SENSORTECHNICS 423SC15D-PCB

140SC...-PCB / 420SC...-PCB Series
Signal conditioned precision pressure transducers
FEATURES
· 1 to 150 psi
absolute, gage or differential pressure
(custom calibrations available)
· 1...6 V or 4...20 mA output
· Internal supply regulation
· Precision temperature compensated
and calibrated
· Special calibrations for small
volumes on request
SERVICE
Scale:
Non-corrosive, non-ionic working fluids,
such as dry air and dry gases
SPECIFICATIONS
Maximum ratings
Supply voltage
140SC...-PCB
420SC...-PCB1
Maximum load current
140SC...-PCB only
Source
Sink
Temperature limits
Storage
Operating
Compensated
Lead temperature
(10 sec. soldering)
Humidity limits
Pressure inlets only
Proof pressure2
All 1 psi, 3 psi, 5 psi devices
All 15 psi devices
All 30 psi devices
All 100 psi devices
All 150 psi devices
March 2006 / 002
1 cm
1 inch
ELECTRICAL CONNECTION
7...24 V
12...36 V
20 mA
10 mA
1...6 V output version
+Vs
7 V to 24 V
Vout
140SC...PCB
V
-55 to 100°C
-40 to 85°C
0 to 70°C
300°C
-Vs
4...20 mA output version
+Vs
0 - 100 %RH
20 psi
30 psi
60 psi
150 psi
200 psi
420SC...PCB
-Vs
12 V to 36 V
V
RL
GND
1/6
www.sensortechnics.com
140SC...-PCB / 420SC...-PCB Series
Signal conditioned precision pressure transducers
PERFORMANCE CHARACTERISTICS
1 - 6 V output version (unless otherwise noted VS = 8 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Operating pressure
vacuum gage devices3
differential devices4
absolute devices5
pressure/vacuum devices4
Zero pressure offset
Full scale span6
Min.
141SC01G-PCB
141SC05G-PCB
141SC15G-PCB
141SC30G-PCB
141SC100G-PCB
142SC01D-PCB
142SC05D-PCB
142SC15D-PCB
142SC30D-PCB
142SC100D-PCB
142SC150D-PCB
142SC15A-PCB
142SC30A-PCB
142SC100A-PCB
143SC01D-PCB
143SC03D-PCB
143SC05D-PCB
143SC15D-PCB
141SC.../142SC...-PCB
143SC...-PCB
141SC.../142SC...-PCB
143SC...-PCB
Full scale output
Output at lowest specified pressure
Non-linearity and hysteresis (BSL)7
Thermal effects8
Combined offset and span (0 to 70°C)
Long term stability9
Response time (10 to 90%)
Power supply rejection rate
2/6
-1
-5
-15
-30
-100
0
0
0
0
0
0
0
0
0
-1
-2.5
-5
-15
0.95
3.45
4.95
2.45
5.90
Typ.
Max.
1.00
3.50
5.00
2.50
6.00
0
0
0
0
0
1
5
15
30
100
150
15
30
100
1
2.5
5
15
1.05
3.55
5.05
2.55
6.10
143SC...-PCB
1.00
all 1 psi devices
all others
0.1
±1.5
±0.5
±0.1
Offset
Span
0.1
0.05
0.03
0.5
±3.0
±1.0
Unit
p si g
psid(g)
p si a
psid(g)
V
%FSO
ms
%FSO/V
March 2006 / 002
www.sensortechnics.com
140SC...-PCB / 420SC...-PCB Series
Signal conditioned precision pressure transducers
PERFORMANCE CHARACTERISTICS
4 - 20 mA output version (unless otherwise noted VS = 15 V, RL = 100 Ω, tamb = 25°C)
Characteristics
Min.
Operating pressure
differential devices4
420SC01D-PCB
420SC05D-PCB
420SC15D-PCB
420SC30D-PCB
420SC100D-PCB
420SC150D-PCB
420SC15A-PCB
420SC30A-PCB
420SC100A-PCB
423SC01D-PCB
423SC03D-PCB
423SC05D-PCB
423SC15D-PCB
420SC...-PCB
423SC...-PCB
420SC...-PCB
423SC...-PCB
absolute devices5
pressure/vacuum devices4
Zero pressure offset
Full scale span6
Full scale output
Output at lowest specified pressure
423SC...-PCB
7
Non-linearity and hysteresis (BSL)
Thermal effects8
Combined offset and span
(0 to 70°C)
all 1 psi devices
all others
(-40 to 0°C, 70 to 100°C)
Repeatability
Long term stability9
4.0
12.0
16.0
8.0
20.0
Max.
1
5
15
30
100
150
15
30
100
1
2.5
5
15
4.1
12.1
16.2
8.1
Unit
psid(g)
p si a
p si d
mA
4.0
±0.1
±0.5
±1.5
±0.5
±2.0
±0.1
±3.0
±1.5
%FSO
±0.1
Output noise
Response time (10 to 90%)
Power supply rejection rate
0
0
0
0
0
0
0
0
0
-1
-2.5
-5
-15
3.9
11.9
15.8
7.9
Typ.
±0.04
Offset
Span
0.1
0.05
0.03
ms
%FSO/V
Specification notes:
1. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the
load limitation diagram.
2. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element.
3. The output signal of all 141SC...-PCB devices is proportional to the vacuum applied to port B, relative to port A, e. g. the output
signal increases when pressure is applied to port A relative to port B.
4. The output signal of all 142SC...D-PCB and 143SC...D-PCB devices is proportional to the pressure applied to port B, relative to
port A, e.g. the output signal increases when vacuum is applied to port A relative to port B.
5. The output signal of all 142SC...A-PCB is proportional to the pressure applied to port A.
6. Full scale span is the algebraic difference between the positive full scale output and the zero pressure offset.
7. Non-linearity refers to the Best Straight Line fit measured for offset pressure, full scale pressure and 1/2 full scale pressure.
8. Thermal effects tested and guaranteed from 0 - 70°C relative to 25°C. All specifications shown are relative to 25°C.
9. Change in output after one year or 1 million pressure cycles.
March 2006 / 002
3/6
www.sensortechnics.com
140SC...-PCB / 420SC...-PCB Series
Signal conditioned precision pressure transducers
OUTPUT CHARACTERISTICS
1 - 6 V output versions
Vacuum gage devices
141SC...-PCB
1 - 6 V output versions
Differential devices
142SC...-PCB
6
6
Vout
5
V
Vout
5
V
4
4
3
3
2
2
1
1
-100
0
-80
-60
-40
-20
0
% full scale pressure (vacuum)
1 - 6 V output versions
Pressure/vacuum devices
143SC...-PCB
20
40
60
80
100
% full scale pressure
4 - 20 mA output versions
Differential devices
420SC...-PCB
20
6
Vout
5
V
Iout
16
mA
4
12
3.5V
3
8
2
4
1
0
-100
4/6
-50
0
50
100
% full scale pressure
0
20
40
60
80
100
% full scale pressure
March 2006 / 002
www.sensortechnics.com
140SC...-PCB / 420SC...-PCB Series
Signal conditioned precision pressure transducers
OUTPUT CHARACTERISTICS
LOAD LIMITATION
4 - 20 mA output versions
Pressure/vacuum devices
423SC...-PCB
4 - 20 mA output versions
20
1200
Ohm
1000
Iout
16
mA
800
12
600
operating
range
8
400
4
200
-100
-50
0
50
100
% full scale pressure
0
10
20
30 V
Vsupply
OUTLINE DRAWING
5
30.0
port A
30.5
3 terminals
0.56 diam.
4.8
diam.
3.5 diam.
2 x mounting holes
March 2006 / 002
22.7
3,4
port B
mass: 20 g
2 x 5.08 typ.
9.1
10.7
52.4
59.8
18.3
14.0
NOM 6.0
Pin connection
Connection
1 - 6 V 4 - 20 mA
version
Pin
version
1
+Vs
NC
2
-Vs
-Vs
3
Vout
+Vs
1
2
3
12.6
dimensions in mm
5/6
www.sensortechnics.com
140SC...-PCB / 420SC...-PCB Series
Signal conditioned precision pressure transducers
ORDERING INFORMATION
Part number
Operating pressure
Vacuum gage devices
1...6 V output
4...20 mA output
0 to -1 psig
141SC01G-PCB
---
0 to -5 psig
141SC05G-PCB
---
0 to -15 psig
141SC15G-PCB
---
0 to -30 psig
141SC30G-PCB
---
0 to -100 psig
141SC100G-PCB
---
0 to 1 psid(g)
142SC01D-PCB
420SC01D-PCB
0 to 5 psid(g)
142SC05D-PCB
420SC05D-PCB
0 to 15 psid(g)
142SC15D-PCB
420SC15D-PCB
0 to 30 psid(g)
142SC30D-PCB
420SC30D-PCB
0 to 100 psid(g)
142SC100D-PCB
420SC100D-PCB
0 to 150 psid(g)
142SC150D-PCB
420SC150D-PCB
0 to 15 psia
142SC15A-PCB
420SC15A-PCB
0 to 30 psia
142SC30A-PCB
420SC30A-PCB
0 to 100 psia
142SC100A-PCB
420SC100A-PCB
0 to ±1 psid(g)
143SC01D-PCB
423SC01D-PCB
0 to ±2.5 psid(g)
143SC03D-PCB
423SC03D-PCB
0 to ±5 psid(g)
143SC05D-PCB
423SC05D-PCB
0 to ±15 psid(g)
143SC15D-PCB
423SC15D-PCB
Differential/gage devices
Absolute devices
Pressure/vacuum devices
Custom calibrations available
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the
application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
6/6
March 2006 / 002
www.sensortechnics.com