SCHURTER KM00120511

KM
Power entry modules without line filter
www.schurter.com/pg05
IEC Appliance Inlet C14 with Fuseholder 2-pole, Line Switch 1- or 2-pole
Plug removal necessary for fuse
replacement
KM with shield
C14
70° C
Description
-Panel Mount:
Snap-in version from front side
-3 Functions:
Appliance Inlet Protection class I, Line Switch 2-pole, Fuseholder for
fuse-links 5 x 20 mm 1‑ or 2‑pole
-Quick connect terminals 4.8 x 0.8 mm
-Alternative: version with line filter KMF -Alternative: version for screw mounting DD11 -With cover on rear-side
Approvals
Characteristics
-Ultra-compact design. Small dimensions in front of and behind the panel
-All single elements are already wired
-For added safety "Extra-Safe" fuse drawers are available
Fuse drawer meets requirements of medical standard IEC/EN 60601-1
The fuse drawer can only be opened with the aid of a tool
The fuseholder is accessible from the equipment front
-Ideal for application with high transient loads
-Qualified for use in equipment according IEC/EN 60950
Other versions on request
-Fuse drawer 1-pole, plus spare fuse case
-Fuse drawer 2-pole, with shorting bar
-Line switch 1-pole
-Other rocker marking
-Protection class II, 70°C
-VDE License Number: 40021981
-UL License Number: E93617
References
General Product Information
Weblinks
Approvals, RoHS, CHINA-RoHS, Mating Connectors, e-Store,
Distributor-Stock-Check, Accessories
Technical Data
Ratings IEC
Ratings UL/CSA
Dielectric Strength
Allowable Operation Temp.
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
10 A / 250 VAC; 50 Hz
10 A / 250 VAC; 60 Hz
> 2.5 kVAC between L-N
> 3 kVAC between L/N-PE
(1 min/50 Hz)
-25 °C to 70 °C
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class 1 acc. to IEC 61140
Quick connect terminals 4.8 x 0.8 mm
, tin-plated
Snap-in: 1/1.5/2/2.5 mm
(all steps with one variant)
Thermoplastic, black, UL 94V-0
Appliance Inlet
Fuseholder
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Line Switch
Connectors
C14 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class 1
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
5 x 20: 2 W (1 pole)/ 1.4 W (2-pole) per
pole
Choose fuse-links for 2-pole version
in such a way that the typical power
acceptance is less than 1.4 W for each
pole
Admissible power acceptance at higher ambient temperature see derating
curves
Rocker switch 2-pole, non-illuminated,
acc. to IEC 61058-1
Technical details
KM
Power entry modules without line filter
www.schurter.com/pg05
Dimensions
KM without shield
50 mm
30.35
.5
R1
25.7
L’
0
PE’
S ±0.05
3.2
30.5
26.15
3
m
10.7
ax
.R
0.
50
46.8
+0.10
47 -0.05
N’
+0.10
27.8
2.5
28 -0.05
KM with shield
30.4
.5
R1
25.7
L’
30.5
10
26.2
2.5
Diagrams
with shield
1) Line
2) Load
PE’
S ±0.05
Connectors
28.5
3
m
10.7
ax
.R
50
47.5
+0.10
47.8 -0.05
N’
0.
0
+0.10
28.8 -0.05
KM
Power entry modules without line filter
www.schurter.com/pg05
Derating Curves
1-pole
2-pole
1.5
I = 1.0 In
I = 0.7 In
1.0
I = << In
0.5
0.0
0
20
40
60
80
1.4
Admissible power acceptance in Watt
per pole
Admissible power acceptance in Watt
2.0
100
Ambient air temperature Ta °C
1.2
1.0
I = 1.0 In
0.8
I = 0.7 In
0.6
I = << In
0.4
0.2
0.0
0
20
40
60
80
100
Ambient air temperature Ta °C
Variants
Fuse drawer must be ordered separately (see accessories).
Fingergrip and Extra Safe. The same drawer as used by type KEA.
Fuseholder
Line Switch
EMC-Shielding
Order Number
1-pole
2-pole
-
KM00.1205.11
2-pole
2-pole
-
KM00.1105.11
1-pole
2-pole
With EMC-shield and without line filter
KM01.1205.11
2-pole
2-pole
With EMC-shield and without line filter
KM01.1105.11
Packaging unit 50 Pcs Required Accessory
Description
Fusedrawer 2
Fusedrawer with and without Voltage Selector Insert
Fingergrip, 2-pole
4301.1401
Extra-Safe, 2-pole
4301.1403
Fingergrip, 1-pole
4301.1405
Extra-Safe, 1-pole
4301.1407
...
Accessories
Assorted Covers
Rear Cover
0859.0076
Cord retaining kits
Cord retaining strain relief
Flat head, A
4700.0001
Connectors
KM
Power entry modules without line filter
www.schurter.com/pg05
Mating Outlets/Connectors
Category / Description
Appliance Outlet Overview complete
IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal
4787
IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal
4788
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal
5091
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal
5092
Appliance Outlet further types to KM
Connector Overview complete
IEC Connector C15, Rewireable, Straight
0101
IEC Connector C15A, Rewireable, Straight
0102
IEC Connector C15A, Rewireable, Straight
0102-G
IEC Connector C15A, Rewireable, Angled
0112
IEC Connector C13, Rewireable, Angled
4012
Connector further types to KM
...
Power Cord Overview complete
Power Cord with IEC Connector C13, Angled
0311
Power Cord with IEC Connector C13, Angled
3011
Power Cord with IEC Connector C13, Angled
3012
Power Cord with IEC Connector C13, Angled
3013
Power Cord with IEC Connector C13
3020
Power Cord further types to KM
...
The
specifications, descriptions and illustrations indicated in this document are based on
Connectors
current information. All content is subject to modifications and amendments.