70° C
Description
-Panel Mount:
Screw-on mounting from front side
-3 Functions:
Appliance Inlet Protection class I, Line Switch 1‑pole, Line-filter in standard version
-Quick connect terminals 6.3 x 0.8 mm
-Alternative: version without line filter KEB1 -We recommend for new applications the new type DC12 Approvals
-VDE License Number: 40004665 (FKS)
-UL License Number: E72928 (FKS)
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
Characteristics
-All single elements are already wired
-Line switch non-illuminated
-With EMC-shield
-Qualified for use in equipment according IEC/EN 60950
References
General Product Information
Weblinks
Approvals, RoHS, CHINA-RoHS, Mating Connectors, e-Store,
Distributor-Stock-Check, Accessories
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 10 A @ Ta 40 °C / 125 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class 1 acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Thermoplastic, black, UL 94V-0
Appliance-Inlet/-Outlet
Line Switch
Line Filter
MTBF
EMC Products
C14 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class 1
Rocker switch 1-pole, non-illuminated,
acc. to IEC 61058-1
Technical details
Standard Version, IEC 60939, IEC
60601‑1, UL 1283, UL 544, EN 133
200, CSA C22.2 no. 8
Technical details
> 2'100'000 h acc. to MIL-HB-217 F
KFB1
Power Entry Modules with Line Filter
www.schurter.com/pg06
Dimensions
60.5 mm
+0.1
2
27.2 -0.2
9.5
33
M3
34
32.8 ±0.1
x28.5 ±0.1
+0.1
36 ±0.1
+0.3
0
6.3x0.8
3.2x90°
31.2 -0.2
36 ±0.2
+0.3
0
5
46
29
R3
60.5
44
Technical Data of Filter-Components
Rated Current
[A]
Filter-Type
Inductances
L [mH]
Capacitance
CX [nF]
Capacitance
CY [nF]
1
Standard Version
2 x 10
68
2.2
2
Standard Version
2x4
68
2.2
4
Standard Version
2 x 1.5
68
2.2
6
Standard Version
2 x 0.8
68
2.2
10
Standard Version
2 x 0.3
68
2.2
Diagrams
1) Line
2) Load
Attenuation Loss
Standard version
1A
- - - - differential mode _____ common mode
2A
4A
10 A
EMC Products
6A
KFB1
Power Entry Modules with Line Filter
www.schurter.com/pg06
Variants
Rated Current
[A]
Filter-Type
Order Number
1
Standard Version
4302.5001
2
Standard Version
4302.5002
4
Standard Version
4302.5003
6
Standard Version
4302.5004
10
Standard Version
4302.5005
Packaging unit 10 Pcs Accessories
Description
Assorted Covers
Rear Cover
0859.0075
Cord retaining kits
Cord retaining strain relief
Countersunk, B
4700.0002
Mating Outlets/Connectors
Category / Description
Appliance Outlet Overview complete
IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal
4787
IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal
4788
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal
5091
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal
5092
Appliance Outlet further types to KFB1
Connector Overview complete
IEC Connector C15, Rewireable, Straight
0101
IEC Connector C15A, Rewireable, Straight
0102
IEC Connector C15A, Rewireable, Straight
0102-G
IEC Connector C15A, Rewireable, Angled
0112
IEC Connector C13, Rewireable, Angled
4012
Connector further types to KFB1
...
Power Cord Overview complete
Power Cord with IEC Connector C13, Angled
0311
Power Cord with IEC Connector C13, Angled
3011
Power Cord with IEC Connector C13, Angled
3012
Power Cord with IEC Connector C13, Angled
3013
Power Cord with IEC Connector C13
3020
Power Cord further types to KFB1
...
The specifications, descriptions and illustrations indicated in this document
are based on
EMC Products
current information. All content is subject to modifications and amendments.