SCHURTER D8STTD

D8STTD
Non resettable fuses
www.schurter.com/pg01_2
220 VAC · 125 VDC · Time-Lag T
Description
OU
T
Miniature Fuse, 6.3 x 32 mm, Time-Lag T, GAM T1, 1.25 A, 220 VAC, 125 VDC
References
-High Breaking Capacity
-Type D8STTD (0.16 - 1.25 A), A12TD (1.6 A - 30 A)
General Product Information
Weblinks
Approvals, RoHS, CHINA-RoHS, e-Store, Distributor-Stock-Check,
Accessories, Product Change Notification (PCN)
Technical Data
220 VAC, 125 VDC
0.16 - 1.25 A
50 A
Time-Lag T
Fuseholder / Clip
-40 °C to 55 °C
40/055/21 acc. to IEC 60068-1
Ceramic
2.8 g
0 °C to 60 °C, max. 70% r.h.
, Current, Voltage, Characteristic
Dimensions
Shocks
Bumps
Salt Mist
acc. to NF C 20-706 / IEC 60068-2-6,
test Fc
acc. to NF C 20-706 / IEC 60068-2-27
acc. to NF C 20-729 / IEC 60068-2-29
acc. to NF C 20-711 / IEC 60068-2-11
32 mm
ø 6.35 ±0.06
AS
Resistance to Vibration
E-
Rated Voltage
Rated Current
Breaking Capacity
Characteristic
Mounting Admissible Ambient Air Temp.
Climatic Category
Material: Tube
Unit Weight
Storage Conditions
Product Marking
0
PH
32 -1
Pre-Arcing Time
Rated Current In
0.16 A - 1.25 A
1.1 x In min.
1.45 x In max.
60 min
60 min
3.0 x In min. 3.0 x In max. 5.0 x In min. 5.0 x In max.
4s
9s
1s
4s
Fuses
D8STTD
Non resettable fuses
www.schurter.com/pg01_2
Variants
Rated Voltage [VDC]
0.16
220
125
0.2
220
125
0.25
220
0.31
0.4
Breaking
Capacity
Voltage Drop
1.0 In typ.
[mV]
Power Dissipation 1.1 In
typ. [mW]
Melting I²t
10.0 Intyp.
[A²s]
1)
1100
210
1.6
l
l
7035.7310
1)
1100
265
1.9
l
l
7035.7320
125
1)
570
180
1.4
l
l
7035.7330
220
125
1)
500
195
7.2
l
220
125
1)
505
255
6.3
l
l
7035.7350
0.5
220
125
1)
450
285
1.9
l
l
7035.7360
0.63
220
125
1)
460
370
11
l
0.8
220
125
1)
320
325
12
l
l
7035.7380
1
220
125
1)
405
515
15
l
l
7035.7390
1.25
220
125
1)
315
505
23
l
l
7035.7410
1) 5 kA @ 125 VAC/DC, p.f. 0.3 - 0.4 / 50 A @ 220 VAC, p.f. ≥ 0.9
Packaging Unit Small Box Pack (10 pcs.)
Time-Current-Curves
100000
D8STTD
A12TD
1000
100
7035.7370
10
1
0.1
0.01
0.001
1
AS
Time in Seconds
7035.7340
E-
10000
Order Number
T
Rated Voltage [VAC]
OU
Rated Current [A]
10
PH
Multiple of Rated Current In
The
specifications, descriptions and illustrations indicated in this document are based on
Fuses