SCHURTER DD22

DD22
Power Entry Modules with Line Filter
www.schurter.com/pg06
IEC Appliance Inlet C14 with Filter, Fuseholder 1- or 2-pole, Line Switch 2-pole, for PCB Mounting
Standard- or Medical-Filter
Fuse drawer must be ordered separately (see
accessories).
C14
70° C
Description
Characteristics
Approvals
Other versions on request
-Panel Mount:
Screw-on mounting on PCB, from rear-side
-4 Functions:
Appliance Inlet Protection class I, Line Switch 2-pole, Fuseholder for
fuse-links 5 x 20 mm 1‑ or 2‑pole, Line filter in standard and medical
version
-PCB solder terminals
-Alternative: version without line filter DD21 -Ultra-compact design. Ideal for low profile designs
-All single elements are already wired
-For added safety "Extra-Safe" fuse drawers are available
Fuse drawer meets requirements of medical standard IEC/EN 60601-1
The fuse drawer can only be opened with the aid of a tool
The fuseholder is accessible from the equipment front
-Ideal for application with high transient loads
-Qualified for use in equipment according IEC/EN 60950
-Fuse drawer 1-pole, plus spare fuse case
-Fuse drawer 2-pole, with shorting bar
-Other rocker marking
-Line switch, illuminated -Line switch 1-pole
-Medical version M80
-Protection class II, 70°C
-VDE License Number: 40001522
-UL License Number: E72928
References
General Product Information
Weblinks
Approvals, RoHS, CHINA-RoHS, Mating Connectors, e-Store,
Distributor-Stock-Check, Accessories
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 10 A @ Ta 40 °C / 250 VAC; 50/60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (1 min/50 Hz)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class 1 acc. to IEC 61140
For PCB mounting 3 mm additional
quick connect 6.3 x 0.8 mm
Screw-on mounting: max 3 mm
Mounting screw torque max 0.5 Nm
Thermoplastic, black, UL 94V-0
Appliance-Inlet/-Outlet
Fuseholder
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Line Switch
Line Filter
MTBF
EMC Products
C14 acc. to IEC/EN 60320-1
UL 498 CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class 1
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per
pole
Admissible power acceptance at higher ambient temperature see derating
curves
Rocker switch 2-pole, non-illuminated,
acc. to IEC 61058-1
Technical details
Standard and Medical Version, IEC
60939, IEC 60601‑1, UL 1283, UL 544,
EN 133 200, CSA C22.2 no. 8
Technical details
> 2'000'000 h acc. to MIL-HB-217 F
DD22
Power Entry Modules with Line Filter
www.schurter.com/pg06
Dimensions
Screw version
66.3 mm
66.3
60.9
49.2
9.8
3.5
0.85
1)
3.55
2.15
4.5
2.8
R
4.
30.8
16.25
49.6 ±0.10
11.5 15.25
58.5±0.15
58.5
30.8 ±0.20
57.5
57.5 ±0.2
4
4
4.
3.
R
41
48
3.6
1.6
1.6
+0
.
0 10
+0
.
0 10
3.6
1) all terminals with 1.25 x 0.8
2) Quick connect terminal 6.3 x 0.8
Technical Data of Filter-Components
Rated Current
[A]
Filter-Type
Inductances
L [mH]
Capacitance
CX [nF]
Capacitance
CY [nF]
R [MΩ]
1
Standard Version
2 x 10
100
2.2
1
2
Standard Version
2x4
100
2.2
1
4
Standard Version
2 x 1.5
100
2.2
1
6
Standard Version
2 x 0.8
100
2.2
1
10
Standard Version
2 x 0.3
100
2.2
1
1
Medical Version (M5)
2 x 10
100
-
1
2
Medical Version (M5)
2x4
100
-
1
4
Medical Version (M5)
2 x 1.5
100
-
1
6
Medical Version (M5)
2 x 0.8
100
-
1
10
Medical Version (M5)
2 x 0.3
100
-
1
EMC Products
.10
0
+0
1.6
3.55 ±0.1
2)
6.6
6.2
11.5 ±0.15 14.75 ±0.15
6.05 ±0.1
6
3.
30.1 ±0.10
31.5
33
17
29.7
3.4
5 ±0
.0
5
R
4.
35
11.55
47.6
DD22
Power Entry Modules with Line Filter
www.schurter.com/pg06
Filter Medical M5
non illuminated
1) Line
2) Load
1) Line
2) Load
Derating Curves
1-pole
2-pole
Admissible power acceptance in Watt
2.0
1.5
I = 1.0 In
I = 0.7 In
1.0
I = < < In
0.5
0.0
0
20
40
60
80
100
Admissible power acceptance in Watt per pole
Diagrams
Filter Standard
non illuminated
Ambient air temperature Ta °C
1.6
1.4
1.2
I = 1.0 In
1.0
0.8
I = 0.7 In
0.6
I = << In
0.4
0.2
0.0
0
20
40
60
80
100
Ambient air temperature Ta °C
Attenuation Loss
Standard version
1A
- - - - differential mode _____ common mode
2A
4A
6A
2A
4A
6A
10 A
Medical version (M5)
1A
10 A
EMC Products
DD22
Power Entry Modules with Line Filter
www.schurter.com/pg06
Variants
Fuse drawer must be ordered separately (see accessories).
Rated Current
[A]
Filter-Type
Fuseholder
Line Switch
Order Number
1
Standard Version
1-pole
2-pole
DD22.1111.1111
2
Standard Version
1-pole
2-pole
DD22.2111.1111
4
Standard Version
1-pole
2-pole
DD22.4111.1111
6
Standard Version
1-pole
2-pole
DD22.6111.1111
10
Standard Version
1-pole
2-pole
DD22.9111.1111
1
Standard Version
2-pole
2-pole
DD22.1121.1111
2
Standard Version
2-pole
2-pole
DD22.2121.1111
4
Standard Version
2-pole
2-pole
DD22.4121.1111
6
Standard Version
2-pole
2-pole
DD22.6121.1111
10
Standard Version
2-pole
2-pole
DD22.9121.1111
1
Medical Version (M5)
2-pole
2-pole
DD22.1321.1111
2
Medical Version (M5)
2-pole
2-pole
DD22.2321.1111
4
Medical Version (M5)
2-pole
2-pole
DD22.4321.1111
6
Medical Version (M5)
2-pole
2-pole
DD22.6321.1111
10
Medical Version (M5)
2-pole
2-pole
DD22.9321.1111
Packaging unit 20 Pcs Required Accessory
Description
Fusedrawer 2
Fusedrawer with and without Voltage Selector Insert
Fingergrip, 2-pole
4301.1401
Extra-Safe, 2-pole
4301.1403
Fingergrip, 1-pole
4301.1405
Extra-Safe, 1-pole
4301.1407
...
Mating Outlets/Connectors
Category / Description
Appliance Outlet Overview complete
IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal
4787
IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal
4788
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal
5091
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal
5092
Appliance Outlet further types to DD22
Connector Overview complete
IEC Connector C15, Rewireable, Straight
0101
IEC Connector C15A, Rewireable, Straight
0102
IEC Connector C15A, Rewireable, Straight
0102-G
IEC Connector C15A, Rewireable, Angled
0112
IEC Connector C13, Rewireable, Angled
4012
Connector further types to DD22
...
EMC Products
DD22
Power Entry Modules with Line Filter
www.schurter.com/pg06
Category / Description
Power Cord Overview complete
Power Cord with IEC Connector C13, Angled
0311
Power Cord with IEC Connector C13, Angled
3011
Power Cord with IEC Connector C13, Angled
3012
Power Cord with IEC Connector C13, Angled
3013
Power Cord with IEC Connector C13
3020
Power Cord further types to DD22
...
The specifications, descriptions and illustrations indicated in this document
are based on
EMC Products