Thermoelectric Module Datasheets RMT Ltd Thermoelectric module type 1ML06-023-xx is available in four different ceramics versions. Cost-effective Al2O3 ceramics versions or high performance AlN ceramics versions are available. Please, select the appropriate type to check the complete datasheet. 1ML06-023-xx 1ML06-023-xxt 1ML06-023-xxAN025 1ML06-023-xxAN05 RMT Standard Al2O3 0.5mm ceramics version. TEC total height from 1.6mm to 2.4mm RMT Special Thin Al2O3 0.25mm ceramics version. TEC total height from 1.1mm to 1.9mm RMT Standard AlN 0.25mm ceramics version. TEC total height from 1.1mm to 1.9mm RMT Special Version with thick AlN 0.5mm ceramics. TEC total height from 1.6mm to 2.4mm Thermoelectric Sub-Mounts (TEC + Package assembled) are available 53 Leninskij prosp. Moscow 119991 Russia, ph: +7-499-132-6817, fax: +7-499-783-3664, web: www.rmtltd.ru Copyright 2008. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice. Page 1 of 1 Thermoelectric Module Datasheet RMT Ltd Performance Parameters ΔTmax K Type Qmax W 1ML06-023-XX Imax A Umax V AC R Ohm H mm h mm 1ML06-023-xx (N=23) Al2O3 0.5mm ceramics version 1ML06-023-05 69 5.2 3.4 1ML06-023-09 71 3.1 2.0 1ML06-023-12 71 2.3 1.5 2.8 0.68 1.7 0.5 1.20 2.1 0.9 1.60 2.4 1.2 Performance data are given at 300K, vacuum Technical Drawing Options available A. TEC Assembly: Solder Sn-Sb (Tmelt=230°C) C. Ceramics Surface Options D. Thermistor (optional) 1. Blank ceramics Can be mounted to cold side 2. Metallized: ceramics edge. Calibration 2.1 Ni / Sn(Bi) B. Ceramics: is available. 2.2 Gold plating 1.Pure Al2O3(100%) 3. Metallized and pre-tinned: 2.Alumina (Al2O3 - 96%) E. Terminal wires 3.1 Solder 94 (Pb-Sn-Bi, Tmelt=94°C) 3.Aluminum Nitride (AlN) 1. Pre-tinned Copper 3.2 Solder 117 (In-Sn, Tmelt=117°C) 2. Insulated Wires 3.3 Solder 138 (Sn-Bi, Tmelt=138°C) 100% Al2O3 used as standard 3. Insulated Color Coded 3.4 Solder 183 (Pb-Sn, Tmelt=183°C) 53 Leninskij prosp. Moscow 119991 Russia, ph: +7-499-132-6817, fax: +7-499-783-3664, web: www.rmtltd.ru Copyright 2008. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice. Page 1 of 3 Thermoelectric Module Datasheet RMT Ltd Performance Plots 1ML06-023-05 Performance Plots 1ML06-023-09 Color Legend: Imax, 0.8 Imax, 0.6 Imax, 0.4 Imax 53 Leninskij prosp. Moscow 119991 Russia, ph: +7-499-132-6817, fax: +7-499-783-3664, web: www.rmtltd.ru Copyright 2008. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice. Page 2 of 3 Thermoelectric Module Datasheet RMT Ltd Performance Plots 1ML06-023-12 Color Legend: Imax, 0.8 Imax, 0.6 Imax, 0.4 Imax Application Tips 1. Never heat TE module more than 200˚C (TEC assembled at 230˚C). 2. Never use TE module without attached heat sink at hot (bottom) side. 3. Connect TE module to DC power supply according to polarity. 4. Do not apply DC current higher than Imax. Installation 1. Mechanical Mounting. TEC is placed between two heat exchangers . This construction is fixed by screws or in another mechanical way. It is suitable for large modules (with dimensions 30x30mm and larger). Miniature types require other assembling methods in most cases. 2. Soldering. This method is suitable for a TE module with metallized outside surfaces. RMT provides this option and also makes pre-tinning for TE modules. 3. Glueing. It is an up-to-date method that is used by many customers due to availability of glues with good thermoconductive properties. A glue is usually based on some epoxy compound filled with some thermoconductive material such as graphite or diamond powders, silver, SiN and others. The application of a specific type depends on application features and the type of a TE module. Object being cooled Object being cooled TEC TEC 1 3 2 Screw mounting Heatsink Soldering Heatsink Gluing 53 Leninskij prosp. Moscow 119991 Russia, ph: +7-499-132-6817, fax: +7-499-783-3664, web: www.rmtltd.ru Copyright 2008. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice. Page 3 of 3 Thermoelectric Module Datasheet RMT Ltd Performance Parameters ΔTmax K Type Qmax W 1ML06-023-XXt Imax A Umax V AC R Ohm H mm h mm 1ML06-023-xxt (N=23) Al2O3 0.25mm ceramics version 1ML06-023-05t 69 5.2 3.4 1ML06-023-09t 71 3.1 2.0 1ML06-023-12t 71 2.3 1.5 2.8 0.68 1.2 0.5 1.20 1.6 0.9 1.60 1.9 1.2 Performance data are given at 300K, vacuum Technical Drawing Options available A. TEC Assembly: Solder Sn-Sb (Tmelt=230°C) C. Ceramics Surface Options D. Thermistor (optional) 1. Blank ceramics Can be mounted to cold side 2. Metallized: ceramics edge. Calibration 2.1 Ni / Sn(Bi) B. Ceramics: is available. 2.2 Gold plating 1.Pure Al2O3(100%) 3. Metallized and pre-tinned: 2.Alumina (Al2O3 - 96%) E. Terminal wires 3.1 Solder 94 (Pb-Sn-Bi, Tmelt=94°C) 3.Aluminum Nitride (AlN) 1. Pre-tinned Copper 3.2 Solder 117 (In-Sn, Tmelt=117°C) 2. Insulated Wires 3.3 Solder 138 (Sn-Bi, Tmelt=138°C) 100% Al2O3 used as standard 3. Insulated Color Coded 3.4 Solder 183 (Pb-Sn, Tmelt=183°C) 53 Leninskij prosp. Moscow 119991 Russia, ph: +7-499-132-6817, fax: +7-499-783-3664, web: www.rmtltd.ru Copyright 2008. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice. Page 1 of 3 Thermoelectric Module Datasheet RMT Ltd Performance Plots 1ML06-023-05t Performance Plots 1ML06-023-09t Color Legend: Imax, 0.8 Imax, 0.6 Imax, 0.4 Imax 53 Leninskij prosp. Moscow 119991 Russia, ph: +7-499-132-6817, fax: +7-499-783-3664, web: www.rmtltd.ru Copyright 2008. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice. Page 2 of 3 Thermoelectric Module Datasheet RMT Ltd Performance Plots 1ML06-023-12t Color Legend: Imax, 0.8 Imax, 0.6 Imax, 0.4 Imax Application Tips 1. Never heat TE module more than 200˚C (TEC assembled at 230˚C). 2. Never use TE module without attached heat sink at hot (bottom) side. 3. Connect TE module to DC power supply according to polarity. 4. Do not apply DC current higher than Imax. Installation 1. Mechanical Mounting. TEC is placed between two heat exchangers . This construction is fixed by screws or in another mechanical way. It is suitable for large modules (with dimensions 30x30mm and larger). Miniature types require other assembling methods in most cases. 2. Soldering. This method is suitable for a TE module with metallized outside surfaces. RMT provides this option and also makes pre-tinning for TE modules. 3. Glueing. It is an up-to-date method that is used by many customers due to availability of glues with good thermoconductive properties. A glue is usually based on some epoxy compound filled with some thermoconductive material such as graphite or diamond powders, silver, SiN and others. The application of a specific type depends on application features and the type of a TE module. Object being cooled Object being cooled TEC TEC 1 3 2 Screw mounting Heatsink Soldering Heatsink Gluing 53 Leninskij prosp. Moscow 119991 Russia, ph: +7-499-132-6817, fax: +7-499-783-3664, web: www.rmtltd.ru Copyright 2008. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice. Page 3 of 3 Thermoelectric Module Datasheet RMT Ltd Performance Parameters ΔTmax K Type Qmax W 1ML06-023-XXAN Imax A Umax V AC R Ohm H mm h mm 1ML06-023-xxAN (N=23) AlN 0.25mm ceramics version 1ML06-023-05AN 70 5.7 3.5 1ML06-023-09AN 72 3.2 2.0 1ML06-023-12AN 72 2.4 1.5 2.9 0.68 1.2 0.5 1.20 1.6 0.9 1.60 1.9 1.2 Performance data are given at 300K, vacuum Technical Drawing Options available A. TEC Assembly: Solder Sn-Sb (Tmelt=230°C) B. Ceramics: 1.Pure Al2O3(100%) 2.Alumina (Al2O3 - 96%) 3.Aluminum Nitride (AlN) 100% AlN used as standard C. Ceramics Surface Options D. Thermistor (optional) 1. Blank ceramics Can be mounted to cold side 2. Metallized: ceramics edge. Calibration 2.1 Ni / Sn(Bi) is available. 2.2 Gold plating 3. Metallized and pre-tinned: E. Terminal wires 3.1 Solder 94 (Pb-Sn-Bi, Tmelt=94°C) 1. Pre-tinned Copper 3.2 Solder 117 (In-Sn, Tmelt=117°C) 2. Insulated Wires 3.3 Solder 138 (Sn-Bi, Tmelt=138°C) 3. Insulated Color Coded 3.4 Solder 183 (Pb-Sn, Tmelt=183°C) 53 Leninskij prosp. Moscow 119991 Russia, ph: +7-499-132-6817, fax: +7-499-783-3664, web: www.rmtltd.ru Copyright 2008. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice. Page 1 of 3 Thermoelectric Module Datasheet RMT Ltd Performance Plots 1ML06-023-05AN Performance Plots 1ML06-023-09AN Color Legend: Imax, 0.8 Imax, 0.6 Imax, 0.4 Imax 53 Leninskij prosp. Moscow 119991 Russia, ph: +7-499-132-6817, fax: +7-499-783-3664, web: www.rmtltd.ru Copyright 2008. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice. Page 2 of 3 Thermoelectric Module Datasheet RMT Ltd Performance Plots 1ML06-023-12AN Color Legend: Imax, 0.8 Imax, 0.6 Imax, 0.4 Imax Application Tips 1. Never heat TE module more than 200˚C (TEC assembled at 230˚C). 2. Never use TE module without attached heat sink at hot (bottom) side. 3. Connect TE module to DC power supply according to polarity. 4. Do not apply DC current higher than Imax. Installation 1. Mechanical Mounting. TEC is placed between two heat exchangers . This construction is fixed by screws or in another mechanical way. It is suitable for large modules (with dimensions 30x30mm and larger). Miniature types require other assembling methods in most cases. 2. Soldering. This method is suitable for a TE module with metallized outside surfaces. RMT provides this option and also makes pre-tinning for TE modules. 3. Glueing. It is an up-to-date method that is used by many customers due to availability of glues with good thermoconductive properties. A glue is usually based on some epoxy compound filled with some thermoconductive material such as graphite or diamond powders, silver, SiN and others. The application of a specific type depends on application features and the type of a TE module. Object being cooled Object being cooled TEC TEC 1 3 2 Screw mounting Heatsink Soldering Heatsink Gluing 53 Leninskij prosp. Moscow 119991 Russia, ph: +7-499-132-6817, fax: +7-499-783-3664, web: www.rmtltd.ru Copyright 2008. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice. Page 3 of 3 Thermoelectric Module Datasheet RMT Ltd Performance Parameters ΔTmax K Type Qmax W 1ML06-023-XXAN Imax A Umax V AC R Ohm H mm h mm 1ML06-023-xxAN (N=23) AlN 0.5mm ceramics version 1ML06-023-05AN 70 5.7 3.5 1ML06-023-09AN 72 3.2 2.0 1ML06-023-12AN 72 2.4 1.5 2.9 0.68 1.7 0.5 1.20 2.1 0.9 1.60 2.4 1.2 Performance data are given at 300K, vacuum Technical Drawing Options available A. TEC Assembly: Solder Sn-Sb (Tmelt=230°C) B. Ceramics: 1.Pure Al2O3(100%) 2.Alumina (Al2O3 - 96%) 3.Aluminum Nitride (AlN) 100% AlN used as standard C. Ceramics Surface Options D. Thermistor (optional) 1. Blank ceramics Can be mounted to cold side 2. Metallized: ceramics edge. Calibration 2.1 Ni / Sn(Bi) is available. 2.2 Gold plating 3. Metallized and pre-tinned: E. Terminal wires 3.1 Solder 94 (Pb-Sn-Bi, Tmelt=94°C) 1. Pre-tinned Copper 3.2 Solder 117 (In-Sn, Tmelt=117°C) 2. Insulated Wires 3.3 Solder 138 (Sn-Bi, Tmelt=138°C) 3. Insulated Color Coded 3.4 Solder 183 (Pb-Sn, Tmelt=183°C) 53 Leninskij prosp. Moscow 119991 Russia, ph: +7-499-132-6817, fax: +7-499-783-3664, web: www.rmtltd.ru Copyright 2008. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice. Page 1 of 3 Thermoelectric Module Datasheet RMT Ltd Performance Plots 1ML06-023-05AN Performance Plots 1ML06-023-09AN Color Legend: Imax, 0.8 Imax, 0.6 Imax, 0.4 Imax 53 Leninskij prosp. Moscow 119991 Russia, ph: +7-499-132-6817, fax: +7-499-783-3664, web: www.rmtltd.ru Copyright 2008. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice. Page 2 of 3 Thermoelectric Module Datasheet RMT Ltd Performance Plots 1ML06-023-12AN Color Legend: Imax, 0.8 Imax, 0.6 Imax, 0.4 Imax Application Tips 1. Never heat TE module more than 200˚C (TEC assembled at 230˚C). 2. Never use TE module without attached heat sink at hot (bottom) side. 3. Connect TE module to DC power supply according to polarity. 4. Do not apply DC current higher than Imax. Installation 1. Mechanical Mounting. TEC is placed between two heat exchangers . This construction is fixed by screws or in another mechanical way. It is suitable for large modules (with dimensions 30x30mm and larger). Miniature types require other assembling methods in most cases. 2. Soldering. This method is suitable for a TE module with metallized outside surfaces. RMT provides this option and also makes pre-tinning for TE modules. 3. Glueing. It is an up-to-date method that is used by many customers due to availability of glues with good thermoconductive properties. A glue is usually based on some epoxy compound filled with some thermoconductive material such as graphite or diamond powders, silver, SiN and others. The application of a specific type depends on application features and the type of a TE module. Object being cooled Object being cooled TEC TEC 1 3 2 Screw mounting Heatsink Soldering Heatsink Gluing 53 Leninskij prosp. Moscow 119991 Russia, ph: +7-499-132-6817, fax: +7-499-783-3664, web: www.rmtltd.ru Copyright 2008. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice. Page 3 of 3