160PC...-PCB Series Fully signal conditioned low pressure transducer FEATURES · Pressure ranges from 0...±2.5 "H2O (0...±6.4 cm H2O) to -20...120 cm H2O (custom calibrations available) · 1...6 V output · Output ratiometric to supply voltage · Precision temperature compensated and calibrated · Special calibrations for small volumes on request · EMC-proof SERVICE Scale: Non-corrosive, non-ionic working fluids, such as dry air and dry gases SPECIFICATIONS 1 cm 1 inch ELECTRICAL CONNECTION Maximum ratings Excitation voltage Output current Source Sink Output load capacitance Temperature limits Operating Storage Compensated Humidity (non-condensing) Proof pressure1 June 2006 / 567 7...16 V +Vs 10 mA 5 mA 10 nF -25 to +85°C -40 to +125°C -18 to +63°C 160PC...-PCB 7 V to 16 V (NOM 8.00 V) Vout V -Vs 0 - 95 %RH 350 mbar 1/6 www.sensortechnics.com 160PC...-PCB Series Fully signal conditioned low pressure transducer 161PC01D-PCB PERFORMANCE CHARACTERISTICS (unless otherwise noted, VS = 8.00 V, RL > 100 kΩ, tamb = 25°C) Characteristics Min. Operating pressure 0 Zero pressure offset 0.95 Span4 Typ. 1.00 Max. Unit -1.0 p si d 1.05 5.0 Full scale output 5.90 3 Thermal effects (-18 to +63°C) 6.00 ±1.0 Span ±1.0 Combined offset and span ±1.0 Non-linearity (BSL) Hysteresis and repeatability ±1.0 %FSS 20.0 mA 1 msec ±0.15 7 to 8 V and 8 to 9 V ±0.5 9 to 12 V ±2.0 Current consumption (no load) Response time Radiated, radio frequency electromagnetic field immunity (RFI), EN6100-4-3 grade 3, 80 to 1000 MHz, 80 % AMC (1 KHz) 162PC01D-PCB 6.10 Offset 2 Ratiometricity V 10 V/m PERFORMANCE CHARACTERISTICS (unless otherwise noted, VS = 8.00 V, RL > 100 kΩ, tamb = 25°C) Characteristics Min. Operating pressure 0 Zero pressure offset 0.95 Span4 Typ. 1.00 Unit 1.0 p si d 1.05 5.00 Full scale output 3 Thermal effects (-18 to +63°C) 5.90 6.00 6.10 ±1.0 Span ±1.0 Combined offset and span ±1.0 ±1.0 Hysteresis and repeatability Ratiometricity V Offset Non-linearity (BSL)2 %FSS ±0.15 7 to 8 V and 8 to 9 V ±0.5 9 to 12 V ±2.0 Current consumption (no load) Response time Radiated, radio frequency electromagnetic field immunity (RFI), EN6100-4-3 grade 3, 80 to 1000 MHz, 80 % AMC (1 KHz) 2/6 Max. 10 20.0 mA 1 msec V/m June 2006 / 567 www.sensortechnics.com 160PC...-PCB Series Fully signal conditioned low pressure transducer 163PC01D36-PCB PERFORMANCE CHARACTERISTICS (unless otherwise noted, VS = 8.00 V, RL > 100 kΩ, tamb = 25°C) Characteristics Min. Typ. Max. Unit +5 "H2O Operating pressure -5 Zero pressure offset 3.45 3.50 3.55 at -5"H2O 0.80 1.00 1.20 at +5"H2O 5.90 6.00 6.10 Output voltage 3 Thermal effects (+5 to +45°C) Offset ±1.0 Span ±1.0 Combined offset and span ±1.0 2 Non-linearity (BSL) Hysteresis and repeatability ±1.0 %FSS 20.0 mA 1 msec ±0.25 Ratiometricity 7 to 8 V and 8 to 9 V ±0.5 9 to 12 V ±2.0 Current consumption (no load) Response time Radiated, radio frequency electromagnetic field immunity (RFI), EN6100-4-3 grade 3, 80 to 1000 MHz, 80 % AMC (1 KHz) 164PC01D37-PCB V 10 V/m PERFORMANCE CHARACTERISTICS (unless otherwise noted, VS = 8.00 V, RL > 100 kΩ, tamb = 25°C) Characteristics Min. Operating pressure 0 Zero pressure offset 0.95 Span4 Typ. 1.00 Unit 10 "H2O 1.05 5.0 Full scale output 5.90 3 Thermal effects (+5 to +45°C) 6.00 6.10 ±1.0 Span ±1.0 Combined offset and span ±1.0 Hysteresis and repeatability Ratiometricity V Offset Non-linearity (BSL)2 ±1.0 %FSS 20.0 mA 1 msec ±0.25 7 to 8 V and 8 to 9 V ±0.5 9 to 12 V ±2.0 Current consumption (no load) Response time Radiated, radio frequency electromagnetic field immunity (RFI), EN6100-4-3 grade 3, 80 to 1000 MHz, 80 % AMC (1 KHz) June 2006 / 567 Max. 10 V/m 3/6 www.sensortechnics.com 160PC...-PCB Series Fully signal conditioned low pressure transducer 163PC01D75-PCB PERFORMANCE CHARACTERISTICS (unless otherwise noted, VS = 8.00 V, RL > 100 kΩ, tamb = 25°C) Characteristics Min. Typ. Max. Unit +2.5 "H2O Operating pressure -2.5 Zero pressure offset 3.45 3.50 3.55 at -2.5"H2O 0.80 1.00 1.20 at +2.5"H2O 5.90 6.00 6.10 Output 3 Thermal effects (+5 to +45°C) Offset ±1.25 Span ±1.25 Combined offset and span ±1.25 2 Non-linearity (BSL) Hysteresis and repeatability ±1.0 %FSS 20.0 mA 1 msec ±0.25 Ratiometricity 7 to 8 V and 8 to 9 V ±0.5 9 to 12 V ±2.0 Current consumption (no load) Response time Radiated, radio frequency electromagnetic field immunity (RFI), EN6100-4-3 grade 3, 80 to 1000 MHz, 80 % AMC (1 KHz) 164PC01D76-PCB V 10 V/m PERFORMANCE CHARACTERISTICS (unless otherwise noted, VS = 8.00 V, RL > 100 kΩ, tamb = 25°C) Characteristics Min. Operating pressure 0 Zero pressure offset 0.95 Span4 Typ. 1.00 Unit 5 "H2O 1.05 5.0 Full scale output 5.90 3 Thermal effects (+5 to +45°C) 6.00 6.10 ±1.25 Span ±1.25 Combined offset and span ±1.25 Hysteresis and repeatability Ratiometricity V Offset Non-linearity (BSL)2 ±1.0 %FSS 20.0 mA 1 msec ±0.25 7 to 8 V and 8 to 9 V ±0.5 9 to 12 V ±2.0 Current consumption (no load) Response time Radiated, radio frequency electromagnetic field immunity (RFI), EN6100-4-3 grade 3, 80 to 1000 MHz, 80 % AMC (1 KHz) 4/6 Max. 10 V/m June 2006 / 567 www.sensortechnics.com 160PC...-PCB Series Fully signal conditioned low pressure transducer 163PC01D48-PCB PERFORMANCE CHARACTERISTICS (unless otherwise noted, VS = 10.00 V, RL > 100 kΩ, tamb = 25°C) Characteristics Min. Operating pressure -20 Zero pressure offset 1.59 at -20 cm H2O Output at 120 cm H2O 3 Thermal effects (+5 to +45°C) Typ. 1.74 Unit 120 cm H2O 1.89 1.00 5.82 5.97 V 6.12 Offset ±1.0 Span ±1.0 Combined offset and span ±1.0 2 Non-linearity (BSL) Hysteresis and repeatability Ratiometricity Max. ±1.0 %FSS 20.0 mA 1 msec ±0.15 9 to 10 V and 10 to 11 V ±0.5 7 to 10 V and 11 to 12 V ±2.0 Current consumption (no load) Response time Radiated, radio frequency electromagnetic field immunity (RFI), EN6100-4-3 grade 3, 80 to 1000 MHz, 80 % AMC (1 KHz) 10 V/m Specification notes: 1. 2. 3. 4. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. Non-linearity - the maximum deviation of measured output at constant temperature, from "Best Straight Line" through three points (offset pressure, full scale pressure and 1/2 full scale pressure). Thermal effects tested and guaranteed in the specified temperature ranges relative to 25°C. All specifications shown are relative to 25°C. Span is the algebraic difference between lowest and highest specified pressure. June 2006 / 567 5/6 www.sensortechnics.com 160PC...-PCB Series Fully signal conditioned low pressure transducer OUTLINE DRAWING 30.0 port A (high pressure) 31.5 2 x 5.08 typ. 3 terminals 0.56 diam. 10.7 4.8 diam. 3,4 3.2 diam. 2 x mounting holes mass: 20 g 22.7 52.4 59.8 18.3 14.0 NOM 6.0 1 2 3 12.6 pin connection 1 +Vs 2 -Vs 3 Vout dimensions in mm ORDERING INFORMATION Operating pressure Part number 0 to -1 psid 161PC01D-PCB 0 to +1 psid 162PC01D-PCB -5 to +5 "H2O 163PC01D36-PCB 0 to +10 "H2O 164PC01D37-PCB -2.5 to +2.5 "H2O 163PC01D75-PCB 0 to +5 "H2O 164PC01D76-PCB -20 to +120 cm H2O 163PC01D48-PCB Custom calibrations available Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. 6/6 June 2006 / 567 www.sensortechnics.com