin 15
TD PW
OUT
TD PW
OUT
4
8
Vcc
IN
Vee
Schematic
Vcc
IN
16
9
Pulse Width
Control Circuit
OUT
Pin 3
1
Output Pulse
Width (ns)
5 ± 1.00
6 ± 1.00
7 ± 1.00
8 ± 1.00
9 ± 1.00
10 ± 1.50
15 ± 2.00
20 ± 2.00
25 ± 2.00
30 ± 2.00
40 ± 2.00
50 ± 2.50
60 ± 3.00
75 ± 3.75
100 ± 5.00
TD PW
OUT
TD PW
1
OUT
2
8
3
Vcc OUT OUT
Vee
Dimensions in Inches (mm)
16-Pin Package with Unused Leads Removed Per Schematic
.810
(20.57)
MAX.
GENERAL: For Operating Specifications and Test Conditions, see
Tables IV, V and VII on page 5 of this catalog. Delays specified for
the Leading Edge.
.400
(10.16)
MAX.
.260 .300
(6.60) (7.62)
TYP. MAX.
Operating Temp. Range, ECLPWG ........................... -40O to +85OC
Temperature Coefficient of PW ........................... 300ppm/OC typical
Supply Current, IEE , ECLPWG .................. 40 mA typ., 65 mA max.
.120
(3.05)
MIN.
Operating Temp. Range, ECLHPW ................................ 0O to +75OC
Temperature Coefficient of PW ........................... 300ppm/OC typical
Supply Current, IEE , ECLHPW ................... 50 mA typ., 75 mA max.
.050
(1.27)
TYP.
.300
(7.62)
.020
(0.51)
TYP.
.100
(2.54)
TYP.
100K ECL Logic Delay Modules
.520
(13.21)
MAX.
1.300
(33.02)
MAX
Contact Factory for Data Sheets
Dimensions in Inches (mm)
24-Pin Package with Unused Leads
Removed Per Schematic
Buffered with 100K Series 300 Logic
8 Equal Delay Taps Series: DDECL
.030 .350
(0.76) (8.89)
TYP. MAX
4-Bit Programmable Series: PPECL2
Stable Delay vs. Temperature: 300 ppm/ C
.050
(1.27)
TYP.
Operating Temperature Range 0OC to +85OC
VCCA VEE
19
24
.010
(0.25)
TYP.
.120
(3.05)
MIN.
O
IN
.010
(0.25)
TYP.
VCC
18
.400
(10.16)
.020
(0.51)
TYP.
.100
(2.54)
TYP.
13
P4
P3
P2
VEE
P1
22
21
20
19
18
17
Passive
Delay
Network
PPECL2
4-Bit 100K
Schematic
DDECL
8-Tap 100K
Schematic
IN
100K ECL
16 to 1 MUX
Output
Buffer
Internal Termination
100 Ohm Thevenin to -2V
1
3
4
5
Vcc
1
2
3
Specifications subject to change without notice.
Rhombus
Industries Inc.
6
7
VCC VCCA
8
9
10
11
12
4
5
6
7
8
6
7
8
VCC VCCA OUT
For other values & Custom Designs, contact factory.
28
ECLPW 1/98
15801 Chemical Lane, Huntington Beach, CA 92649-1595
Tel: (714) 898-0960 • Fax: (714) 896-0971