SCHURTER KPF8.1

KPF
Power Entry Modules with Line Filter
www.schurter.com/pg06
Filter for Backpack Mounting to KP01
Standard- or Medical-Filter
KP01 Base Module
(not enclosed)
Description
Characteristics
-Component:
Snap-in version from rear-side
-1 Function:
Line filter in standard and medical version
-For PCB mounting
-Only in combination with base-module type KP01
-Line filter for "backpack" mounting for modules type KP01 (snaps onto
rear of KP01)
-Electrical connection done on the PCB
-Qualified for use in equipment according IEC/EN 60950
References
General Product Information
Approvals
Weblinks
-VDE License Number: 104869
-UL License Number: E72928
-CSA License Number: 97784
Approvals, RoHS, CHINA-RoHS, Mating Connectors, e-Store,
Distributor-Stock-Check, Accessories
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Material: Housing
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 10 A @ Ta 40 °C / 125 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-25 °C to 70 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class 1 acc. to IEC 61140
For PCB mounting
Thermoplastic, black, UL 94V-0
Line Filter
MTBF
Dimensions
53.4 mm
Standard and Medical Version, IEC
60939, IEC 60601‑1, UL 1283, UL 544,
EN 133 200, CSA C22.2 no. 8
Technical details
> 2'600'000 h acc. to MIL-HB-217 F
53.34
7.62
56.1
27.94
10.16
12.7
EMC Products
16.85
5.08
3.82
12.7
16.45
17.9
34.85
41.05
18.5
4.5
2
2.9
36.5
7.62
32
36
2
7.62 7.62
KPF
Power Entry Modules with Line Filter
www.schurter.com/pg06
Drilling diagram
Layout to diagram A
Drilling diagram
Layout to diagram B
53.34
53.34
27.94
27.94
7.62 7.62 7.62 7.62 12.7 10.16
1)
+0.1
0 (N’ L’ N
L E)
1.6
1) Minimum ground plane
+0.1
0 (N’ L’ N
1) Optimal ground plane
Technical Data of Filter-Components
Rated Current
[A]
Filter-Type
Capacitance
CX [nF]
Capacitance
CY [nF]
R [MΩ]
Standard Version
2 x 10
100
2.2
-
2
Standard Version
2x4
100
2.2
-
4
Standard Version
2x2
100
2.2
-
6
Standard Version
2x1
100
2.2
-
8
Standard Version
2 x 0.6
100
2.2
-
10
Standard Version
2 x 0.4
100
2.2
-
1
Medical Version (M5)
2 x 10
100
-
1
2
Medical Version (M5)
2x4
100
-
1
4
Medical Version (M5)
2x2
100
-
1
6
Medical Version (M5)
2x1
100
-
1
8
Medical Version (M5)
2 x 0.6
100
-
1
10
Medical Version (M5)
2 x 0.4
100
-
1
1) Line
2) Load
Inductances
L [mH]
1
Diagrams
Standard line filter
L
E
8.9
3.82
8.9
3.82
1.6
N’ L’ N
EMI filtering of equipment
emissions
1) Line
2) Load
EMC Products
L E)
21.6
1)
12.7
E
21.6
L
12.7
N’ L’ N
7.62 7.62 7.62 7.62 12.7 10.16
KPF
Power Entry Modules with Line Filter
www.schurter.com/pg06
Attenuation Loss
- - - - differential mode _____ common mode
Standard version
1A
2A
8A
10 A
Medical version (M5)
1A
2A
8A
10 A
4A
6A
4A
6A
Variants
Rated Current
[A]
Filter-Type
Order Number
1
Standard Version
KPF1.1
2
Standard Version
KPF2.1
4
Standard Version
KPF4.1
6
Standard Version
KPF6.1
8
Standard Version
KPF8.1
10
Standard Version
KPF0.1
1
Medical Version (M5)
KPF1.3
2
Medical Version (M5)
KPF2.3
4
Medical Version (M5)
KPF4.3
6
Medical Version (M5)
KPF6.3
8
Medical Version (M5)
KPF8.3
10
Medical Version (M5)
KPF0.3
Packaging unit 50 Pcs The specifications, descriptions and illustrations indicated in this document
are based on
EMC Products